Gastrointestinal bleeding and pro-angiogenic shift in the angiopoietin axis with continuous flow left ventricular assist device implantation

被引:0
|
作者
Edwards, Adam L. [1 ]
Wilcox, C. Mel [1 ]
Beasley, Mark [2 ]
Pamboukian, Salpy V. [1 ,3 ,4 ]
Mannon, Peter [1 ,4 ]
Peter, Shajan [5 ]
机构
[1] Univ Alabama Birmingham, Sch Med, Dept Med, Div Gastroenterol & Hepatol, Birmingham, AL USA
[2] Univ Alabama Birmingham, Sch Publ Hlth, Birmingham, AL USA
[3] Univ Alabama Birmingham, Sch Med, Dept Med, Div Cardiovasc Dis, Birmingham, AL USA
[4] Univ Nebraska Med Ctr, Coll Med, Dept Internal Med, Div Gastroenterol & Hepatol, Omaha, NE USA
[5] Univ Alabama Birmingham, Sch Med, Dept Med, Div Gastroenterol & Hepatol, BDB 389,1720 2nd Ave S, Birmingham, AL 35294 USA
关键词
Gastrointestinal bleeding; Left ventricular assist device; Angiopoietin; VON-WILLEBRAND SYNDROME; ARTERIOVENOUS-MALFORMATIONS; SHEAR-STRESS; RISK; PULSATILITY; HYPOXIA;
D O I
10.1016/j.amjms.2023.07.003
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Gastrointestinal bleeding (GIB) affects up to 40% of continuous-flow left ventricular assist device (CF-LVAD) recipients. A higher risk of GIB is seen in CF-LVAD recipients with lower device pulsatility without a known mechanism. One hypothesis is that the novel hemodynamics in CF-LVAD recipients affect angiogenesis signaling. We aimed to (1) measure serum levels of angiopoietin (Ang)-1, Ang-2, and VEGF-A in CF-LVAD recipients with and without GIB and in healthy controls and (2) evaluate correlations of those levels with hemodynamics. Methods: We recruited 12 patients with CF-LVADs (six who developed GIB after device implantation) along with 12 age-matched controls without heart failure or GIB and measured Ang-1, Ang-2, and VEGF-A levels in serum samples from each patient. Results: CF-LVAD recipients had significantly higher Ang-2 and lower Ang-1 levels compared to controls with no difference in VEGF-A levels. CF-LVAD recipients with GIB had lower Ang-1 levels than those without GIB. There were trends for pulse pressure to be positively correlated with Ang-1 levels and negatively correlated with Ang-2 levels in CF-LVAD recipients with no correlation observed in healthy controls. Conclusion: CF-LVAD recipients demonstrated a shift toward a pro-angiogenic phenotype in the angiopoietin axis that is significantly associated with GIB and may be linked to low pulse pressure.
引用
收藏
页码:278 / 285
页数:8
相关论文
共 50 条
  • [1] Gastrointestinal bleeding on continuous-flow left ventricular assist device therapy
    Hammer, Yoav
    Bitar, Abbas
    Aaronson, Keith D.
    ESC HEART FAILURE, 2023, 10 (04): : 2214 - 2224
  • [2] The Predicament of Gastrointestinal Bleeding in Patients With a Continuous-Flow Left Ventricular Assist Device Pathophysiology, Evaluation, and Management
    Berg, Dana
    Lebovics, Edward
    Kai, Masashi
    Spielvogel, David
    CARDIOLOGY IN REVIEW, 2019, 27 (05) : 222 - 229
  • [3] Continuous-Flow Left Ventricular Assist Device-Related Gastrointestinal Bleeding
    Kim, Ju H.
    Brophy, Donald F.
    Shah, Keyur B.
    CARDIOLOGY CLINICS, 2018, 36 (04) : 519 - +
  • [4] Gastrointestinal Bleeding During Continuous-Flow Left Ventricular Assist Device Support State of the Field
    Kataria, Rachna
    Jorde, Ulrich P.
    CARDIOLOGY IN REVIEW, 2019, 27 (01) : 8 - 13
  • [5] Pharmacotherapeutic Management of Gastrointestinal Bleeding in Patients with Continuous-Flow Left Ventricular Assist Devices
    Sieg, Adam C.
    Moretz, Jeremy D.
    Horn, Edward
    Jennings, Douglas L.
    PHARMACOTHERAPY, 2017, 37 (11): : 1432 - 1448
  • [6] Gastrointestinal Bleeding during Continuous-Flow Left Ventricular Assist Device Support is Associated with Lower Rates of Cardiac Transplantation
    Holley, Christopher T.
    Harvey, Laura
    Roy, Samit S.
    Cogswell, Rebecca
    Eckman, Peter
    Liao, Kenneth
    John, Ranjit
    ASAIO JOURNAL, 2015, 61 (06) : 635 - 639
  • [7] Characterization and timing of gastrointestinal bleeding in continuous flow left ventricular assist device recipients
    Kapuria, Devika
    Khumri, Taiyeb
    Shamim, Shariq
    Surana, Pallavi
    Khan, Salman
    Al-Khalisi, Nabil
    Aggarwal, Sanjeev
    Koh, Christopher
    Chhabra, Rajiv
    HELIYON, 2020, 6 (09)
  • [8] Risk Factors of Gastrointestinal Bleeding After Continuous Flow Left Ventricular Assist Device
    Balcioglu, Ozlem
    Kemal, Hatice S.
    Ertugay, Serkan
    Ozturk, Pelin
    Engin, Yaprak
    Nalbantgil, Sanem
    Engin, Cagatay
    Yagdi, Tahir
    Ozbaran, Mustafa
    ASAIO JOURNAL, 2018, 64 (04) : 458 - 461
  • [9] A reappraisal of the pharmacologic management of gastrointestinal bleeding in patients with continuous flow left ventricular assist devices
    Littlefield, Audrey J.
    Jones, Gregory
    Ciolek, Alana M.
    Yuzefpolskaya, Melana
    Jennings, Douglas L.
    HEART FAILURE REVIEWS, 2021, 26 (02) : 277 - 288
  • [10] Bleeding Complication Rates Are Higher in Females after Continuous-Flow Left Ventricular Assist Device Implantation
    Yavar, Zubin
    Cowger, Jennifer A.
    Moainie, Sina L.
    Salerno, Christopher T.
    Ravichandran, Ashwin K.
    ASAIO JOURNAL, 2018, 64 (06) : 748 - 753