Regulation of multi-area power system load frequency in presence of V2G scheme

被引:5
|
作者
Hussein, Mahmoud M. [1 ]
Mohamed, Tarek Hassan [1 ]
Mahmoud, Mohamed Metwally [1 ]
Aljohania, Mansour [2 ]
Mosaad, Mohamed I. [2 ,3 ]
Hassan, Ammar M. [4 ]
机构
[1] Aswan Univ, Fac Energy Engn, Dept Elect Engn, Aswan, Egypt
[2] Royal Commiss Yanbu Colleges & Inst, Yanbu Ind Coll YIC, Elect & Elect Engn Technol Dept, Yanbu, Saudi Arabia
[3] Damietta Univ, Fac Engn, Elect Engn Dept, Dumyat, Egypt
[4] Arab Acad Sci Technol & Maritime Transport, South Valley Branch, Aswan, Egypt
来源
PLOS ONE | 2023年 / 18卷 / 09期
关键词
ELECTRIC VEHICLES; PERFORMANCE;
D O I
10.1371/journal.pone.0291463
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The integration of renewable sources (RSs) and the widespread deployment of electric vehicles (EVs) has transitioned from a luxury to a necessity in modern power systems. This results from the sharp increase in electric power demand and public awareness of switching to green energy. However, in addition to load fluctuations and changes in system parameters, these RSs and EVs negatively impact the load frequency (LF). This work presents a LF control for a modern multi-area power system incorporating photovoltaic (PV) and EV chargers. The proposed controller primarily utilizes EV chargers within modern power systems. This approach offers the advantage of using the already present components instead of introducing new ones. The proposed controller comprises the ecological optimization approach (ECO) and the integral controller (I). Both of these components are designed for autonomous vehicle-to-grid (V2G) devices. The proposed control technique is applied to a three-area power system, where the V2G scheme is located in Area-1. Variations in the load, PV power generated, and system parameters are considered to evaluate the effectiveness of the proposed (I+ECO+V2G) controller for controlling the LF. To assess the performance of the proposed I+ECO+V2G system, a comparative analysis is conducted to compare its performance with both the I+ECO system and the standard I-controller. The simulation findings demonstrate that implementing the I+ECO and the proposed I+ECO+V2G strategies results in enhanced system stability and decreased LF fluctuations compared to the conventional I-control approach. Furthermore, while comparing the I+ECO control technique to the suggested control strategy I+ECO+V2G, it was seen that the latter reaches steady state values more quickly. The results validate the robustness and effectiveness of the proposed controller in mitigating the impacts of load disturbances, uncertainties, and nonlinearities within the system. These simulations were performed using MATLAB/SIMULINK. To validate the outcomes of the simulation results, an experimental setup consisting of a real-time dSPACE DS1103 connected to another PC via QUARC pid_e data acquisition card was used. The experimental findings have substantiated the accuracy of the simulation findings about the superiority of the I+ECO+V2G methodology compared to both the I+ECO and I-control methodologies concerning system performance and LF control.
引用
收藏
页数:24
相关论文
共 50 条
  • [1] Frequency regulation controller for multi-area interconnected power system
    Malek, Sajjad
    Khodabakhshian, Amin
    Hooshmand, Rahmat-Allah
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2024, 18 (17) : 2776 - 2792
  • [2] Electric vehicle participation for optimized load frequency control in a multi-area restructured power system
    Thorat, Riddhi
    Bhatt, Praghnesh
    INTERNATIONAL JOURNAL OF MODELLING AND SIMULATION, 2024,
  • [3] Load frequency regulation of interconnected muli-source multi-area power system with penetration of electric vehicles aggregator model
    Jameel, Ahlam
    Gulzar, Muhammad Majid
    ELECTRICAL ENGINEERING, 2023, 105 (06) : 3951 - 3968
  • [4] Load frequency regulation of interconnected muli-source multi-area power system with penetration of electric vehicles aggregator model
    Ahlam Jameel
    Muhammad Majid Gulzar
    Electrical Engineering, 2023, 105 : 3951 - 3968
  • [5] Autonomous Frequency Regulation Control of V2G(Vehicle-to-Grid) System
    Han, Huachun
    Huang, Di
    Liu, Dan
    Li, Qiang
    2017 29TH CHINESE CONTROL AND DECISION CONFERENCE (CCDC), 2017, : 5826 - 5829
  • [6] Decentralized PID load frequency control for perturbed multi-area power systems
    Saxena, Sahaj
    Hote, Yogesh V.
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2016, 81 : 405 - 415
  • [7] Reliability assessment of frequency regulation service provided by V2G
    Manjunath, Archana
    2015 NORTH AMERICAN POWER SYMPOSIUM (NAPS), 2015,
  • [8] A New Load Frequency Control Method of Multi-Area Power System via the Viewpoints of Port-Hamiltonian System and Cascade System
    Cai, Liangcheng
    He, Zhengyou
    Hu, Haitao
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2017, 32 (03) : 1689 - 1700
  • [9] Research on Modeling of Microgrid Load Frequency Control Based on V2G Technology
    Xiong, Zhonghao
    Liu, Shoubao
    Fang, Yuan
    Li, Yonglong
    Yang, Jian
    2020 5TH INTERNATIONAL CONFERENCE ON MECHANICAL, CONTROL AND COMPUTER ENGINEERING (ICMCCE 2020), 2020, : 617 - 622
  • [10] Robust overlapping load frequency output feedback control of multi-area interconnected power systems
    Ahmadi, Adel
    Aldeen, Mohammad
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2017, 89 : 156 - 172