Numerical simulation of wind-induced load on evacuated tube solar water heaters

被引:4
作者
Liu, Y. J. [1 ]
Fu, J. Y. [1 ]
Huang, J. Q. [1 ]
Wang, J. J. [1 ]
He, Y. C. [1 ]
机构
[1] Guangzhou Univ, Res Ctr Wind Engn & Engn Vibrat, Guangzhou, Peoples R China
基金
中国国家自然科学基金;
关键词
Solar water heater; Wind effect; Numerical simulation; Large Eddy Simulation; ENERGY; SYSTEMS; FLOW;
D O I
10.1016/j.solener.2023.05.027
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Solar Water Heater (SWH) has been used as a traditional device in many countries and regions for collecting solar energy. Unfortunately, there are many wind-induced accidents of SWHs, owing to insufficient consideration of wind-resistant design and installation. To better promote the safe use of SWHs, characteristics of wind load acting on them should be clarified thoroughly as far as possible. In this article, a systematic study is carried out by numerical simulation based on computational fluid dynamics (CFD) to analyze the effects of the tilt angle and density of evacuated tube collectors (ETC) as well as wind direction on the aerodynamic characteristics of SWH. Results show that the wind-resistance performance of SWH decreases significantly for wind flows blowing from 0 degrees and 180 degrees due to the influence of aerodynamic characteristics of its main components. When the ETC is located upstream of the water tank, the arrangement form of the tubes will have an impact on the aerodynamic char-acteristics of the SHW. A lower porosity of ETC can increase wind load on the weak region of water tank and the windward face of vertical supports, it can also increase the bending moment of inclined supports significantly. By contrast, lower tilt angles of ETC are more beneficial to the wind resistance of SHW, although they can result in an increase of the local wind suction on water tank.
引用
收藏
页码:147 / 155
页数:9
相关论文
共 50 条
[41]   Numerical simulation of solar wind energy towers [J].
Hijazi, L. ;
Fayssal, I. A. ;
Darwish, M. ;
Moukalled, F. .
NUMERICAL HEAT TRANSFER PART A-APPLICATIONS, 2017, 72 (10) :780-805
[42]   System Performance of U-Tube and Heat Pipe Solar Water Heaters [J].
Ong, K. S. ;
Tong, W. L. .
JOURNAL OF APPLIED SCIENCE AND ENGINEERING, 2012, 15 (02) :105-110
[43]   Numerical simulation of non-Gaussian wind load [J].
YE JiHong DING JingHu LIU ChuanYan Key Laboratory of Concrete and Prestressed Concrete Structures of Ministry of EducationSoutheast UniversityNanjing China .
Science China(Technological Sciences), 2012, (11) :3057-3069
[44]   Numerical simulation of non-Gaussian wind load [J].
JiHong Ye ;
JingHu Ding ;
ChuanYan Liu .
Science China Technological Sciences, 2012, 55 :3057-3069
[45]   Efficiency of evacuated tube solar collector using WO3/Water nanofluid [J].
Sharafeldin, M. A. ;
Grof, Gyula .
RENEWABLE ENERGY, 2019, 134 :453-460
[46]   Numerical simulation of non-Gaussian wind load [J].
Ye JiHong ;
Ding JingHu ;
Liu ChuanYan .
SCIENCE CHINA-TECHNOLOGICAL SCIENCES, 2012, 55 (11) :3057-3069
[47]   A numerical simulation method in time domain to study wind-induced excitation of traffic signal structures and its mitigation [J].
Jafari, Mohammad ;
Sarkar, Partha P. ;
Alipour, Alice A. .
JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2019, 193
[48]   Evacuated tube solar collector performance using CeO2/water nanofluid [J].
Sharafeldin, M. A. ;
Grof, Gyula .
JOURNAL OF CLEANER PRODUCTION, 2018, 185 :347-356
[49]   Failure investigation of a solar tracker due to wind-induced torsional galloping [J].
Valentin, David ;
Valero, Carme ;
Egusquiza, Monica ;
Presas, Alexandre .
ENGINEERING FAILURE ANALYSIS, 2022, 135
[50]   Evacuated tube collectors: A notable driver behind the solar water heater industry in China [J].
Qiu, Shoufeng ;
Ruth, Matthias ;
Ghosh, Sanchari .