Dynamic Time Warping Based Pilot Protection Algorithm for AC and HVDC Transmission Lines

被引:3
|
作者
Manassero, Giovanni [1 ]
Tiferes, Rodrigo Rozenblit [1 ]
机构
[1] Univ Sao Paulo, Dept Engn Energia & Automacao Elect, Escola Politecn, BR-05508010 Sao Paulo, Brazil
关键词
Power transmission lines; line commutated converter; voltage source converter; pilot protection; dynamic time warping; DOMAIN DIFFERENTIAL PROTECTION; SCHEME;
D O I
10.1109/ACCESS.2023.3281500
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper presents a pilot protection algorithm for alternating (ac) and direct current (dc) transmission lines, the last in the line commutated converter and voltage source converter topologies. The main contribution of this research lies, in this context, in the development of a protection method for lines of different natures. This method relies on the dynamic time warping (DTW) technique. The solution is attractive as it does not require any line or system parameters and works only with current samples. For ac lines, the algorithm uses DTW to evaluate the line terminals phase currents' and the zero-sequence components' similarities and detect faults. In turn, for dc lines, the method employs DTW technique to evaluate the similarities of cross-currents between poles and terminals and identify internal dc faults. The authors tested the algorithm for each line topology through several fault simulations, also considering the challenging conditions of high impedance internal faults, sampled noises, misalignment between samples, current transformer saturation, power swing, and internal fault with outfeed. This solution was also tested against field-recorded data in existing lines, and the resulting trip times were compared with the ones of the actual protection devices. All results indicate that this solution yields a rapid, effective, secure, and dependable protection.
引用
收藏
页码:56846 / 56857
页数:12
相关论文
共 50 条
  • [31] Effects of VSC based HVDC system on distance protection of transmission lines
    Alam, Mohammad Meraj
    Leite, Helder
    Liang, Jun
    Carvalho, Adriano da Silva
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2017, 92 : 245 - 260
  • [32] Pilot protection method of half-wavelength AC transmission lines based on random matrix theory
    Tang, Yutao
    Shu, Hongchun
    He, Kai
    Wang, Guanxue
    Liu, Litao
    Han, Yiming
    Dai, Yue
    ELECTRIC POWER SYSTEMS RESEARCH, 2023, 224
  • [33] Post-measurement simulation-based pilot protection of AC transmission lines in wind farms
    Shu, Hongchun
    Guan, Cheng
    Dai, Yue
    Tang, Yutao
    ELECTRIC POWER SYSTEMS RESEARCH, 2025, 241
  • [34] Pilot protection scheme for transmission line of a hybrid HVDC system based on polarity characteristics of current and voltage fault components
    Wang, Yanting
    Zhang, Baohui
    Cheng, Shaojie
    JOURNAL OF ENGINEERING-JOE, 2019, (16): : 820 - 825
  • [35] Pilot protection for hybrid multi-terminal HVDC transmission lines based on Euclidean distance between differential current and distributed capacitance current
    Chu, Beiyu
    Li, Haifeng
    Liang, Yuansheng
    Zhang, Qixuan
    Peng, Guangqiang
    Wang, Gang
    ELECTRIC POWER SYSTEMS RESEARCH, 2023, 224
  • [36] A novel transient directional pilot protection principle based on sequential overlapping derivative transform for AC transmission lines
    Wang, Bingran
    Wang, Zengping
    Wang, Zhaochen
    Wang, Tong
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2023, 17 (01) : 128 - 145
  • [37] A novel pilot differential protection for HVDC transmission line based on the differential voltage
    Zhang, Fengming
    Han, Ke
    Yu, Xiaohu
    Wu, Jiayi
    Chen, Yu
    Wen, Minghao
    ENERGY REPORTS, 2023, 9 : 680 - 686
  • [38] A novel pilot differential protection for HVDC transmission line based on the differential voltage
    Zhang, Fengming
    Han, Ke
    Yu, Xiaohu
    Wu, Jiayi
    Chen, Yu
    Wen, Minghao
    ENERGY REPORTS, 2023, 9 : 680 - 686
  • [39] Transient numerical calculation and differential protection algorithm for HVDC transmission lines based on a frequency-dependent parameter model
    Chu, Xu
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2019, 108 : 107 - 116
  • [40] A pilot protection scheme based on high-frequency transient current waveform similarity for AC lines connected to HVDC inverter station
    Duan, Jiandong
    Song, Wenqiang
    Du, Xiaotong
    Zhao, Yuhang
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2024, 18 (07) : 1404 - 1420