Computed tomography-based measurements of normative liver and spleen volumes in children

被引:3
|
作者
Alves, Vinicius de Padua V. [1 ]
Dillman, Jonathan R. [1 ,2 ]
Somasundaram, Elanchezhian [1 ]
Taylor, Zachary P. [1 ]
Brady, Samuel L. [1 ,2 ]
Zhang, Bin [3 ,4 ]
Trout, Andrew T. [1 ,2 ,4 ]
机构
[1] Cincinnati Childrens Hosp Med Ctr, Dept Radiol, 3333 Burnet Ave,Kasota Bldg MLC 5031, Cincinnati, OH 45229 USA
[2] Univ Cincinnati, Coll Med, Dept Radiol, Cincinnati, OH 45221 USA
[3] Cincinnati Childrens Hosp Med Ctr, Div Biostat & Epidemiol, Cincinnati, OH USA
[4] Univ Cincinnati, Coll Med, Dept Pediat, Cincinnati, OH 45221 USA
关键词
Children; Computed tomography; Liver; Normative; Segmentation; Spleen; Volume; SPLENIC VOLUME; CT; POPULATION; FORMULA; VALUES; ADULTS; SIZE; US;
D O I
10.1007/s00247-022-05551-z
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Background Quantification of organ size has utility in clinical care and research for diagnostics, prognostics and surgical planning. Volumetry is regarded as the best measure of organ size and change in size over time. Scarce reference values exist for liver and spleen volumes in healthy children. Objective To report liver and spleen volumes for a sample of children defined by manual segmentation of contrast-enhanced CT images with the goal of defining normal values and thresholds that might indicate disease. Materials and methods This retrospective study included clinically acquired contrast-enhanced CTs of the abdomen/pelvis for children and adolescents imaged between January 2018 and July 2021. Liver and spleen volumes were derived through manual segmentation of CTs reconstructed at 2.5-, 3- or 5-mm slice thickness. A subset of images (5%, n=16) was also segmented using 0.5-mm slice thickness reconstructions to define agreement based on image slice thickness. We used Pearson correlation and multivariable regression to assess associations between organ volumes and patient characteristics. We generated reference intervals for the 5th, 25th, 50th (median), 75th and 95th percentiles for organ volumes as a function of age and weight using quantile regression models. Finally, we calculated Bland-Altman plots and intraclass correlation coefficients (ICC) to quantify agreement. Results We included a total of 320 children (mean age +/- standard deviation [SD] = 9 +/- 4.6 years; mean weight 38.1 +/- 18.8 kg; 160 female). Liver volume ranged from 340-2,002 mL, and spleen volume ranged from 28-480 mL. Patient weight (kg) (beta=12.5), age (months) (beta=1.7) and sex (female) (beta = -35.3) were independent predictors of liver volume, whereas patient weight (kg) (beta=2.4) and age (months) (beta=0.3) were independent predictors of spleen volume. There was excellent absolute agreement (ICC=0.99) and minimal absolute difference (4 mL) in organ volumes based on reconstructed slice thickness. Conclusion We report reference liver and spleen volumes for children without liver or spleen disease. These results provide reference ranges and potential thresholds to identify liver and spleen size abnormalities that might reflect disease in children.
引用
收藏
页码:378 / 386
页数:9
相关论文
共 50 条
  • [21] Computerized tomography-based anatomic description of the porcine liver
    Bekheit, Mohamed
    Bucur, Petru O.
    Wartenberg, Mylene
    Vibert, Eric
    JOURNAL OF SURGICAL RESEARCH, 2017, 210 : 223 - 230
  • [22] Influence of Scan Resolution, Thresholding, and Reconstruction Algorithm on Computed Tomography-Based Kinematic Measurements
    Tan, Christopher John
    Parr, William C. H.
    Walsh, William R.
    Makara, Mariano
    Johnson, Kenneth A.
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2017, 139 (10):
  • [23] Comparison of cephalometric measurements and cone-beam computed tomography-based measurements of palatal bone thickness
    Kim, Young-Jae
    Lim, Sung-Hoon
    Gang, Sung-Nam
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2014, 145 (02) : 165 - 172
  • [24] Computed tomography-based measurements associated with rapid lung function decline in severe asthma
    Sim, Da Woon
    Choi, Sanghun
    Jeong, Jinyoung
    Lee, Suh-Young
    Nam, Young-Hee
    Kim, Byung-Keun
    Lee, Young-Soo
    Shim, Ji-Su
    Yang, Min-Suk
    Kim, Min-Hye
    Kim, So Ri
    Koh, Young-Il
    Kim, Sang-Heon
    Park, Heung-Woo
    ANNALS OF ALLERGY ASTHMA & IMMUNOLOGY, 2025, 134 (03) : 306 - 314.e5
  • [25] Effect of food intake on liver and spleen volume: Assessment with single photon emission computed tomography
    Roshdy, MSE
    Larsson, SA
    Kimiaei, S
    Jacobsson, H
    ACADEMIC RADIOLOGY, 1997, 4 (03) : 193 - 196
  • [26] The evaluation of non-invasive multi-slice spiral computed tomography-based indices for the diagnosis and prognosis prediction of liver cirrhosis
    Feng, Ling Mei
    Lei, Shu Juan
    Zeng, Xin
    Wang, Pei Qin
    Chen, Ru Tan
    Wang, Jian
    Sheng, Xia
    Shi, Pei Mei
    Yuan, Zong Li
    Xie, Wei Fen
    JOURNAL OF DIGESTIVE DISEASES, 2017, 18 (08) : 472 - 479
  • [27] Computed tomography-based volumetric tool for standardized measurement of the maxillary sinus
    Giacomini, Guilherme
    Menegatti Pavan, Ana Luiza
    Carrasco Altemani, Joao Mauricio
    Duarte, Sergio Barbosa
    Castelo Branco Fortaleza, Carlos Magno
    de Arruda Miranda, Jose Ricardo
    de Pina, Diana Rodrigues
    PLOS ONE, 2018, 13 (01):
  • [28] Deep Learning Algorithm for Automated Segmentation and Volume Measurement of the Liver and Spleen Using Portal Venous Phase Computed Tomography Images
    Ahn, Yura
    Yoon, Jee Seok
    Lee, Seung Soo
    Suk, Heung-Il
    Son, Jung Hee
    Sung, Yu Sub
    Lee, Yedaun
    Kang, Bo-Kyeong
    Kim, Ho Sung
    KOREAN JOURNAL OF RADIOLOGY, 2020, 21 (08) : 987 - 997
  • [29] Computed tomography measurements of the normal and the pathologic cochlea in children
    Natacha Teissier
    Thierry Van Den Abbeele
    Guy Sebag
    Monique Elmaleh-Berges
    Pediatric Radiology, 2010, 40 : 275 - 283
  • [30] Postoperative computed tomography-based control of syndesmotic screws
    Schwarz N.
    Köfer E.
    European Journal of Trauma, 2005, 31 (3): : 266 - 270