Computed tomography-based measurements of normative liver and spleen volumes in children

被引:5
作者
Alves, Vinicius de Padua V. [1 ]
Dillman, Jonathan R. [1 ,2 ]
Somasundaram, Elanchezhian [1 ]
Taylor, Zachary P. [1 ]
Brady, Samuel L. [1 ,2 ]
Zhang, Bin [3 ,4 ]
Trout, Andrew T. [1 ,2 ,4 ]
机构
[1] Cincinnati Childrens Hosp Med Ctr, Dept Radiol, 3333 Burnet Ave,Kasota Bldg MLC 5031, Cincinnati, OH 45229 USA
[2] Univ Cincinnati, Coll Med, Dept Radiol, Cincinnati, OH 45221 USA
[3] Cincinnati Childrens Hosp Med Ctr, Div Biostat & Epidemiol, Cincinnati, OH USA
[4] Univ Cincinnati, Coll Med, Dept Pediat, Cincinnati, OH 45221 USA
关键词
Children; Computed tomography; Liver; Normative; Segmentation; Spleen; Volume; SPLENIC VOLUME; CT; POPULATION; FORMULA; VALUES; ADULTS; SIZE; US;
D O I
10.1007/s00247-022-05551-z
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Background Quantification of organ size has utility in clinical care and research for diagnostics, prognostics and surgical planning. Volumetry is regarded as the best measure of organ size and change in size over time. Scarce reference values exist for liver and spleen volumes in healthy children. Objective To report liver and spleen volumes for a sample of children defined by manual segmentation of contrast-enhanced CT images with the goal of defining normal values and thresholds that might indicate disease. Materials and methods This retrospective study included clinically acquired contrast-enhanced CTs of the abdomen/pelvis for children and adolescents imaged between January 2018 and July 2021. Liver and spleen volumes were derived through manual segmentation of CTs reconstructed at 2.5-, 3- or 5-mm slice thickness. A subset of images (5%, n=16) was also segmented using 0.5-mm slice thickness reconstructions to define agreement based on image slice thickness. We used Pearson correlation and multivariable regression to assess associations between organ volumes and patient characteristics. We generated reference intervals for the 5th, 25th, 50th (median), 75th and 95th percentiles for organ volumes as a function of age and weight using quantile regression models. Finally, we calculated Bland-Altman plots and intraclass correlation coefficients (ICC) to quantify agreement. Results We included a total of 320 children (mean age +/- standard deviation [SD] = 9 +/- 4.6 years; mean weight 38.1 +/- 18.8 kg; 160 female). Liver volume ranged from 340-2,002 mL, and spleen volume ranged from 28-480 mL. Patient weight (kg) (beta=12.5), age (months) (beta=1.7) and sex (female) (beta = -35.3) were independent predictors of liver volume, whereas patient weight (kg) (beta=2.4) and age (months) (beta=0.3) were independent predictors of spleen volume. There was excellent absolute agreement (ICC=0.99) and minimal absolute difference (4 mL) in organ volumes based on reconstructed slice thickness. Conclusion We report reference liver and spleen volumes for children without liver or spleen disease. These results provide reference ranges and potential thresholds to identify liver and spleen size abnormalities that might reflect disease in children.
引用
收藏
页码:378 / 386
页数:9
相关论文
共 32 条
[21]   Value-added Opportunistic CT Screening: State of the Art [J].
Pickhardt, Perry J. .
RADIOLOGY, 2022, 303 (02)
[22]  
Ringl Helmut, 2021, Radiology, V301, P348, DOI 10.1148/radiol.2021211221
[23]   Accuracy of simple approaches to assessing liver volume in radiological imaging [J].
Roloff, A. M. ;
Heiss, P. ;
Schneider, T. P. ;
Quadrat, A. ;
Kromrey, M. L. ;
Zeman, F. ;
Stroszczynski, C. ;
Mensel, B. ;
Kuehn, J. P. .
ABDOMINAL RADIOLOGY, 2016, 41 (07) :1293-1299
[24]   Comparison of automatic liver volumetry performance using different types of magnetic resonance images [J].
Saunders, Sara L. ;
Clark, Justin M. ;
Rudser, Kyle ;
Chauhan, Anil ;
Ryder, Justin R. ;
Bolan, Patrick J. .
MAGNETIC RESONANCE IMAGING, 2022, 91 :16-23
[25]   VOLUME OF THE SPLEEN IN CHILDREN AS MEASURED ON CT-SCANS - NORMAL STANDARDS AS A FUNCTION OF BODY-WEIGHT [J].
SCHLESINGER, AE ;
EDGAR, KA ;
BOXER, LA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (05) :1107-1109
[26]   SPLENIC VOLUME IN CHILDREN - SIMPLIFIED ESTIMATION AT CT [J].
SCHLESINGER, AE ;
HILDEBOLT, CF ;
SIEGEL, MJ ;
PILGRIM, TK .
RADIOLOGY, 1994, 193 (02) :578-580
[27]   Recognizing and Minimizing Arti-facts at CT, MRI, US, and Molecular Imaging [J].
Triche, Benjamin L. ;
Nelson, John T., Jr. ;
McGill, Noah S. ;
Porter, Kristin K. ;
Sanyal, Rupan ;
Tessler, Franklin N. ;
McConathy, Jonathan E. ;
Gauntt, David M. ;
Yester, Michael, V ;
Singh, Satinder P. .
RADIOGRAPHICS, 2019, 39 (04) :1017-1018
[28]   Sonographic evaluation of spleen size in apparently healthy children in north-west Ethiopia, 2020: time to define splenomegaly [J].
Tsehay, Binalfew ;
Shitie, Dessalegn ;
Afenigus, Abebe ;
Essa, Mustofa .
BMC PEDIATRICS, 2021, 21 (01)
[29]  
URATA K, 1995, HEPATOLOGY, V21, P1317, DOI 10.1016/0270-9139(95)90053-5
[30]   Standard splenic volume in children and young adults measured from CT images [J].
Watanabe, Y ;
Todani, T ;
Noda, T ;
Yamamoto, S .