Comparison of very high-power short-duration, high-power short-duration, and low-power long-duration radiofrequency ablation for atrial fibrillation: A systematic review and network meta-analysis

被引:0
作者
Junarta, Joey [1 ]
Rodriguez, Sebastian [2 ]
Ullah, Waqas [2 ]
Siddiqui, Muhammad U. [2 ]
Riley, Joshua M. [1 ]
Patel, Anjani [1 ]
O'Neill, Parker [1 ]
Dikdan, Sean J. [2 ]
Fradin, James J.
Rosen, Jake L. [3 ]
Frisch, Daniel R. [2 ,4 ]
机构
[1] Thomas Jefferson Univ Hosp, Dept Med, Philadelphia, PA USA
[2] Thomas Jefferson Univ Hosp, Jefferson Heart Inst, Philadelphia, PA USA
[3] Thomas Jefferson Univ, Sidney Kimmel Med Coll, Philadelphia, PA USA
[4] Thomas Jefferson Univ Hosp, Jefferson Heart Inst, 925 Chestnut St, Mezzanine level, Philadelphia, PA 19107 USA
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2023年 / 46卷 / 12期
关键词
PULMONARY VEIN ISOLATION; 50; W; CATHETER; OUTCOMES; SAFETY;
D O I
10.1111/pace.14879
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundThe optimal power and duration settings for radiofrequency (RF) atrial fibrillation (AF) ablation to improve efficacy and safety is unclear. We compared low-power long-duration (LPLD), high-power short-duration (HPSD), and very HPSD (vHPSD) RF settings for AF ablation.MethodsThis network meta-analysis (NMA) was structured according to the Preferred Reporting Items for Systematic Review and Meta-Analyses guidelines. Medline, Scopus and Cochrane Central Register of Controlled Trials were systematically searched to identify relevant studies. Observational and randomized studies were included. Eligible studies compared outcomes in AF patients who underwent first-time RF ablation with the following settings: vHPSD (70-90 W, 3-10 s), HPSD (45-60 W, 5-10 s), or LPLD (20-40 W, 20-60 s).ResultsThirty-six studies comprising 10,375 patients were included (33% female). Frequentist NMA showed LPLD tended toward a lower odds of freedom from arrhythmia (FFA) versus HPSD (OR 0.93, 95% CI 0.86-1.00). There was no difference in FFA between vHPSD versus HPSD. Splitwise interval estimates showed a lower odds of FFA in LPLD versus vHPSD on direct (OR 0.78, 95% CI 0.65-0.93) and network estimates (OR 0.85, 95% CI 0.73-0.98). Frequentist NMA showed less total procedural (TP) time with HPSD versus LPLD (generic variance 1.06, 95% CI 0.83 to 1.29) and no difference between HPSD versus vHPSD.ConclusionThis NMA shows improved procedural times in HPSD and vHPSD versus LPLD. Although HPSD tended toward improved odds of FFA compared to LPLD, the overall result was not statistically significant. The odds of FFA in LPLD was lower versus vHPSD on direct and network estimates on splitwise interval analysis. Large prospective head-to-head randomized trials are needed to validate HPSD and vHPSD settings.
引用
收藏
页码:1609 / 1634
页数:26
相关论文
共 63 条
  • [1] Pulmonary vein isolation using "contact force" ablation: The effect on dormant conduction and long-term freedom from recurrent atrial fibrillation-A prospective study
    Andrade, Jason G.
    Monir, George
    Pollak, Scott J.
    Khairy, Paul
    Dubuc, Marc
    Roy, Denis
    Talajic, Mario
    Deyell, Marc
    Rivard, Lena
    Thibault, Bernard
    Guerra, Peter G.
    Nattel, Stanley
    Macle, Laurent
    [J]. HEART RHYTHM, 2014, 11 (11) : 1919 - 1924
  • [2] Radiofrequency ablation annotation algorithm reduces the incidence of linear gaps and reconnection after pulmonary vein isolation
    Anter, Elad
    Tschabrunn, Cory M.
    Contreras-Valdes, Fernando M.
    Buxton, Alfred E.
    Josephson, Mark E.
    [J]. HEART RHYTHM, 2014, 11 (05) : 783 - 790
  • [3] High-Power Radiofrequency Catheter Ablation of Atrial Fibrillation Using Late Gadolinium Enhancement Magnetic Resonance Imaging as a Novel Index of Esophageal Injury
    Baher, Alex
    Kheirkhahan, Mobin
    Rechenmacher, Stephen J.
    Marashly, Qussay
    Kholmovski, Eugene G.
    Siebermair, Johannes
    Acharya, Madan
    Aljuaid, Mossab
    Morris, Alan K.
    Kaur, Gagandeep
    Han, Frederick T.
    Wilson, Brent D.
    Steinberg, Benjamin A.
    Marrouche, Nassir F.
    Chelu, Mihail G.
    [J]. JACC-CLINICAL ELECTROPHYSIOLOGY, 2018, 4 (12) : 1583 - 1594
  • [4] High-power and short-duration ablation for pulmonary vein isolation: Safety, efficacy, and long-term durability
    Barkagan, Michael
    Contreras-Valdes, Fernando M.
    Leshem, Eran
    Buxton, Alfred E.
    Nakagawa, Hiroshi
    Anter, Elad
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2018, 29 (09) : 1287 - 1296
  • [5] Pulmonary vein isolation using a higher power shorter duration CLOSE protocol with a surround flow ablation catheter
    Berte, Benjamin
    Hilfiker, Gabi
    Russi, Ian
    Moccetti, Federico
    Cuculi, Florim
    Toggweiler, Stefan
    Ruschitzka, Frank
    Kobza, Richard
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2019, 30 (11) : 2199 - 2204
  • [6] Long-term outcomes after low power, slower movement versus high power, faster movement irrigated-tip catheter ablation for atrial fibrillation
    Bunch, T. Jared
    May, Heidi T.
    Bair, Tami L.
    Crandall, Brian G.
    Cutler, Michael J.
    Mallender, Charles
    Weiss, J. Peter
    Osborn, Jeffrey S.
    Day, John D.
    [J]. HEART RHYTHM, 2020, 17 (02) : 184 - 189
  • [7] Calkins H, 2017, HEART RHYTHM, V14, pE445, DOI [10.1016/j.hrthm.2017.05.012, 10.1016/j.hrthm.2017.07.009, 10.1093/europace/eux275]
  • [8] Feasibility and safety of pulmonary vein isolation by high-power short-duration radiofrequency application: short-term results of the POWER-FAST PILOT study
    Castrejon-Castrejon, Sergio
    Martinez Cossiani, Marcel
    Ortega Molina, Marta
    Escobar, Carlos
    Froilan Torres, Consuelo
    Gonzalo Bada, Nerea
    Diaz de la Torre, Marta
    Suarez Parga, Jose Manuel
    Lopez Sendon, Jose Luis
    Luis Merino, Jose
    [J]. JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2020, 57 (01) : 57 - 65
  • [9] Comparison of high-power short-duration and low-power long-duration radiofrequency ablation for treating atrial fibrillation: Systematic review and meta-analysis
    Chen, Chao-feng
    Wu, Jing
    Jin, Chao-lun
    Liu, Mei-jun
    Xu, Yi-zhou
    [J]. CLINICAL CARDIOLOGY, 2020, 43 (12) : 1631 - 1640
  • [10] Comparison of lesion characteristics between conventional and high-power short-duration ablation using contact force-sensing catheter in patients with paroxysmal atrial fibrillation
    Chen, Chun-Chao
    Lee, Po-Tseng
    Vu Van Ba
    Chuang, Chieh-Mao
    Lin, Yenn-Jiang
    Lo, Li-Wei
    Hu, Yu-Feng
    Chung, Fa-Po
    Lin, Chin-Yu
    Chang, Ting-Yung
    Vicera, Jennifer Jeanne
    Huang, Ting-Chun
    Liu, Chih-Min
    Wu, Cheng-, I
    Lugtu, Isaiah C.
    Jain, Ankit
    Chang, Shih-Lin
    Chen, Shih-Ann
    [J]. BMC CARDIOVASCULAR DISORDERS, 2021, 21 (01)