The apparent effusivity method for normalized thermal contrast evaluation in infrared thermographic testing

被引:3
|
作者
Moskovchenko, Alexey [1 ]
Svantner, Michal [1 ]
Muzika, Lukas [1 ]
Skala, Jiri [1 ]
Pereira, Celeste M. C. [2 ]
Das, Shumit [3 ]
机构
[1] Univ West Bohemia, Univ 2732-8, Plzen 30100, Czech Republic
[2] Optimal Struct Solut Lda, Rua Moinho Vermelho 50, P-2645449 Cascais, Portugal
[3] European Space Res Technol Ctr ESA ESTEC, Keplerlaan 1, NL-2200 AG Noordwijk, Netherlands
关键词
Infrared thermography; Nondestructive testing; Contrast; CNR; CFRP; Defects quantification; Nondestructive evaluation; Nondestructive inspection; IRNDT; Thermographic testing; Defects contrast; DEFECT CHARACTERIZATION; NDT; TOMOGRAPHY;
D O I
10.1016/j.infrared.2023.104931
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Thermographic nondestructive testing is used for the detection of near-surface discontinuities in materials, where indications of potential defects or discontinuities are detected and evaluated by their thermal contrast. The key requirements for successful thermographic data processing include managing non-uniform heating and identifying nominal areas. Advanced methods often rely on numerical simulation, which can be challenging and timeconsuming. This study suggests a new simple method of thermal contrast calculation for flash-pulse thermography. It is based on the analysis of the inverse apparent effusivity. It includes an automated indication of the sound (defect-free) area and the creation of an artificial reference sequence, which is based on a temperature profile of the sound area and the non-uniform heating map. Derivative analysis of the smoothed contrast data is applied to improve detectability and Contrast/Noise Ratio (CNR). An experimental comparison of the proposed method with other known methods is presented. In the presented example, it allowed detection of 23 defects with an average CNR of 6.13 dB, against the traditional differential absolute contrast method, which detected only 13 defects with an average CNR of 0.53 dB. Thus, high detectability and high CNR values provided by the proposed method are demonstrated.
引用
收藏
页数:12
相关论文
共 13 条
  • [1] Active IR Thermography Evaluation of Coating Thickness by Determining Apparent Thermal Effusivity
    Moskovchenko, Alexey
    Vavilov, Vladimir
    Svantner, Michal
    Muzika, Lukas
    Houdkova, Sarka
    MATERIALS, 2020, 13 (18)
  • [2] A new thermal contrast for non-destructive thermographic testing of materials
    Benitez, Heinan D.
    Ibarra-Castanedo, Clemente
    Bendada, Abdelhakim
    Maldague, Xavier
    Loaiza, Humberto
    Caicedo, Eduardo
    INGENIERIA Y COMPETITIVIDAD, 2007, 9 (01): : 31 - 44
  • [3] Infrared thermographic nondestructive testing of frescos:: Thermal modeling and image processing of three dimensional heat diffusion phenomena
    Vavilov, V
    Marinetti, S
    Grinzato, E
    Bison, PG
    Dal Toè, S
    Burleigh, D
    MATERIALS EVALUATION, 2002, 60 (03) : 452 - 460
  • [4] Infrared thermographic evaluation of thermal release phenomena in polycarbonate during plastic deformation
    Chen, Lu
    Zhang, Mingyuan
    Li, Dejian
    Li, Yingjun
    ADVANCED INDUSTRIAL AND ENGINEERING POLYMER RESEARCH, 2023, 6 (01) : 39 - 48
  • [5] Modified differential absolute contrast using thermal quadrupoles for the nondestructive testing of finite thickness specimens by infrared thermography
    Benitez, Hernan
    Ibarra-Castanedo, Clemente
    Bendada, Abdelhakim.
    Maldague, Xavier
    Loaiza, Humberto
    Caicedo, Eduardo
    2006 Canadian Conference on Electrical and Computer Engineering, Vols 1-5, 2006, : 818 - 821
  • [6] Coded thermal wave imaging technique for infrared non-destructive testing and evaluation
    Mulaveesala, Ravibabu
    Arora, Vanita
    Rani, Anju
    NONDESTRUCTIVE TESTING AND EVALUATION, 2019, 34 (03) : 243 - 253
  • [7] Nondestructive Testing Evaluation of Aircraft Fuselage Corrosion by Infrared Thermography and Finite Element Method
    Eddazi, Abderrahman
    Belattar, Sougrati
    2017 14TH INTERNATIONAL CONFERENCE ON COMPUTER GRAPHICS, IMAGING AND VISUALIZATION (CGIV 2017), 2017, : 56 - 61
  • [8] Nondestructive Testing Method of Post Porcelain Insulator Based on Pulsed Infrared Thermal Wave Technology
    Wang L.
    Liu L.
    Mei H.
    Guo C.
    Zhao C.
    Feng L.
    1600, Chinese Society for Electrical Engineering (37): : 7359 - 7366
  • [9] Infrared Thermal Imaging for Evaluation of Clubfoot After the Ponseti Casting Method-An Exploratory Study
    Ganesan, Balasankar
    Yip, Joanne
    Luximon, Ameersing
    Gibbons, Paul J.
    Chivers, Alison
    Balasankar, Suchita Kothe
    Tong, Raymond Kai-Yu
    Chai, Rifai
    Al-Jumaily, Adel
    FRONTIERS IN PEDIATRICS, 2021, 9
  • [10] Nondestructive Testing and Evaluation Method of Thermal Aging of CF-8M Cast Stainless Steel
    Xiao Q.
    Zhao C.
    Wang Y.
    Chen Y.
    Xu Z.
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2022, 56 (10): : 2232 - 2238