Marginal gap and internal fit of 3D printed versus milled monolithic zirconia crowns

被引:27
作者
Refaie, Ashraf [1 ,2 ,3 ]
Fouda, Ahmed [1 ]
Bourauel, Christoph [1 ]
Singer, Lamia [1 ,4 ]
机构
[1] Univ Hosp Bonn, Oral Med Technol, Bonn, Germany
[2] Fayoum Univ, Fac Dent, Dept Fixed Prosthodont, Faiyum, Egypt
[3] British Univ Egypt, Fac Oral & Dent Med, Cairo, Egypt
[4] Univ Hosp Bonn, Dept Orthodont, Bonn, Germany
关键词
Yttria-stabilized zirconia crowns; 3D printing; Subtractive manufacturing; Marginal gap; Internal fit; CAD-CAM; ADAPTATION; DISCREPANCIES; ACCURACY; COPINGS;
D O I
10.1186/s12903-023-03184-8
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
BackgroundThis study aimed to evaluate and compare the marginal gap using two different methods and the internal fit of 3D printed and zirconia crowns.Methods3Y-TZP zirconia crowns (n = 20) were manufactured using subtractive milling (group M) and 3D printed (group P). The marginal gap was measured at 60 points using vertical marginal gap technique (VMGT). On the other hand, the silicone replica technique (SRT) was used to evaluate the internal fit and was divided into 4 groups: marginal gap, cervical gap, axial gap, and occlusal gap where the thickness of light impression was measured at 16 references. The numerical data was tested for normality using Shapiro-Wilk's test. They were found to be normally distributed and were analyzed using an independent t-test.ResultsUsing VMGT, group P had significantly higher mean marginal gap values of 80 & PLUSMN; 30 & mu;m compared to group M = 60 & PLUSMN; 20 & mu;m (p < 0.001). Also, with the SRT, the marginal gap of group P (100 & PLUSMN; 10 & mu;m) had significantly higher values compared to group M (60 & PLUSMN; 10 & mu;m). The internal fit showed significant difference between the tested groups except for Axial Gap.ConclusionsAlthough milled crowns showed better results. The 3D printed zirconia crowns offer clinically acceptable results in terms of marginal adaptation and internal fit. Both VMGT and SRT are reliable methods for the assessment of the marginal gap.
引用
收藏
页数:7
相关论文
共 50 条
[1]   Marginal gap and internal fit of 3D printed versus milled monolithic zirconia crowns [J].
Ashraf Refaie ;
Ahmed Fouda ;
Christoph Bourauel ;
Lamia Singer .
BMC Oral Health, 23
[2]   Marginal fit of monolithic versus layered zirconia crowns assessed with 2 marginal gap methods [J].
Fasih, Paniz ;
Tavakolizadeh, Sara ;
Monfared, Majid Sedaghat ;
Sofi-Mahmudi, Ahmad ;
Yari, Amir .
JOURNAL OF PROSTHETIC DENTISTRY, 2023, 130 (02) :250.e1-250.e7
[3]   Effect of aging on the marginal fit of milled and printed zirconia crowns: an in-vitro study [J].
Elsayed, Mahmoud S. ;
El-Kouedi, Ahmed Y. ;
Shokry, Tamer E. .
BMC ORAL HEALTH, 2025, 25 (01)
[4]   Trueness and precision of 3D-printed versus milled monolithic zirconia crowns: An in vitro study [J].
Lerner, Henriette ;
Nagy, Katalin ;
Pranno, Nicola ;
Zarone, Fernando ;
Admakin, Oleg ;
Mangano, Francesco .
JOURNAL OF DENTISTRY, 2021, 113
[5]   Fit, Precision, and Trueness of 3D-Printed Zirconia Crowns Compared to Milled Counterparts [J].
Abualsaud, Reem ;
Alalawi, Haidar .
DENTISTRY JOURNAL, 2022, 10 (11)
[6]   Marginal and internal fit of provisional crowns fabricated using 3D printing technology [J].
Chaturvedi, Saurabh ;
Alqahtani, Nasser M. ;
Addas, Mohamed Khaled ;
Alfarsi, Mohammed A. .
TECHNOLOGY AND HEALTH CARE, 2020, 28 (06) :635-642
[7]   Marginal and internal fit of 3D printed provisional crowns according to build directions [J].
Ryu, Ji-Eun ;
Kim, Yu-Lee ;
Kong, Hyun-Jun ;
Chang, Hoon-Sang ;
Jung, Ji-Hye .
JOURNAL OF ADVANCED PROSTHODONTICS, 2020, 12 (04) :225-232
[8]   Marginal Discrepancy and Internal Fit of 3D-Printed Versus Milled Laminate Veneers: An In Vitro Study [J].
Daghrery, Arwa ;
Lunkad, Honey ;
Mobarki, Khalid ;
Alhazmi, Majed ;
Khubrani, Hussain ;
Vinothkumar, Thilla Sekar ;
Jabarti, Eman .
JOURNAL OF FUNCTIONAL BIOMATERIALS, 2024, 15 (11)
[9]   Marginal and Internal Fit of Monolithic Zirconia Crowns Fabricated by Using Two Different CAD-CAM Workflows: An In Vitro Study [J].
Cin, Vahap ;
Izgi, Ayca Deniz ;
Kale, Ediz ;
Yilmaz, Burak .
PROSTHESIS, 2023, 5 (01) :35-47
[10]   Marginal fit of full contour monolithic zirconia in different thicknesses and layered zirconia crowns [J].
Mohaghegh, Mina ;
Firouzmandi, Maryam ;
Ansarifard, Elham ;
Ramazani, Laleh .
JOURNAL OF INTERNATIONAL SOCIETY OF PREVENTIVE AND COMMUNITY DENTISTRY, 2020, 10 (05) :652-658