A generalizable deep learning regression model for automated glaucoma screening from fundus images

被引:25
|
作者
Hemelings, Ruben [1 ,2 ]
Elen, Bart [2 ]
Schuster, Alexander K. [3 ]
Blaschko, Matthew B. [4 ]
Barbosa-Breda, Joao [1 ,5 ,6 ]
Hujanen, Pekko [7 ]
Junglas, Annika [3 ]
Nickels, Stefan [3 ]
White, Andrew [8 ]
Pfeiffer, Norbert [3 ]
Mitchell, Paul [8 ]
De Boever, Patrick [9 ,10 ]
Tuulonen, Anja [7 ]
Stalmans, Ingeborg [1 ,11 ]
机构
[1] Katholieke Univ Leuven, Dept Neurosci, Res Grp Ophthalmol, Herestr 49, B-3000 Leuven, Belgium
[2] Flemish Inst Technol Res VITO, Boeretang 200, B-2400 Mol, Belgium
[3] Univ Med Ctr Mainz, Dept Ophthalmol, Langenbeckstr 1, D-55131 Mainz, Germany
[4] Katholieke Univ Leuven, ESAT PSI, Kasteelpk Arenberg 10, B-3001 Leuven, Belgium
[5] Univ Porto, Fac Med, Cardiovasc R&D Ctr, Alameda Prof Hernani Monteiro, P-4200319 Porto, Portugal
[6] Univ Sao Joao, Ctr Hosp, Dept Ophthalmol, Alameda Prof Hernani Monteiro, P-4200319 Porto, Portugal
[7] Tampere Univ Hosp, Tays Eye Ctr, Tampere, Finland
[8] Univ Sydney, Dept Ophthalmol, Sydney, NSW, Australia
[9] Hasselt Univ, Ctr Environm Sci, Agoralaan Bldg, B-3590 Diepenbeek, Belgium
[10] Univ Antwerp, Dept Biol, B-2610 Antwerp, Belgium
[11] UZ Leuven, Ophthalmol Dept, Herestr 49, B-3000 Leuven, Belgium
关键词
OPEN-ANGLE GLAUCOMA; OCULAR HYPERTENSION TREATMENT; FIBER LAYER DEFECTS; OPTIC DISC; PREVALENCE; POPULATION; SEGMENTATION; ALGORITHM; ACCURACY; DATABASE;
D O I
10.1038/s41746-023-00857-0
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
A plethora of classification models for the detection of glaucoma from fundus images have been proposed in recent years. Often trained with data from a single glaucoma clinic, they report impressive performance on internal test sets, but tend to struggle in generalizing to external sets. This performance drop can be attributed to data shifts in glaucoma prevalence, fundus camera, and the definition of glaucoma ground truth. In this study, we confirm that a previously described regression network for glaucoma referral (G-RISK) obtains excellent results in a variety of challenging settings. Thirteen different data sources of labeled fundus images were utilized. The data sources include two large population cohorts (Australian Blue Mountains Eye Study, BMES and German Gutenberg Health Study, GHS) and 11 publicly available datasets (AIROGS, ORIGA, REFUGE1, LAG, ODIR, REFUGE2, GAMMA, RIM-ONEr3, RIM-ONE DL, ACRIMA, PAPILA). To minimize data shifts in input data, a standardized image processing strategy was developed to obtain 30 degrees disc-centered images from the original data. A total of 149,455 images were included for model testing. Area under the receiver operating characteristic curve (AUC) for BMES and GHS population cohorts were at 0.976 [95% CI: 0.967-0.986] and 0.984 [95% CI: 0.980-0.991] on participant level, respectively. At a fixed specificity of 95%, sensitivities were at 87.3% and 90.3%, respectively, surpassing the minimum criteria of 85% sensitivity recommended by Prevent Blindness America. AUC values on the eleven publicly available data sets ranged from 0.854 to 0.988. These results confirm the excellent generalizability of a glaucoma risk regression model trained with homogeneous data from a single tertiary referral center. Further validation using prospective cohort studies is warranted.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] A generalizable deep learning regression model for automated glaucoma screening from fundus images
    Ruben Hemelings
    Bart Elen
    Alexander K. Schuster
    Matthew B. Blaschko
    João Barbosa-Breda
    Pekko Hujanen
    Annika Junglas
    Stefan Nickels
    Andrew White
    Norbert Pfeiffer
    Paul Mitchell
    Patrick De Boever
    Anja Tuulonen
    Ingeborg Stalmans
    npj Digital Medicine, 6
  • [2] Screening for Glaucoma from Fundus Images via Multitask Deep Learning
    Li, Shuo
    Sui, Xiaodan
    Wang, Yu
    Che, Tongtong
    Jiao, Wanzhen
    Zhao, Bojun
    Zheng, Yuanjie
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (07)
  • [3] Automated Glaucoma Screening from Retinal Fundus Image Using Deep Learning
    Phasuk, S.
    Poopresert, P.
    Yaemsuk, A.
    Suvannachart, P.
    Itthipanichpong, R.
    Chansangpetch, S.
    Manassakorn, A.
    Tantisevi, V
    Rojanapongpun, P.
    Tantibundhit, C.
    2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2019, : 904 - 907
  • [4] Automated glaucoma screening in retinal fundus images
    Aruchamy, Srinivasan
    Bhattacharjee, Partha
    Sanyal, Goutam
    International Journal of Multimedia and Ubiquitous Engineering, 2015, 10 (09): : 129 - 136
  • [5] An Automated Deep Learning Approach to Diagnose Glaucoma using Retinal Fundus Images
    Shoukat, Ayesha
    Akbar, Shahzad
    Hassan, Syed Al E.
    Rehman, Amjad
    Ayesha, Noor
    2021 INTERNATIONAL CONFERENCE ON FRONTIERS OF INFORMATION TECHNOLOGY (FIT 2021), 2021, : 120 - 125
  • [6] Automated Glaucoma Screening and Diagnosis Based on Retinal Fundus Images Using Deep Learning Approaches: A Comprehensive Review
    Zedan, Mohammad J. M.
    Zulkifley, Mohd Asyraf
    Ibrahim, Ahmad Asrul
    Moubark, Asraf Mohamed
    Kamari, Nor Azwan Mohamed
    Abdani, Siti Raihanah
    DIAGNOSTICS, 2023, 13 (13)
  • [7] ODGNet: a deep learning model for automated optic disc localization and glaucoma classification using fundus images
    Latif, Jahanzaib
    Tu, Shanshan
    Xiao, Chuangbai
    Rehman, Sadaqat Ur
    Imran, Azhar
    Latif, Yousaf
    SN APPLIED SCIENCES, 2022, 4 (04):
  • [8] ODGNet: a deep learning model for automated optic disc localization and glaucoma classification using fundus images
    Jahanzaib Latif
    Shanshan Tu
    Chuangbai Xiao
    Sadaqat Ur Rehman
    Azhar Imran
    Yousaf Latif
    SN Applied Sciences, 2022, 4
  • [9] Identification of glaucoma from fundus images using deep learning techniques
    Ajitha, S.
    Akkara, John D.
    Judy, M., V
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2021, 69 (10) : 2702 - 2709
  • [10] Deep Ensemble Learning for Classification of Glaucoma from Smartphone Fundus Images
    Angara, Sandeep
    Kim, Jongwoo
    2024 IEEE 37TH INTERNATIONAL SYMPOSIUM ON COMPUTER-BASED MEDICAL SYSTEMS, CBMS 2024, 2024, : 412 - 417