Three-Dimensional Freehand Ultrasound Strain Elastography Based on the Assessment of Endogenous Motion: Phantom Study

被引:1
|
作者
Sakalauskas, Andrius [1 ]
Jurkonis, Rytis [2 ]
Lukosevicius, Arunas [2 ]
机构
[1] TELEMED, Ultrasound Med Syst, Vilnius, Lithuania
[2] Kaunas Univ Technol, Biomed Engn Inst, Kaunas, Lithuania
关键词
strain elastography; endogenous motion; freehand scanning; 3D imaging; tissue mimicking phan; WFUMB GUIDELINES; CLINICAL-USE; RECOMMENDATIONS;
D O I
10.24425/aoa.2023.144269
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The purpose of this paper is to present the results of the pilot experiments demonstrating proof of concept of three-dimensional strain elastography, based on freehand ultrasound for the assessment of strain induced by endogenous motion. The technique was tested by inducing pulsatility in an agar-based tissue mimicking phantom with inclusions having different stiffness and scanning the 1D array with an electromagnetic position sensor. The proof of concept is explored with a defined physical phantom and the adopted algorithm for strain analysis. The agar-based phantom was manufactured with two cylindrical inclusions having different stiffness (7 kPa and 75 kPa in comparison to the background 25 kPa) and scattering properties. The internal strain in the phantom was introduced by mimicking a pulsating artery. The agar mixture displacements were estimated by using the GLUE algorithm. The 3D isosurfaces of inclusion from rendered volumes obtained from the B-mode image set and strain elastograms were reconstructed and superimposed for a quantitative comparison. The correspondence between the B-mode image-based inclusion volume and the strain elastography-based volume was good (the Jaccard similarity coefficient in the range 0.64-0.74). The obtained results confirm the 3D freehand endogenous motion-based elastography as a feasible technique. The visualization of the inclusions was successful. However, quantitative measurements showed that the accuracy of the method in volumetric measurements is limited.
引用
收藏
页码:219 / 229
页数:11
相关论文
共 50 条
  • [41] Freehand three-dimensional assessment of left ventricular volumes and ejection fraction with ultrasound contrast agent LK565
    Geisler, T.
    Rost, H. C.
    Wild, P. S.
    Zotz, R.
    EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2007, 8 (01): : 19 - 29
  • [42] Assessment of left ventricular strain by three-dimensional wall-motion tracking technology: a study in hypertrophic cardiomyopathy
    Marques, L.
    Moreno, N.
    Guedes, H.
    Santos, R.
    Pereira, A.
    Seabra, D.
    Sousa, R.
    Pinto, P.
    EUROPEAN JOURNAL OF HEART FAILURE, 2017, 19 : 564 - 565
  • [43] The reliability and validity of triceps surae muscle volume assessment using freehand three-dimensional ultrasound in typically developing infants
    Williams, Sian A.
    Bell, Matthew
    Kim, Hyun K.
    Al Masruri, Ghaliya Salim
    Stott, N. Susan
    Fernandez, Justin
    Mirjalili, S. Ali
    JOURNAL OF ANATOMY, 2022, 240 (03) : 567 - 578
  • [44] Three-dimensional shear wave elastography on conventional ultrasound scanners with external vibration
    Huang, Chengwu
    Song, Pengfei
    Mellema, Daniel C.
    Gong, Ping
    Lok, U-Wai
    Tang, Shanshan
    Ling, Wenwu
    Meixner, Duane D.
    Urban, Matthew W.
    Manduca, Armando
    Greenleaf, James F.
    Chen, Shigao
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (21):
  • [45] Neural Network-based Motion Tracking for Breast Ultrasound Strain Elastography: An Initial Assessment of Performance and Feasibility
    Peng, Bo
    Xian, Yuhong
    Zhang, Quan
    Jiang, Jingfeng
    ULTRASONIC IMAGING, 2020, 42 (02) : 74 - 91
  • [46] Cumulus assessment by three-dimensional ultrasound for in vitro fertilization
    Poehl, M
    Hohlagschwandtner, M
    Doerner, V
    Dillinger, B
    Feichtinger, W
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2000, 16 (03) : 251 - 253
  • [47] A Mobile Force Plate and Three-Dimensional Motion Analysis System for Three-Dimensional Gait Assessment
    Liu, Tao
    Inoue, Yoshio
    Shibata, Kyoko
    Shiojima, K.
    IEEE SENSORS JOURNAL, 2012, 12 (05) : 1461 - 1467
  • [48] Fetal heart volume assessment by three-dimensional ultrasound
    Chang, FM
    Hsu, KF
    Ko, HC
    Yao, BL
    Chang, CH
    Yu, CH
    Liang, TI
    Chen, HY
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 1997, 9 (01) : 42 - 48
  • [49] Three-dimensional ultrasound assessment of endometrial receptivity:: a review
    Alcazar, Juan Luis
    REPRODUCTIVE BIOLOGY AND ENDOCRINOLOGY, 2006, 4 (1)
  • [50] Three-dimensional ultrasound assessment of endometrial receptivity: a review
    Juan Luis Alcázar
    Reproductive Biology and Endocrinology, 4