Pt/MXene-Based Flexible Wearable Non-Enzymatic Electrochemical Sensor for Continuous Glucose Detection in Sweat

被引:133
作者
Li, Quan-Fu [1 ]
Chen, Xu [1 ]
Wang, Hai [2 ]
Liu, Ming [2 ]
Peng, Hui-Ling [1 ]
机构
[1] Guangxi Normal Univ, Sch Elect & Informat Engn, Sch Integrated Circuits, Guangxi Key Lab Integrated Circuits & Microsyst, Guilin 541004, Peoples R China
[2] Guangxi Normal Univ, Coll Phys & Technol, Guangxi Key Lab Nucl Phys & Technol, Guilin 541004, Peoples R China
基金
中国国家自然科学基金;
关键词
wearable sensor; non-enzymatic electrochemical sensor; sweat glucose; Pt; MXene; FILM;
D O I
10.1021/acsami.2c20543
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Wearable non-invasive sensors facilitate the con-tinuous measurement of glucose in sweat for the treatment and management of diabetes. However, the catalysis of glucose and sweat sampling are challenges in the development of efficient wearable glucose sensors. Herein, we report a flexible wearable non-enzymatic electrochemical sensor for continuous glucose detection in sweat. We synthesized a catalyst (Pt/MXene) by the hybridization of Pt nanoparticles onto MXene (Ti3C2Tx) nanosheets with a broad linear range of glucose detection (0-8 mmol/L) under neutral conditions. Furthermore, we optimized the structure of the sensor by immobilizing Pt/MXene with a conductive hydrogel to enhance the stability of the sensor. Based on Pt/MXene and the optimized structure, we fabricated a flexible wearable glucose sensor by integrating a microfluidic patch for sweat collection onto a flexible sensor. We evaluated the utility of the sensor for the detection of glucose in sweat, and the sensor could detect the glucose change with the replenishment and consumption of energy by the body, and a similar trend was observed in the blood. An in vivo glucose test in sweat indicated that the fabricated sensor is promising for the continuous measurement of glucose, which is essential for the treatment and management of diabetes.
引用
收藏
页码:13290 / 13298
页数:9
相关论文
共 38 条
[1]   A stretchable and screen-printed electrochemical sensor for glucose determination in human perspiration [J].
Abellan-Llobregat, A. ;
Jeerapan, Itthipon ;
Bandodkar, A. ;
Vidal, L. ;
Canals, A. ;
Wang, J. ;
Morallon, E. .
BIOSENSORS & BIOELECTRONICS, 2017, 91 :885-891
[2]   Superhydrophobic Functionalized Ti3C2Tx MXene-Based Skin-Attachable and Wearable Electrochemical pH Sensor for Real-Time Sweat Detection [J].
Chen, Lijuan ;
Chen, Fan ;
Liu, Gang ;
Lin, Haoliang ;
Bao, Yu ;
Han, Dongxue ;
Wang, Wei ;
Ma, Yingming ;
Zhang, Baohua ;
Niu, Li .
ANALYTICAL CHEMISTRY, 2022, 94 (20) :7319-7328
[3]   A double-layered liquid metal-based electrochemical sensing system on fabric as a wearable detector for glucose in sweat [J].
Chen, Xuanqi ;
Wan, Hao ;
Guo, Rui ;
Wang, Xinpeng ;
Wang, Yang ;
Jiao, Caicai ;
Sun, Kang ;
Hu, Liang .
MICROSYSTEMS & NANOENGINEERING, 2022, 8 (01)
[4]   IDF Diabetes Atlas: Global estimates of diabetes prevalence for 2017 and projections for 2045 [J].
Cho, N. H. ;
Shaw, J. E. ;
Karuranga, S. ;
Huang, Y. ;
Fernandes, J. D. da Rocha ;
Ohlrogge, A. W. ;
Malanda, B. .
DIABETES RESEARCH AND CLINICAL PRACTICE, 2018, 138 :271-281
[5]   Skin-interfaced systems for sweat collection and analytics [J].
Choi, Jungil ;
Ghaffari, Roozbeh ;
Baker, Lindsay B. ;
Rogers, John A. .
SCIENCE ADVANCES, 2018, 4 (02)
[6]   Chronopotentiometric study of a Nafion membrane in presence of glucose [J].
Freijanes, Y. ;
Barragan, V. M. ;
Munoz, S. .
JOURNAL OF MEMBRANE SCIENCE, 2016, 510 :79-90
[7]   Conductive two-dimensional titanium carbide 'clay' with high volumetric capacitance [J].
Ghidiu, Michael ;
Lukatskaya, Maria R. ;
Zhao, Meng-Qiang ;
Gogotsi, Yury ;
Barsoum, Michel W. .
NATURE, 2014, 516 (7529) :78-U171
[8]   Pt-poly(L-lactic acid) microelectrode-based microsensor for in situ glucose detection in sweat [J].
Han, JingYi ;
Li, Mingji ;
Li, Hongji ;
Li, Cuiping ;
Ye, Jianshan ;
Yang, Baohe .
BIOSENSORS & BIOELECTRONICS, 2020, 170 (170)
[9]   Two-dimensional transition metal carbides and nitrides (MXenes) for biomedical applications [J].
Huang, Kai ;
Li, Zhongjun ;
Lin, Jing ;
Han, Gang ;
Huang, Peng .
CHEMICAL SOCIETY REVIEWS, 2018, 47 (14) :5109-5124
[10]   Facet-Dependent Cu2O Electrocatalysis for Wearable Enzyme-Free Smart Sensing [J].
Jiang, Yu ;
Xia, Tong ;
Shen, Liuxue ;
Ma, Junlin ;
Ma, Hongting ;
Sun, Tongrui ;
Lv, Fengjuan ;
Zhu, Nan .
ACS CATALYSIS, 2021, 11 (05) :2949-2955