Explicit Non-linear Finite Element Analysis for Prediction of Primary Stability in Uncemented Total Hip Arthroplasty

被引:2
|
作者
Ovesy, Marzieh [1 ]
Zysset, Philippe K. [1 ]
机构
[1] Univ Bern, ARTORG Ctr Biomed Engn Res, Freiburgstr 3, CH-3010 Bern, Switzerland
来源
COMPUTER METHODS, IMAGING AND VISUALIZATION IN BIOMECHANICS AND BIOMEDICAL ENGINEERING II | 2023年 / 38卷
关键词
Explicit finite element; Press-Fit; Implantation; Micromotions; FEMORAL COMPONENT; MESHLESS METHODS; CANCELLOUS BONE; EARLY MIGRATION; STEM; MICROMOTION; REPLACEMENT; INTERFACE; FRACTURE; IMPLANT;
D O I
10.1007/978-3-031-10015-4_12
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Primary stability in uncemented total hip arthroplasty is often assessed by insertion force, relative micromotions at the interface or subsidence of the femoral stem. This study aimed to simulate implantation process and evaluate the press-fit effect imposed at this stage on the primary stability outcome. The femur was modeled as an elasto-plastic material with element deletion based on cumulation of plastic strain represented as damage. The implantation phasewas simulated using a displacement constraint that led to implant self-positioning by frictional contact. A subsequent force-controlled, loading-unloading cycle corresponding to the peak of a gait cycle was applied. Implantation force and work, implant subsidence and relative micromotions during the loading cycle were quantified. The modeling strategy was performed on two levels of hypothetical initial press-fit to capture the extreme influence of press-fit on the subsequent outcomes. The implantation force was 21.5% higher for the high press-fit approach. The implant remained more stable during the loading cycle for low press-fit model based on subsidence values. Micromotions showed also a significant dependency on press-fit. The median values of micromotions were below 150 mu m for both press-fit models, which is in good agreement with the literature. This study demonstrates feasibility of simulating the implantation stage and investigating the effect of press-fit on primary stability of an individual total hip arthroplasty planning.
引用
收藏
页码:128 / 142
页数:15
相关论文
共 50 条
  • [1] Initial Stability of Subtrochanteric Oblique Osteotomy in Uncemented Total Hip Arthroplasty: A Preliminary Finite Element Study
    Li, Liangtao
    Yu, Mingyang
    Ma, Renshi
    Zhu, Dong
    Gu, Guishan
    MEDICAL SCIENCE MONITOR, 2015, 21 : 1969 - 1975
  • [2] The influence of contact ratio and its location on the primary stability of cementless total hip arthroplasty: A finite element analysis
    Reimeringer, M.
    Nuno, N.
    JOURNAL OF BIOMECHANICS, 2016, 49 (07) : 1064 - 1070
  • [3] The assessment of implant shape-dependent failure mechanisms in primary total hip arthroplasty using finite element analysis
    Kazemirad, Siavash
    Yazdi, Mohammad Ali
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2025, 28 (06) : 750 - 763
  • [4] Finite Element Analysis of Proximal Cement Fixation in Total Hip Arthroplasty
    Ahmad, Maizatul Afirah
    Zulkifli, Nurul Nadhirah Mohamed Elias
    Shuib, Solehuddin
    Sulaiman, Shahrul Hisham
    Abdullah, Abdul Halim
    INTERNATIONAL JOURNAL OF TECHNOLOGY, 2020, 11 (05) : 1046 - 1055
  • [5] Revision total hip arthroplasty with an uncemented primary stem in 79 patients
    Thorey, Fritz
    Lerch, Matthias
    Kiel, Heike
    von Lewinski, Gabriela
    Stukenborg-Colsman, Christina
    Windhagen, Henning
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2008, 128 (07) : 673 - 678
  • [6] Revision total hip arthroplasty with an uncemented primary stem in 79 patients
    Fritz Thorey
    Matthias Lerch
    Heike Kiel
    Gabriela von Lewinski
    Christina Stukenborg-Colsman
    Henning Windhagen
    Archives of Orthopaedic and Trauma Surgery, 2008, 128 : 673 - 678
  • [7] Does a Collar Improve the Immediate Stability of Uncemented Femoral Hip Stems in Total Hip Arthroplasty? A Bilateral Comparative Cadaver Study
    Demey, Guillaume
    Fary, Camdon
    Lustig, Sebastien
    Neyret, Philippe
    Selmi, Tank Ait Si
    JOURNAL OF ARTHROPLASTY, 2011, 26 (08) : 1549 - 1555
  • [8] Descriptive Analysis of Internal Registry Data on Cemented and Uncemented Total Hip Arthroplasty
    Avram, George M.
    Stefan, Anca
    Paraschiv, Radu
    Dugaesescu, Monica
    Tillieci-Minnetti, Leonardo
    ROMANIAN JOURNAL OF MILITARY MEDICINE, 2023, 126 (04) : 467 - 473
  • [9] Biomechanical effect of metal augment and bone graft on cup stability for acetabular reconstruction of total hip arthroplasty in hip dysplasia: a finite element analysis
    Wang, Yuzhu
    Wang, Mincong
    Li, Chengguo
    Nakamura, Yoshihiro
    Deng, Liwei
    Yamako, Go
    Chosa, Etsuo
    Pan, Chenglong
    BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)
  • [10] Comparative Survival of Uncemented Acetabular Components Following Primary Total Hip Arthroplasty
    Howard, James L.
    Kremers, Hilal Maradit
    Loechler, Youlonda A.
    Schleck, Cathy D.
    Harmsen, William S.
    Berry, Daniel J.
    Cabanela, Miguel E.
    Hanssen, Arlen D.
    Pagnano, Mark W.
    Trousdale, Robert T.
    Lewallen, David G.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2011, 93A (17) : 1597 - 1604