An ATMND/SGI based three-way junction ratiometric fluorescent probe for rapid and sensitive detection of bleomycin

被引:1
作者
Kong, Rong-Mei [1 ]
Han, Xue [1 ]
Li, Peihua [1 ]
Zhao, Yan [1 ]
Kong, Weiheng [1 ]
Xiang, Mei-Hao [1 ]
Xia, Lian [1 ]
Qu, Fengli [1 ]
机构
[1] Qufu Normal Univ, Sch Chem & Chem Engn, Key Lab Life Organ Anal Shandong Prov, Qufu 273165, Shandong, Peoples R China
关键词
LABEL-FREE; COCAINE; IDENTIFICATION; APTASENSOR; STRATEGY; ATP;
D O I
10.1039/d3an02186f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, we developed a rapid and sensitive label-free ratiometric fluorescent (FL) probe for the detection of bleomycin (BLM). The probe consists of a DNA sequence (D6) and two fluorophore groups, 2-amino-5,6,7-trimethyl-1,8-naphthalene (ATMND) and SYBR Green I (SGI). The D6 sequence could be folded into a three-way junction structure containing a C-C mismatch position in the junction pocket. The unique "Y" structure not only could entrap ATMND in the mismatch pocket with high affinity, leading to FL quenching at 408 nm, but also embed SGI in the grooves of the double-stranded portion, resulting in FL enhancement at 530 nm. In the presence of BLM-Fe(ii), the "Y" structure of D6 was destroyed due to the specific cleavage of the BLM recognition site, the 5 '-GT-3 ' site in D6. This caused the release of ATMND and SGI and thus the ratiometric signal change of FL enhancement by ATMND and FL quenching by SGI. Under optimal conditions, the ratiometric probe exhibited a linear correlation between the intensity ratio of F408/F530 and the concentration of BLM in the range of 0.5-1000 nM, with a detection limit of 0.2 nM. In addition, the probe was applied to detect BLM in human serum samples with satisfactory results, indicating its good clinical application potential. A novel label-free ATMND/SGI based three-way junction ratiometric fluorescent probe was constructed for selective and sensitive detection of BLM.
引用
收藏
页码:2097 / 2102
页数:6
相关论文
共 33 条
  • [1] Bleomycin lung toxicity: who are the patients with increased risk?
    Azambuja, E
    Fleck, JF
    Batista, RG
    Barreto, SSM
    [J]. PULMONARY PHARMACOLOGY & THERAPEUTICS, 2005, 18 (05) : 363 - 366
  • [2] Target-induced diffusivity enhancement for rapid and highly sensitive homogeneous electrochemical detection of BLM in human serum
    Chang, Jiafu
    Gai, Panpan
    Li, Haiyin
    Li, Feng
    [J]. TALANTA, 2018, 190 : 492 - 497
  • [3] Nucleic acid recognition by metal complexes of bleomycin
    Claussen, CA
    Long, EC
    [J]. CHEMICAL REVIEWS, 1999, 99 (09) : 2797 - 2816
  • [4] Characterization of Bleomycin Cleavage Sites in Strongly Bound Hairpin DNAs
    Giroux, Rachel A.
    Hecht, Sidney M.
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2010, 132 (47) : 16987 - 16996
  • [5] Recent advances in dual-emission ratiometric fluorescence probes for chemo/biosensing and bioimaging of biomarkers
    Gui, Rijun
    Jin, Hui
    Bu, Xiangning
    Fu, Yongxin
    Wang, Zonghua
    Liu, Qingyun
    [J]. COORDINATION CHEMISTRY REVIEWS, 2019, 383 : 82 - 103
  • [6] o-Phenylenediamine/gold nanocluster-based nanoplatform for ratiometric fluorescence detection of alkaline phosphatase activity
    Han, Xue
    Meng, Zhen
    Xia, Lian
    Qu, Fengli
    Kong, Rong-Mei
    [J]. TALANTA, 2020, 212
  • [7] MECHANISMS OF BLEOMYCIN-INDUCED LUNG DAMAGE
    HAY, J
    SHAHZEIDI, S
    LAURENT, G
    [J]. ARCHIVES OF TOXICOLOGY, 1991, 65 (02) : 81 - 94
  • [8] Target-induced activation of DNAzyme for sensitive detection of bleomycin by using a simple MOF-modified electrode
    He, Yong-Qiang
    Gao, Yu
    Gu, Hui-Wen
    Meng, Xian-Zhu
    Yi, Hong-Chao
    Chen, Ying
    Sun, Wei-Yin
    [J]. BIOSENSORS & BIOELECTRONICS, 2021, 178
  • [9] Intracellular Formation of a DNA Damage-Induced, Histone Post-Translational Modification Following Bleomycin Treatment
    Jacinto, Marco Paolo
    Fried, Stephen D.
    Greenberg, Marc M.
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2022, 144 (17) : 7600 - 7605
  • [10] A universal and label-free aptasensor for fluorescent detection of ATP and thrombin based on SYBR Green I dye
    Kong, Ling
    Xu, Jin
    Xu, Yunying
    Xiang, Yun
    Yuan, Ruo
    Chai, Yaqin
    [J]. BIOSENSORS & BIOELECTRONICS, 2013, 42 : 193 - 197