Hydroxyapatite-Gold Modified Screen-Printed Carbon Electrode for Selective SARS-CoV-2 Antibody Immunosensor

被引:3
|
作者
Syafira, Ratu Shifa [1 ]
Devi, Melania Janisha [1 ]
Gaffar, Shabarni [1 ]
Kurnia, Irwan [1 ]
Arnafia, Wyanda [2 ]
Einaga, Yasuaki [3 ]
Syakir, Norman [4 ]
Noviyanti, Atiek Rostika [1 ]
Hartati, Yeni Wahyuni [1 ]
机构
[1] Padjadjaran State Univ, Fac Math & Nat Sci, Dept Chem, Sumedang 45363, West Java, Indonesia
[2] IPB Univ, Dept Anim Infect Dis & Vet Publ Hlth, Bogor 16680, West Java, Indonesia
[3] Keio Univ, Dept Chem, Yokohama 2238522, Japan
[4] Padjadjaran State Univ, Fac Math & Nat Sci, Dept Phys, Jatinangor 45363, West Java, Indonesia
关键词
Anti-RBD Spike; Electrochemical; HA-Au; immunosensor; RBD Spike; SARS-CoV-2; SPCE; NANOPARTICLES; GRAPHENE;
D O I
10.1021/acsabm.3c00953
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), or coronavirus disease 2019 (COVID-19), is still spreading worldwide; therefore, the need for rapid and accurate detection methods remains relevant to maintain the spread of this infectious disease. Electrochemical immunosensors are an alternative method for the rapid detection of the SARS-CoV-2 virus. Herein, we report the development of a screen-printed carbon electrode immunosensor using a hydroxyapatite-gold nanocomposite (SPCE/HA-Au) directly spray-coated with the immobilization receptor binding domain (RBD) Spike to increase the conductivity and surface electrode area. The HA-Au composite synthesis was optimized using the Box-Behnken method, and the resulting composite was characterized by UV-vis spectrophotometry, TEM-EDX, and XRD analysis. The specific interaction of RBD Spike with immunoglobulin G (IgG) antibodies was evaluated by differential pulse voltammetry and electrochemical impedance spectroscopy methods in a [Fe(CN)(6)](4-/3-) solution redox system. The IgG was detected with a detection limit of 0.0561 pg mL(-1), and the immunosensor had selectivity and stability of 103-122% and was stable until week 7 with the influence of storage conditions. Also, the immunosensor was tested using real samples from human serum, where the results were confirmed using the chemiluminescent microparticle immunoassay (CMIA) method and showed satisfactory results. Therefore, the developed electrochemical immunosensor can rapidly and accurately detect SARS-CoV-2 antibodies.
引用
收藏
页码:950 / 960
页数:11
相关论文
共 50 条
  • [41] A disposable label-free electrochemiluminescent immunosensor for transferrin detection based on a luminol-reduced gold nanoparticle-modified screen-printed carbon electrode
    Kong, Weijun
    Zhou, He
    Ouyang, Hui
    Li, Zongyun
    Fu, Zhifeng
    ANALYTICAL METHODS, 2014, 6 (09) : 2959 - 2964
  • [42] Ultrasensitive cholesterol biosensor based on enzymatic silver deposition on gold nanoparticles modified screen-printed carbon electrode
    Huang, Yong
    Cui, Lijie
    Xue, Yewei
    Zhang, Songbai
    Zhu, Nixuan
    Liang, Jintao
    Li, Guiyin
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2017, 77 : 1 - 8
  • [43] A modified nanostructured graphene-gold nanoparticle carbon screen-printed electrode for the sensitive voltammetric detection of rutin
    Apetrei, I. M.
    Apetrei, C.
    MEASUREMENT, 2018, 114 : 37 - 43
  • [44] A Sensitive and Selective Amperometric Immunosensor for Chloramphenicol Detection Based on Magnetic Nanocomposites Modify Screen-Printed Carbon Electrode as a Disposable Platform
    He, Guowen
    Yang, Xin
    Hu, Yongjun
    Hu, Yangjian
    Zhang, Fei
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2014, 9 (12): : 6962 - 6974
  • [45] Hg2+ detection using a disposable and miniaturized screen-printed electrode modified with nanocomposite carbon black and gold nanoparticles
    Stefano Cinti
    Francesco Santella
    Danila Moscone
    Fabiana Arduini
    Environmental Science and Pollution Research, 2016, 23 : 8192 - 8199
  • [46] Hg2+ detection using a disposable and miniaturized screen-printed electrode modified with nanocomposite carbon black and gold nanoparticles
    Cinti, Stefano
    Santella, Francesco
    Moscone, Danila
    Arduini, Fabiana
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2016, 23 (09) : 8192 - 8199
  • [47] Gold Nanoparticles Decorated on Carbon Nanotube Modified Screen-printed Electrode for Flow Injection Amperometric Determination of Methyldopa
    Upan, Jantima
    Themsirimongkon, Suwaphid
    Saipanya, Surin
    Jakmunee, Jaroon
    CHIANG MAI JOURNAL OF SCIENCE, 2019, 46 (03): : 537 - 546
  • [48] Voltammetric determination of the Escherichia coli DNA using a screen-printed carbon electrode modified with polyaniline and gold nanoparticles
    Nahid Shoaie
    Mehdi Forouzandeh
    Kobra Omidfar
    Microchimica Acta, 2018, 185
  • [49] Acetylcholinesterase sensor based on screen-printed carbon electrode modified with prussian blue
    Suprun, E
    Evtugyn, G
    Budnikov, H
    Ricci, F
    Moscone, D
    Palleschi, G
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 383 (04) : 597 - 604
  • [50] Voltammetric determination of the Escherichia coli DNA using a screen-printed carbon electrode modified with polyaniline and gold nanoparticles
    Shoaie, Nahid
    Forouzandeh, Mehdi
    Omidfar, Kobra
    MICROCHIMICA ACTA, 2018, 185 (04)