Hydroxyapatite-Gold Modified Screen-Printed Carbon Electrode for Selective SARS-CoV-2 Antibody Immunosensor

被引:3
|
作者
Syafira, Ratu Shifa [1 ]
Devi, Melania Janisha [1 ]
Gaffar, Shabarni [1 ]
Kurnia, Irwan [1 ]
Arnafia, Wyanda [2 ]
Einaga, Yasuaki [3 ]
Syakir, Norman [4 ]
Noviyanti, Atiek Rostika [1 ]
Hartati, Yeni Wahyuni [1 ]
机构
[1] Padjadjaran State Univ, Fac Math & Nat Sci, Dept Chem, Sumedang 45363, West Java, Indonesia
[2] IPB Univ, Dept Anim Infect Dis & Vet Publ Hlth, Bogor 16680, West Java, Indonesia
[3] Keio Univ, Dept Chem, Yokohama 2238522, Japan
[4] Padjadjaran State Univ, Fac Math & Nat Sci, Dept Phys, Jatinangor 45363, West Java, Indonesia
关键词
Anti-RBD Spike; Electrochemical; HA-Au; immunosensor; RBD Spike; SARS-CoV-2; SPCE; NANOPARTICLES; GRAPHENE;
D O I
10.1021/acsabm.3c00953
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), or coronavirus disease 2019 (COVID-19), is still spreading worldwide; therefore, the need for rapid and accurate detection methods remains relevant to maintain the spread of this infectious disease. Electrochemical immunosensors are an alternative method for the rapid detection of the SARS-CoV-2 virus. Herein, we report the development of a screen-printed carbon electrode immunosensor using a hydroxyapatite-gold nanocomposite (SPCE/HA-Au) directly spray-coated with the immobilization receptor binding domain (RBD) Spike to increase the conductivity and surface electrode area. The HA-Au composite synthesis was optimized using the Box-Behnken method, and the resulting composite was characterized by UV-vis spectrophotometry, TEM-EDX, and XRD analysis. The specific interaction of RBD Spike with immunoglobulin G (IgG) antibodies was evaluated by differential pulse voltammetry and electrochemical impedance spectroscopy methods in a [Fe(CN)(6)](4-/3-) solution redox system. The IgG was detected with a detection limit of 0.0561 pg mL(-1), and the immunosensor had selectivity and stability of 103-122% and was stable until week 7 with the influence of storage conditions. Also, the immunosensor was tested using real samples from human serum, where the results were confirmed using the chemiluminescent microparticle immunoassay (CMIA) method and showed satisfactory results. Therefore, the developed electrochemical immunosensor can rapidly and accurately detect SARS-CoV-2 antibodies.
引用
收藏
页码:950 / 960
页数:11
相关论文
共 50 条
  • [21] Poly(allylamine hydrochloride) modified screen-printed carbon electrode for sensitive and selective detection of NADH
    Rotariu, Lucian
    Istrate, Oana-Maria
    Bala, Camelia
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 191 : 491 - 497
  • [22] Fabrication of Hexagonal CuCoO2 Modified Screen-Printed Carbon Electrode for the Selective Electrochemical Detection of Furaltadone
    Mariappan, Kiruthika
    Chen, Tse-Wei
    Chen, Shen-Ming
    Tseng, Tien-Wen
    Bian, Yongzhong
    Sun, Ting-Ting
    Jiang, Jianzhuang
    Yu, Jaysan
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2022, 17 (05):
  • [23] Screen-printed carbon electrode-based electrochemical immunosensor for rapid detection of microalbuminuria
    Tsai, Jang-Zern
    Chen, Ching-Jung
    Settu, Kalpana
    Lin, Yu-Feng
    Chen, Chien-Lung
    Liu, Jen-Tsai
    BIOSENSORS & BIOELECTRONICS, 2016, 77 : 1175 - 1182
  • [24] Disposable graphene-oxide screen-printed electrode integrated with portable device for detection of SARS-CoV-2 in clinical samples
    Ramya, P. R.
    Halder, Sayanti
    Nagamani, K.
    Chouhan, Raghuraj Singh
    Gandhi, Sonu
    BIOELECTROCHEMISTRY, 2024, 158
  • [25] Development of highly sensitive electrochemical immunosensor based on single-walled carbon nanotube modified screen-printed carbon electrode
    Nguyen Xuan Viet
    Nguyen Xuan Hoan
    Takamura, Yuzuru
    MATERIALS CHEMISTRY AND PHYSICS, 2019, 227 : 123 - 129
  • [26] Magnetic beads combined with carbon black -based screen-printed electrodes for COVID-19: A reliable and miniaturized electrochemical immunosensor for SARS-CoV-2 detection in saliva
    Fabiani, Laura
    Saroglia, Marco
    Galata, Giuseppe
    De Santis, Riccardo
    Fillo, Silvia
    Luca, Vincenzo
    Faggioni, Giovanni
    D'Amore, Nino
    Regalbuto, Elisa
    Salvatori, Piero
    Terova, Genciana
    Moscone, Danila
    Lista, Florigio
    Arduini, Fabiana
    BIOSENSORS & BIOELECTRONICS, 2021, 171
  • [27] Electrochemical Determination of Hydrazine Based on Modified Screen-Printed Carbon Electrode
    Mohammadi, Sayed Zia
    Tajik, Somayeh
    Hamidian, Hooshang
    Mousazadeh, Farideh
    Emambakhsh, Fatemeh
    Sajadi, Pari-Sima
    Allahabadi, Hossein
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2025, 172 (01)
  • [28] Gold Microflower Modified Screen-Printed Carbon Electrode for the Electrochemical Detection of Lactic Acid in Blood and Sweat
    Krishna, Murali
    Neena, P. K.
    Pradeep, Aarathi
    Suneesh, Punathil Vasu
    Babu, T. G. Satheesh
    CHEMCATCHEM, 2024, 16 (22)
  • [29] Screen-Printed Carbon Electrode Modified with Poly-L-histidine Applied to Gold(III) Determination
    Bergamini, Marcio F.
    Santos, Daniela P.
    Zanoni, Maria Valnice B.
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2009, 20 (01) : 100 - 106
  • [30] Simple and disposable device based on gold nanoparticles modified screen-printed carbon electrode for detection of ciprofloxacin
    da Silva, Daniela Nunes
    Candido, Thais Cristina de Oliveira
    Pereira, Arnaldo Cesar
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2025, 29 (03) : 901 - 914