Hydroxyapatite-Gold Modified Screen-Printed Carbon Electrode for Selective SARS-CoV-2 Antibody Immunosensor

被引:3
|
作者
Syafira, Ratu Shifa [1 ]
Devi, Melania Janisha [1 ]
Gaffar, Shabarni [1 ]
Kurnia, Irwan [1 ]
Arnafia, Wyanda [2 ]
Einaga, Yasuaki [3 ]
Syakir, Norman [4 ]
Noviyanti, Atiek Rostika [1 ]
Hartati, Yeni Wahyuni [1 ]
机构
[1] Padjadjaran State Univ, Fac Math & Nat Sci, Dept Chem, Sumedang 45363, West Java, Indonesia
[2] IPB Univ, Dept Anim Infect Dis & Vet Publ Hlth, Bogor 16680, West Java, Indonesia
[3] Keio Univ, Dept Chem, Yokohama 2238522, Japan
[4] Padjadjaran State Univ, Fac Math & Nat Sci, Dept Phys, Jatinangor 45363, West Java, Indonesia
关键词
Anti-RBD Spike; Electrochemical; HA-Au; immunosensor; RBD Spike; SARS-CoV-2; SPCE; NANOPARTICLES; GRAPHENE;
D O I
10.1021/acsabm.3c00953
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), or coronavirus disease 2019 (COVID-19), is still spreading worldwide; therefore, the need for rapid and accurate detection methods remains relevant to maintain the spread of this infectious disease. Electrochemical immunosensors are an alternative method for the rapid detection of the SARS-CoV-2 virus. Herein, we report the development of a screen-printed carbon electrode immunosensor using a hydroxyapatite-gold nanocomposite (SPCE/HA-Au) directly spray-coated with the immobilization receptor binding domain (RBD) Spike to increase the conductivity and surface electrode area. The HA-Au composite synthesis was optimized using the Box-Behnken method, and the resulting composite was characterized by UV-vis spectrophotometry, TEM-EDX, and XRD analysis. The specific interaction of RBD Spike with immunoglobulin G (IgG) antibodies was evaluated by differential pulse voltammetry and electrochemical impedance spectroscopy methods in a [Fe(CN)(6)](4-/3-) solution redox system. The IgG was detected with a detection limit of 0.0561 pg mL(-1), and the immunosensor had selectivity and stability of 103-122% and was stable until week 7 with the influence of storage conditions. Also, the immunosensor was tested using real samples from human serum, where the results were confirmed using the chemiluminescent microparticle immunoassay (CMIA) method and showed satisfactory results. Therefore, the developed electrochemical immunosensor can rapidly and accurately detect SARS-CoV-2 antibodies.
引用
收藏
页码:950 / 960
页数:11
相关论文
共 50 条
  • [11] Electrochemiluminescence (ECL) immunosensor for detection of Francisella tularensis on screen-printed gold electrode array
    Spehar-Deleze, Anna-Maria
    Julich, Sandra
    Gransee, Rainer
    Tomaso, Herbert
    Dulay, Samuel B.
    O'Sullivan, Ciara K.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2016, 408 (25) : 7147 - 7153
  • [12] Electrochemiluminescence (ECL) immunosensor for detection of Francisella tularensis on screen-printed gold electrode array
    Anna-Maria Spehar-Délèze
    Sandra Julich
    Rainer Gransee
    Herbert Tomaso
    Samuel B. Dulay
    Ciara K. O’Sullivan
    Analytical and Bioanalytical Chemistry, 2016, 408 : 7147 - 7153
  • [13] A high sensitive impedimetric salbutamol immunosensor based on the gold nanostructure-deposited screen-printed carbon electrode
    Lin, Chia-Hung
    Wu, Ching-Chou
    Kuo, Yu-Fen
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2016, 768 : 27 - 33
  • [14] An Electrochemical Impedance Spectroscopy-Based Aptasensor for the Determination of SARS-CoV-2-RBD Using a Carbon Nanofiber-Gold Nanocomposite Modified Screen-Printed Electrode
    Tabrizi, Mahmoud Amouzadeh
    Acedo, Pablo
    BIOSENSORS-BASEL, 2022, 12 (03):
  • [15] Glucose biosensors based on a gold nanodendrite modified screen-printed electrode
    Liu, Hsi-Chien
    Tsai, Chung-Che
    Wang, Gou-Jen
    NANOTECHNOLOGY, 2013, 24 (21)
  • [16] Portable Benzo[a]pyrene Immunosensor Based on the Polyanline Nanofiber Modified Screen-printed Electrode
    Wang, Chunping
    Zhou, Jiedan
    Huang, Yibin
    Liang, Genquan
    Liu, Yingju
    Lei, Hongtao
    ADVANCED POLYMER SCIENCE AND ENGINEERING, 2011, 221 : 295 - +
  • [17] A sandwich electrochemical immunosensor for Salmonella pullorum and Salmonella gallinarum based on a screen-printed carbon electrode modified with an ionic liquid and electrodeposited gold nanoparticles
    Jianfeng Fei
    Wenchao Dou
    Guangying Zhao
    Microchimica Acta, 2015, 182 : 2267 - 2275
  • [18] A sandwich electrochemical immunosensor for Salmonella pullorum and Salmonella gallinarum based on a screen-printed carbon electrode modified with an ionic liquid and electrodeposited gold nanoparticles
    Fei, Jianfeng
    Dou, Wenchao
    Zhao, Guangying
    MICROCHIMICA ACTA, 2015, 182 (13-14) : 2267 - 2275
  • [19] Sandwich Electrochemical Immunosensor for Early Detection of Tuberculosis Based on Graphene/Polyaniline-Modified Screen-Printed Gold Electrode
    Azmi, Umi Zulaikha Mohd
    Yusof, Nor Azah
    Kusnin, Norzila
    Abdullah, Jaafar
    Suraiya, Siti
    Ong, Poh Shing
    Raston, Nurul Hanun Ahmad
    Abd Rahman, Siti Fatimah
    Fathil, Mohamad Faris Mohamad
    SENSORS, 2018, 18 (11)
  • [20] Gold nanoparticle-modified screen-printed carbon electrodes for label-free detection of SARS-CoV-2 RNA using drop casting and spray coating methods
    Zakiyyah, Salma Nur
    Satriana, Nadya Putri
    Fransisca, Natasha
    Gaffar, Shabarni
    Syakir, Norman
    Irkham
    Hartati, Yeni Wahyuni
    ADMET AND DMPK, 2025,