Contactless conductivity detector as a tool for improving universality and sensitivity of capillary electrophoresis-frontal analysis: Proof of concept

被引:0
|
作者
Brzezicka, Tatana [1 ]
Mlcochova, Hana [1 ]
Glatz, Zdenek [1 ]
Kohutova, Lenka [1 ,2 ]
机构
[1] Masaryk Univ, Fac Sci, Dept Biochem, Brno, Czech Republic
[2] Masaryk Univ, Fac Sci, Dept Biochem, Kamenice 5, Brno 62500, Czech Republic
关键词
binding constant; capillary electrophoresis-frontal analysis; contactless conductivity detection; human serum albumin; salicylic acid; PROTEIN INTERACTION; BINDING; ALBUMIN; UV;
D O I
10.1002/jssc.202300667
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Drug binding to plasma proteins influences processes such as liberation, adsorption, disposition, metabolism, and elimination of drugs, which are thus one of the key steps of a new drug development. As a result, the characterization of drug-protein interactions is an essential part of these time- and money-consuming processes. It is important to determine not only the binding strength and the stoichiometry of interaction, but also the binding site of a drug on a protein molecule, because two drugs with the same binding site can mutually affect free drug concentration. Capillary electrophoresis-frontal analysis with mobility shift affinity capillary electrophoresis is one of the most used affinity capillary electrophoresis methods for the characterization of these interactions. In this study, a well-known sensitivity problem of most capillary electrophoresis-frontal analyses using ultraviolet detection is solved by its combination with contactless conductivity detection, which provided sixfold lower limits of quantitation and detection. Binding parameters of the human serum albumin-salicylic acid model affinity pair were evaluated by this newly developed approach and by the classical approach with ultraviolet detection primarily used for their mutual comparison. The results of both approaches agreed well and are also in agreement with literature data obtained using different techniques.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Contactless conductivity detector for microchip capillary electrophoresis
    Pumera, M
    Wang, J
    Opekar, F
    Jelínek, I
    Feldman, J
    Löwe, H
    Hardt, S
    ANALYTICAL CHEMISTRY, 2002, 74 (09) : 1968 - 1971
  • [2] Contactless conductivity detector for capillary electrophoresis chip
    Liu, Xiao-Wei
    Zhang, Hai-Feng
    Shao, Xian-Hui
    Li, Ling
    Peng, Zhi-Cheng
    Nami Jishu yu Jingmi Gongcheng/Nanotechnology and Precision Engineering, 2009, 7 (02): : 123 - 126
  • [3] Contactless conductivity detector array for capillary electrophoresis
    Stojkovic, Marko
    Koenka, Israel Joel
    Thormann, Wolfgang
    Hauser, Peter C.
    ELECTROPHORESIS, 2014, 35 (04) : 482 - 486
  • [4] Study on Drug Displacement Interactions by Capillary Electrophoresis-Frontal Analysis
    Zhou Dawei
    Wang Huaifeng
    Li Famei
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2005, 23 (02) : 186 - 188
  • [5] Binding analysis of nilvadipine to plasma lipoproteins by capillary electrophoresis-frontal analysis
    Mohamed, NAL
    Kuroda, Y
    Shibukawa, A
    Nakagawa, T
    El Gizawy, S
    Askal, HF
    El Kommos, ME
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1999, 21 (05) : 1037 - 1043
  • [6] Application of an external contactless conductivity detector for the analysis of beverages by microchip capillary electrophoresis
    Kubán, P
    Hauser, PC
    ELECTROPHORESIS, 2005, 26 (16) : 3169 - 3178
  • [7] Design of Movable Contactless Conductivity Detector for Microchip Capillary Electrophoresis
    Zhang, Hai-feng
    Liui, Xiao-wei
    Peng, Zhi-cheng
    Wang, Xi-lian
    Wang, Wei
    Chen, Yu-feng
    2009 4TH IEEE INTERNATIONAL CONFERENCE ON NANO/MICRO ENGINEERED AND MOLECULAR SYSTEMS, VOLS 1 AND 2, 2009, : 190 - +
  • [8] Integrated Capacitively Coupled Contactless Conductivity Detector for Capillary Electrophoresis
    Wang Lixin
    Fu Chonggang
    PROCEEDINGS OF THE SECOND INTERNATIONAL SYMPOSIUM ON TEST AUTOMATION & INSTRUMENTATION, VOL. 3, 2008, : 1493 - 1495
  • [9] Effect of the Detector Parameters on the Sensitivity of Contactless Conductivity Detector for Micrchip electrophoresis
    Zhang, Haifeng
    Liu, Xiaowei
    Li, Haitao
    Wang, Xilian
    7TH INTERNATIONAL CONFERENCE ON SYSTEM SIMULATION AND SCIENTIFIC COMPUTING ASIA SIMULATION CONFERENCE 2008, VOLS 1-3, 2008, : 355 - +
  • [10] Enantioselective binding analysis of verapamil to plasma lipoproteins by capillary electrophoresis-frontal analysis
    Mohamed, NAL
    Kuroda, Y
    Shibukawa, A
    Nakagawa, T
    El Gizawy, S
    Askal, HF
    El Kommos, ME
    JOURNAL OF CHROMATOGRAPHY A, 2000, 875 (1-2) : 447 - 453