Accuracy and Potential Interferences of Continuous Glucose Monitoring Sensors in the Hospital

被引:14
作者
Bellido, Virginia [1 ,2 ]
Freckman, Guido [3 ]
Perez, Antonio [4 ]
Galindo, Rodolfo J. [5 ,6 ]
机构
[1] Hosp Univ Virgen del Rocio, Unidad Gest Clin Endocrinol & Nutr, Seville, Spain
[2] Univ Seville, Hosp Univ Virgen del Rocio, Inst Biomed Sevilla IBiS, CSIC, Seville, Spain
[3] Univ Ulm, Inst Diabet Technol, Forsch & Entwicklungsgesell mbH, Ulm, Germany
[4] Univ Autonoma Barcelona, Hosp St Creu i St Pau, Serv Endocrinol & Nutr, IIB St Pau,CIBER Diabet & Enfermedades Metab Asoc, Barcelona, Spain
[5] Univ Miami, Miller Sch Med, Div Endocrinol Diabet & Metab, Miami, FL USA
[6] Univ Miami, Miller Sch Med, Div Endocrinol Diabet & Metab, Med, 1450 NW 10th Ave, Suite 202, Miami, FL 33136 USA
关键词
Accuracy; CGM; glucose monitoring; inpatient diabetes; INTENSIVE-CARE-UNIT; CRITICALLY-ILL PATIENTS; OPERATING-ROOM; SYSTEM; PERFORMANCE; CGM; SAFETY; IMPLEMENTATION; FEASIBILITY; EVERSENSE;
D O I
10.1016/j.eprac.2023.06.007
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
For years, the standard of care for monitoring dysglycemia in hospitalized patients was capillary blood glucose (CBG) testing with point-of-care glucose meters. Recently, there has been a revolution in novel factory-calibrated continuous glucose monitoring (CGM) systems. Newer CGMs are smaller and less expensive, have improved accuracy and longer wear time, and do not require fingerstick CBG for calibration, resulting in increased utilization in ambulatory settings. Consequently, hospitals have noticed increased usability of CGMs among hospitalized patients and expect a progressive continued increase. During the COVID-19 pandemic, there was a critical need for innovative approaches to glycemic monitoring, with several pilot implementation projects using CGM in the intensive care unit and non-intensive care unit settings, further boosting the evidence in this area. Hence, recent guidelines have provided recommendations for the use of CGM in specific hospital scenarios and highlighted the potential of CGM to overcome CBG limitations for glucose monitoring in the inpatient setting. In this review, we provide the following: 1) an up-to-date review of the accuracy of the newer CGMs in hospitalized patients, 2) a discussion of standards for CGM accuracy metrics, 3) a contemporary overview of potential interferences that may cause inaccuracies or poor CGM performance, and 4) required steps for full regulatory approval of CGMs in the hospital and future research steps to advance the field forward. (c) 2023 AACE. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:919 / 927
页数:9
相关论文
共 97 条
  • [1] Continuous Glucose Monitoring in the Intensive Care Unit During the COVID-19 Pandemic
    Agarwal, Shivani
    Mathew, Justin
    Davis, Georgia M.
    Shephardson, Alethea
    Levine, Ann
    Louard, Rita
    Urrutia, Agustina
    Perez-Guzman, Citlalli
    Umpierrez, Guillermo E.
    Peng, Limin
    Pasquel, Francisco J.
    [J]. DIABETES CARE, 2021, 44 (03) : 847 - 849
  • [2] Ancona P, 2017, CRIT CARE RESUSC, V19, P167
  • [3] Continuous Glucose Monitoring Within Hospital: A Scoping Review and Summary of Guidelines From the Joint British Diabetes Societies for Inpatient Care
    Avari, Parizad
    Lumb, Alistair
    Flanagan, Daniel
    Rayman, Gerry
    Misra, Shivani
    Dhatariya, Ketan
    Choudhary, Pratik
    [J]. JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2023, 17 (03): : 611 - 624
  • [4] The Performance and Usability of a Factory-Calibrated Flash Glucose Monitoring System
    Bailey, Timothy
    Bode, Bruce W.
    Christiansen, Mark P.
    Klaff, Leslie J.
    Alva, Shridhara
    [J]. DIABETES TECHNOLOGY & THERAPEUTICS, 2015, 17 (11) : 787 - 794
  • [5] Landscape of Continuous Glucose Monitoring (CGM) and Integrated CGM: Accuracy Considerations
    Bailey, Timothy S.
    Alva, Shridhara
    [J]. DIABETES TECHNOLOGY & THERAPEUTICS, 2021, 23 : S5 - S11
  • [6] Evaluation of the performance of a new OptiScanner™ 5000 system for an intermittent glucose monitoring
    Barassi, Alessandra
    Umbrello, Michele
    Ghilardi, Francesca
    Damele, Clara Anna Linda
    Massaccesi, Luca
    Iapichino, Gaetano
    d'Eril, Gian Vico Melzi
    [J]. CLINICA CHIMICA ACTA, 2015, 438 : 252 - 254
  • [7] Basu Ananda, 2017, J Diabetes Sci Technol, V11, P936, DOI 10.1177/1932296817697329
  • [8] Direct Evidence of Acetaminophen Interference with Subcutaneous Glucose Sensing in Humans: A Pilot Study
    Basu, Ananda
    Veettil, Sona
    Dyer, Roy
    Peyser, Thomas
    Basu, Rita
    [J]. DIABETES TECHNOLOGY & THERAPEUTICS, 2016, 18 : 43 - 47
  • [9] Basu Ananda, 2015, J Diabetes Sci Technol, V9, P63, DOI 10.1177/1932296814554797
  • [10] Bliss C, 2020, UNDERSEA HYPERBAR M, V47, P13, DOI 10.22462/01.03.2020.2