Prostate magnetic resonance imaging and the value of experience: An intrareader variability study

被引:0
作者
Whish-Wilson, Thomas [1 ,2 ]
Tan, Jo-Lynn [1 ]
Cross, William [3 ]
Wong, Lih-Ming [1 ,2 ]
Sutherland, Tom [3 ,4 ]
机构
[1] St Vincents Hosp Melbourne, Dept Surg, 41 Victoria Pde, Fitzroy, Vic 3065, Australia
[2] Univ Melbourne, Dept Surg, Melbourne, Vic, Australia
[3] Univ Melbourne, Fac Med, Melbourne, Vic, Australia
[4] St Vincents Hosp Melbourne, Med Imaging Dept, 41 Victoria Pde, Fitzroy, Vic, Australia
关键词
Prostate cancer; Magnetic resonance imaging; Prostate Imaging-Reporting and Data System; Intrareader; Prostate biopsy; CANCER; BIOPSY; MRI;
D O I
10.1016/j.ajur.2021.08.002
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Objective: To measure the intraobserver concordance of an experienced genitourinary radiologist reporting of multiparametric magnetic resonance imaging of the prostate (mpMRIp) scans over time.Methods: An experienced genitourinary radiologist re-reported his original 100 consecutive mpMRIp scans using Prostate Imaging-Reporting and Data System version 2 (PI-RADS v2) after 5 years of further experience comprising >1000 scans. Intraobserver agreement was measured using Cohen's kappa. Sensitivity, specificity, negative predictive value (NPV), positive predictive value (PPV), and accuracy were calculated, and comparison of sensitivity was performed using McNemar's test.Results: Ninety-six mpMRIp scans were included in our final analysis. Of the 96 patients, 53 (55.2%) patients underwent subsequent biopsy (n=43) or prostatectomy (n=15), with 73 lesions targeted. Moderate agreement (Cohen's kappa 0.55) was seen in the number of lesions identified at initial reporting and on re-reading (81 vs. 39 total lesions; and 71 vs. 37 number of PI-RADS >= 3 lesions). For clinically significant prostate cancer, re-reading demonstrated an increase in specificity (from 43% to 89%) and PPV (from 62% to 87%), but a decrease in sensitivity (from 94% to 72%, p=0.01) and NPV (from 89% to 77%).Conclusion: The intraobserver agreement for a novice to experienced radiologist reporting mpMRIp using PI-RADS v2 is moderate. Reduced sensitivity is off-set by improved specificity and PPV, which validate mpMRIp as a gold standard for prebiopsy screening.(c) 2023 Editorial Office of Asian Journal of Urology. Production and hosting by Elsevier B.V. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/ licenses/by-nc-nd/4.0/).
引用
收藏
页码:488 / 493
页数:6
相关论文
共 23 条
[1]   Diagnostic accuracy of multi-parametric MRI and TRUS biopsy in prostate cancer (PROMIS): a paired validating confirmatory study [J].
Ahmed, Hashim U. ;
Bosaily, Ahmed El-Shater ;
Brown, Louise C. ;
Gabe, Rhian ;
Kaplan, Richard ;
Parmar, Mahesh K. ;
Collaco-Moraes, Yolanda ;
Ward, Katie ;
Hindley, Richard G. ;
Freeman, Alex ;
Kirkham, Alex P. ;
Oldroyd, Robert ;
Parker, Chris ;
Emberton, Mark .
LANCET, 2017, 389 (10071) :815-822
[2]   Characteristics of missed prostate cancer lesions on 3T multiparametric-MRI in 518 patients: based on PI-RADSv2 and using whole-mount histopathology reference [J].
Bajgiran, Amirhossein Mohammadian ;
Mirak, Sohrab Afshari ;
Shakeri, Sepideh ;
Felker, Ely R. ;
Ponzini, Danielle ;
Ahuja, Preeti ;
Sisk, Anthony E. ;
Lu, David S. ;
Raman, Steven S. .
ABDOMINAL RADIOLOGY, 2019, 44 (03) :1052-1061
[3]   ESUR prostate MR guidelines 2012 [J].
Barentsz, Jelle O. ;
Richenberg, Jonathan ;
Clements, Richard ;
Choyke, Peter ;
Verma, Sadhna ;
Villeirs, Geert ;
Rouviere, Olivier ;
Logager, Vibeke ;
Futterer, Jurgen J. .
EUROPEAN RADIOLOGY, 2012, 22 (04) :746-757
[4]   Fusion US/MRI prostate biopsy using a computer aided diagnostic (CAD) system [J].
Ferriero, Mariaconsiglia ;
Anceschi, Umberto ;
Bove, Alfredo M. ;
Bertini, Luca ;
Flammia, Rocco S. ;
Zeccolini, Guglielmo ;
De Concilio, Bernardino ;
Tuderti, Gabriele ;
Mastroianni, Riccardo ;
Misuraca, Leonardo ;
Brassetti, Aldo ;
Guaglianone, Salvatore ;
Gallucci, Michele ;
Celia, Antonio ;
Simone, Giuseppe .
MINERVA UROLOGY AND NEPHROLOGY, 2021, 73 (05) :616-624
[5]   Can Clinically Significant Prostate Cancer Be Detected with Multiparametric Magnetic Resonance Imaging? A Systematic Review of the Literature [J].
Futterer, Jurgen J. ;
Briganti, Alberto ;
De Visschere, Pieter ;
Emberton, Mark ;
Giannarini, Gianluca ;
Kirkham, Alex ;
Taneja, Samir S. ;
Thoeny, Harriet ;
Villeirs, Geert ;
Villers, Arnauld .
EUROPEAN UROLOGY, 2015, 68 (06) :1045-1053
[6]   Interreader agreement of PI-RADS v. 2 in assessing prostate cancer with multiparametric MRI: A study using whole-mount histology as the standard of reference [J].
Girometti, Rossano ;
Giannarini, Gianluca ;
Greco, Franco ;
Isola, Miriam ;
Cereser, Lorenzo ;
Como, Giuseppe ;
Sioletic, Stefano ;
Pizzolitto, Stefano ;
Crestani, Alessandro ;
Ficarra, Vincenzo ;
Zuiani, Chiara .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2019, 49 (02) :546-555
[7]   Interreader Variability of Prostate Imaging Reporting and Data System Version 2 in Detecting and Assessing Prostate Cancer Lesions at Prostate MRI [J].
Budovec, Joseph J. ;
Mulligan, Margaret ;
Mautz, Alan .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2019, 212 (06) :1205-1205
[8]   Computer-aided diagnosis prior to conventional interpretation of prostate mpMRI: an international multi-reader study [J].
Greer, Matthew D. ;
Lay, Nathan ;
Shih, Joanna H. ;
Barrett, Tristan ;
Bittencourt, Leonardo Kayat ;
Borofsky, Samuel ;
Kabakus, Ismail ;
Law, Yan Mee ;
Marko, Jamie ;
Shebel, Haytham ;
Mertan, Francesca V. ;
Merino, Maria J. ;
Wood, Bradford J. ;
Pinto, Peter A. ;
Summers, Ronald M. ;
Choyke, Peter L. ;
Turkbey, Baris .
EUROPEAN RADIOLOGY, 2018, 28 (10) :4407-4417
[9]   Comparison of initial and tertiary centre second opinion reads of multiparametric magnetic resonance imaging of the prostate prior to repeat biopsy [J].
Hansen, Nienke L. ;
Koo, Brendan C. ;
Gallagher, Ferdia A. ;
Warren, Anne Y. ;
Doble, Andrew ;
Gnanapragasam, Vincent ;
Bratt, Ola ;
Kastner, Christof ;
Barrett, Tristan .
EUROPEAN RADIOLOGY, 2017, 27 (06) :2259-2266
[10]   MRI-Targeted Biopsy for Prostate-Cancer Diagnosis [J].
Martini, Alberto ;
Cumarasamy, Shivaram ;
Tewari, Ash K. .
NEW ENGLAND JOURNAL OF MEDICINE, 2018, 379 (06) :589-589