Hemodynamic monitoring and correlation between electrical cardiometry and esophageal Doppler in patients undergoing major abdominal surgery

被引:0
作者
Abdalla, Shady Rady [1 ]
Abdelazeem, Ahmed Salah [1 ]
Kaddah, Tarek Abdelhalium [1 ]
Elhadedy, Abla Salah [1 ]
Khafagy, Hanan Farouk [1 ]
Mohamed, Ahmed Abdalla [1 ]
Essam, Ahmed Mohamed [1 ]
机构
[1] Theodor Bilharz Res Inst, Intens Care & Pain Management Dept, Anesthesia, Giza, Egypt
来源
EGYPTIAN JOURNAL OF ANAESTHESIA | 2023年 / 39卷 / 01期
关键词
Hemodynamic monitoring; electrical cardiometry; esophageal Doppler; abdominal surgery; TRANSESOPHAGEAL DOPPLER; CARDIAC-OUTPUT; FLUID MANAGEMENT; ACCURACY; CHILDREN; TIME;
D O I
10.1080/11101849.2023.2209415
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Transesophageal Doppler (TED) is a minimally invasive monitor that allows continuous hemodynamic variables monitoring. Non-invasive electrical cardiometry (EC) and TED methods added an additional facility to monitor cardiac output (CO) continuously and guide fluid management. The aim of this study was to correlate hemodynamic monitoring between non-invasive EC and Esophageal Doppler (ED) in cases undergoing major abdominal surgery. Methods: This prospective observational study was carried out on 35 adult cases, American Society of Anesthesiologists (ASA) physical status II or III, undergoing major abdominal surgery. Esophageal Doppler and EC were attached to the same patient. Parameters measured were hemodynamic parameters. Results: Comparison of CO with ICON and ED showed that the ICON mean value ranged from 5.6 to 6.2 l/min, and the ED mean value always ranged from 5.7 to 7.6 l/min with the non-significant difference between the two methods. The precision for the ICON ranged from 15.19 to 17.99% and the precision for ED ranged from 13.39 to 17.08%. At a 15% change in ICON, the ED values' sensitivity was 72.6% and specificity was 30.9% with AUC 0.505. Conclusion: The agreement between CO measured by EC and ED is acceptable. Both monitored trend changes and guided fluid administration in the operation theater. The EC is as accurate as ED in measuring hemodynamics during major abdominal surgery.
引用
收藏
页码:418 / 425
页数:8
相关论文
共 50 条
  • [41] Postoperative management of patients undergoing cardiac surgery in Austria: A national survey on current clinical practice in hemodynamic monitoring and postoperative management
    Menger, Johannes
    Edlinger-Stanger, Maximilian
    Dworschak, Martin
    Steinlechner, Barbara
    WIENER KLINISCHE WOCHENSCHRIFT, 2018, 130 (23-24) : 716 - 721
  • [42] Continuous Glucose Monitoring Reveals Perioperative Hypoglycemia in Most Patients With Diabetes Undergoing Major Surgery A Prospective Cohort Study
    Carlsson, Christian J.
    Norgaard, Kirsten
    Oxboll, Anne-Britt
    Sogaard, Mette I. V.
    Achiam, Michael P.
    Jorgensen, Lars N.
    Eiberg, Jonas P.
    Palm, Henrik
    Sorensen, Helge B. D.
    Meyhof, Christian S.
    Aasvang, Eske K.
    ANNALS OF SURGERY, 2023, 277 (04) : 603 - 611
  • [43] Association Between Plasma Amyloid-Beta 42 Ratio and Postoperative Delirium in Elderly Patients Undergoing Major Abdominal Surgery: Secondary Analysis of a Randomized Controlled Trial
    Fan, Qianqian
    Wang, Yonghui
    Lu, Zhihong
    Wang, Lini
    Yang, Xue
    Zheng, Ziyu
    Dong, Hailong
    Xiong, Lize
    Lei, Chong
    BRAIN AND BEHAVIOR, 2025, 15 (04):
  • [44] Effect of fluid strategy on stroke volume, cardiac output, and fluid responsiveness in adult patients undergoing major abdominal surgery: a sub-study of the Restrictive versus Liberal Fluid Therapy in Major Abdominal Surgery (RELIEF) trial
    Phan, Tuong D.
    Uda, Yoshiaki
    Peyton, Philip J.
    Kluger, Roman
    Myles, Paul S.
    BRITISH JOURNAL OF ANAESTHESIA, 2021, 126 (04) : 818 - 825
  • [45] Relationship Between Plethysmographic Waveform Changes and Hemodynamic Variables in Anesthetized, Mechanically Ventilated Patients Undergoing Continuous Cardiac Output Monitoring
    Thiele, Robert H.
    Colquhoun, Douglas A.
    Patrie, James
    Nie, Sarah H.
    Huffmyer, Julie L.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2011, 25 (06) : 1044 - 1050
  • [46] Meta-analysis of goal-directed fluid therapy using transoesophageal Doppler monitoring in patients undergoing elective colorectal surgery
    Rollins, K. E.
    Mathias, N. C.
    Lobo, D. N.
    BJS OPEN, 2019, 3 (05): : 606 - 616
  • [47] Dopexamine Has No Additional Benefit in High-Risk Patients Receiving Goal-Directed Fluid Therapy Undergoing Major Abdominal Surgery
    Davies, Simon J.
    Yates, David
    Wilson, R. Jonathan T.
    ANESTHESIA AND ANALGESIA, 2011, 112 (01) : 130 - 138
  • [48] Continuous Non-invasive finger cuff CareTaker® comparable to invasive intraarterial pressure in patients undergoing major intra-abdominal surgery
    Gratz, Irwin
    Deal, Edward
    Spitz, Francis
    Baruch, Martin
    Allen, I. Elaine
    Seaman, Julia E.
    Pukenas, Erin
    Jean, Smith
    BMC ANESTHESIOLOGY, 2017, 17
  • [49] Can perioperative pCO2 gaps predict complications in patients undergoing major elective abdominal surgery randomized to goal-directed therapy or standard care? A secondary analysis
    Ilonka N. de Keijzer
    Thomas Kaufmann
    Eric E.C. de Waal
    Michael Frank
    Dianne de Korte-de Boer
    Leonard M. Montenij
    Wolfgang Buhre
    Thomas W.L. Scheeren
    Journal of Clinical Monitoring and Computing, 2024, 38 : 469 - 477
  • [50] Fried Frailty Phenotype Questionnaire scores and postoperative patient-reported outcomes of patients undergoing major abdominal cancer surgery: A secondary analysis