A semi-automated robotic system for percutaneous interventions

被引:1
|
作者
Siegfarth, Marius [1 ]
Lutz, Raffael [1 ]
Iseke, Nils-Christian [1 ]
Moviglia, Javier [1 ]
Sadi, Fabian [1 ]
Stallkamp, Jan [1 ]
机构
[1] Heidelberg Univ, Mannheim Inst Intelligent Syst Med, Mannheim, Germany
关键词
Medical robotics; Interventional radiology; CT robot; Percutaneous intervention; CT;
D O I
10.1007/s11548-023-02882-6
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
PurposeA robotic assistive device is developed for needle-based percutaneous interventions. The aim is a hybrid system using both manual and actuated robotic operation in order to obtain a device that has a large workspace but can still fit in the gantry opening of a CT scanner. This will enable physicians to perform precise and time-efficient CT-guided percutaneous interventions. The concept of the mechanics and software of the device is presented in this work.MethodsThe approach is a semi-automated robotic assistive device, which combines manual and robotic positioning to reduce the number and size of necessary motors. The system consists of a manual rough positioning unit, a robotic fine positioning unit and an optical needle tracking unit. The resulting system has eight degrees of freedom, of which four are manual, which comprise encoders to monitor the position of each axis. The remaining four axes are actuated axes for fine positioning of the needle. Cameras are attached to the mechanical structure for 3D tracking of the needle pose. The software is based on open-source software, mainly ROS2 as robotic middleware, Moveit2 for trajectory calculation and 3D Slicer for needle path planning.ResultsThe communication between the components was successfully tested with a clinical CT scanner. In a first experiment, four needle insertions were planned and the deviation of the actual needle path from the planned path was measured. The mean deviation from the needle path to the target point was 21.9 mm, which is mainly caused both by translational deviation (15.4 mm) and angular deviation (6.8 degrees) of the needle holder. The optical tracking system was able to detect the needle position with a mean deviation of 3.9 mm.ConclusionThe first validation of the system was successful which proves that the proposed concept for both the hardware and software is feasible. In a next step, an automatic position correction based on the optical tracking system will be integrated, which is expected to significantly improve the system accuracy.
引用
收藏
页码:1571 / 1575
页数:5
相关论文
共 50 条
  • [31] A COMPACT MICROWAVE SYSTEM FOR RAPID, SEMI-AUTOMATED RADIOSYNTHESES
    Olma, S.
    Lambert, J.
    Barnhardt, E.
    Liu, K.
    Shen, C.
    van Dam, R.
    JOURNAL OF LABELLED COMPOUNDS & RADIOPHARMACEUTICALS, 2009, 52 : S509 - S509
  • [32] A semi-automated system for the characterization of NLC accelerating structures
    Hanna, SM
    Bowden, GB
    Hoag, HA
    Loewen, R
    Vlieks, AE
    Wang, JW
    PROCEEDINGS OF THE 1995 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-5, 1996, : 1108 - 1110
  • [33] Design and evaluation of a semi-automated site modeling system
    Hsieh, Y
    IMAGE UNDERSTANDING WORKSHOP, 1996 PROCEEDINGS, VOLS I AND II, 1996, : 435 - 459
  • [34] A SEMI-AUTOMATED DETERMINATION OF PHOSPHOLIPIDS
    KRAML, M
    CLINICA CHIMICA ACTA, 1966, 13 (04) : 442 - &
  • [35] Semi-Automated Intelligent Systems
    Chinam, Srihari Akash
    Reddy, N. V. Subba
    Prema, K., V
    2017 INTERNATIONAL CONFERENCE ON ADVANCES IN COMPUTING, COMMUNICATIONS AND INFORMATICS (ICACCI), 2017, : 110 - 115
  • [36] Semi-Automated Analysis of a Thesis
    Mason, Oliver
    Pennington, Martha C.
    WRITING & PEDAGOGY, 2009, 1 (02): : 303 - 326
  • [37] Semi-Automated Analog Placement
    Lao, Eric
    Louerat, Marie-Minerve
    Chaput, Jean-Paul
    23RD IEEE INTERNATIONAL CONFERENCE ON ELECTRONICS CIRCUITS AND SYSTEMS (ICECS 2016), 2016, : 432 - 433
  • [38] Semi-Automated Data Labeling
    Desmond, Michael
    Duesterwald, Evelyn
    Brimijoin, Kristina
    Brachman, Michelle
    Pan, Qian
    NEURIPS 2020 COMPETITION AND DEMONSTRATION TRACK, VOL 133, 2020, 133 : 156 - 169
  • [39] Semi-automated blastocyst microinjection
    Mattos, Leonardo
    Grant, Edward
    Thresher, Randy
    2006 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), VOLS 1-10, 2006, : 1780 - +
  • [40] Semi-Automated Video Morphing
    Liao, Jing
    Lima, Rodolfo S.
    Nehab, Diego
    Hoppe, Hugues
    Sander, Pedro V.
    COMPUTER GRAPHICS FORUM, 2014, 33 (04) : 51 - 60