Patient radiation exposure dose reduction using stent-enhanced image processing in percutaneous coronary intervention

被引:0
作者
Mori, Kazuya [1 ,2 ]
Negishi, Toru [2 ]
Makabe, Kouhei [1 ]
Sekiguchi, Ryou [1 ]
Tsuchida, Takuji [1 ]
机构
[1] Saiseikai Kawaguchi Gen Hosp, Dept Radiol Technol, 5-11-5 Nishikawaguchi, Kawaguchi, Saitama 3328558, Japan
[2] Tokyo Metropolitan Univ, Grad Sch Human Hlth Sci, Dept Radiol Sci, 7-2-10 Higashi Ogu, Arakawa, Tokyo 1168551, Japan
关键词
Interventional radiology; Radiation exposure dose; Percutaneous coronary intervention; Stent enhancement processing;
D O I
10.1007/s12194-024-00796-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We investigated the reduction in patient radiation exposure dose during percutaneous coronary intervention (PCI) by stent enhancement processing. We examined the effects of dose reduction based on the image quality of stent enhancement processing using a purpose-built dynamic phantom. We evaluated the image contrast (IC) of the stent in stent-enhanced images (SVref), digital angiography (DA), and stent-enhanced images with a 20%, 40%, and 60% lower imaging doses (SV20, SV40, and SV60). We visually evaluated graininess and stent shape using the mean opinion score (MOS) and retrospectively evaluated the acquisition duration of stent enhancement in PCI cases; finally, we estimated the decrease in patient radiation exposure due to stent enhancement. The image contrast of SVref at phantom thicknesses of 20 cm was 51.25 +/- 3.82, while the image contrast of DA was significantly reduced at 14.90 +/- 1.57 (p < 0.05). We observed a significant decrease in the MOS of graininess in SV60 and MOS of stent shape in DA (p < 0.05). Furthermore, the average imaging duration for stent enhancement using PCI was 22.65 +/- 7.43 s, and the maximum imaging duration was 68.07 s. We hypothesize that patient radiation exposure dose can be reduced by up to 60.17 mGy by lowering the imaging dose during the stent enhancement process. Stent enhancement processing improves the visibility of stent images, and can reduce radiation exposure by approximately 40% during confirmation imaging of stents. Our study contributes to the reduction of radiation exposure dose for operators and patients in PCI.
引用
收藏
页码:433 / 440
页数:8
相关论文
共 50 条
  • [1] Investigation of patient radiation exposure reduction through optimization of imaging conditions for stent enhancement processing in percutaneous coronary intervention: a retrospective study
    Kazuya Mori
    Toru Negishi
    Kouhei Makabe
    Kazuhisa Matsukura
    Radiological Physics and Technology, 2025, 18 (2) : 615 - 621
  • [2] Impact of Patient BMI on Patient and Operator Radiation Dose During Percutaneous Coronary Intervention
    Crowhurst, James
    Savage, Michael
    Hay, Karen
    Murdoch, Dale
    Aroney, Nicholas
    Dautov, Rustem
    Walters, Darren L.
    Raffel, Owen Christopher
    HEART LUNG AND CIRCULATION, 2022, 31 (03) : 372 - 382
  • [3] Comparison of radiation dose exposure in patients undergoing percutaneous coronary intervention vs. peripheral intervention
    Arif, Salech
    Bartus, Stanislaw
    Rakowski, Tomasz
    Bobrowska, Beata
    Rutka, Joanna
    Zabowka, Anna
    Tokarek, Tomasz
    Dudek, Dariusz
    Dubiel, Jacek
    POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2014, 10 (04): : 308 - 313
  • [4] Impact of StentBoost subtract imaging on patient radiation exposure during percutaneous coronary intervention
    Jin, Zhigeng
    Yang, Shengli
    Jing, Limin
    Liu, Huiliang
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (06) : 1207 - 1213
  • [5] Impact of StentBoost subtract imaging on patient radiation exposure during percutaneous coronary intervention
    Zhigeng Jin
    Shengli Yang
    Limin Jing
    Huiliang Liu
    The International Journal of Cardiovascular Imaging, 2013, 29 : 1207 - 1213
  • [6] Enhanced stent visualization system for percutaneous coronary intervention in patients with chronic kidney disease: effects on contrast media volume and radiation exposure
    Tian, Yunpeng
    Zhao, Xiangdong
    Yang, Yang
    Cai, Xiaoshu
    Jian, Lian
    Guo, Suzhen
    Xia, Dasheng
    Chen, Xin
    Li, Chao
    Guo, Qianyu
    Chen, Bingwei
    Lu, Chengzhi
    BMC CARDIOVASCULAR DISORDERS, 2022, 22 (01)
  • [7] Enhanced stent visualization system for percutaneous coronary intervention in patients with chronic kidney disease: effects on contrast media volume and radiation exposure
    Yunpeng Tian
    Xiangdong Zhao
    Yang Yang
    Xiaoshu Cai
    Lian Jian
    Suzhen Guo
    Dasheng Xia
    Xin Chen
    Chao Li
    Qianyu Guo
    Bingwei Chen
    Chengzhi Lu
    BMC Cardiovascular Disorders, 22
  • [8] Time-Course Reduction in Patient Exposure to Radiation From Coronary Interventional Procedures The Greater Paris Area Percutaneous Coronary Intervention Registry
    Georges, Jean-Louis
    Karam, Nicole
    Tafflet, Muriel
    Livarek, Bernard
    Bataille, Sophie
    Loyeau, Aurelie
    Mapouata, Mireille
    Benamer, Hakim
    Caussin, Christophe
    Garot, Philippe
    Varenne, Olivier
    Barbou, Franck
    Teiger, Emmanuel
    Funck, Francois
    Karrillon, Gaetan
    Lambert, Yves
    Spaulding, Christian
    Jouven, Xavier
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2017, 10 (08)
  • [9] Radiation Dose in Percutaneous Coronary Intervention OUCH ... Did That Hurt?
    Chambers, Charles E.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2011, 4 (03) : 344 - 346
  • [10] Image Processing Based Autonomous Guidewire Navigation in Percutaneous Coronary Intervention
    Cho, Yongjun
    Park, Jae-Hyeon
    Choi, Jaesoon
    Chang, Dong Eui
    2021 IEEE INTERNATIONAL CONFERENCE ON CONSUMER ELECTRONICS-ASIA (ICCE-ASIA), 2021,