Energy Performance Analysis of a Solar Refrigerator Using Ecological Refrigerants

被引:8
作者
Amaris, Carlos [1 ]
Barbosa, Fabia [2 ,3 ]
Balbis-Morejon, Milen [2 ]
机构
[1] Univ Ind St ander, Sch Mech Engn, Carrera 27 Calle 9, Bucaramanga 680002, Colombia
[2] Univ Costa, Energy Dept, Cl 58 55-66, Barranquilla 080002, Colombia
[3] Univ Popular Cesar, Dept Agroind Sci, Carrera 40 Via Mar, Valledupar 205010, Colombia
来源
JOURNAL OF SUSTAINABLE DEVELOPMENT OF ENERGY WATER AND ENVIRONMENT SYSTEMS-JSDEWES | 2023年 / 11卷 / 03期
关键词
Ecological refrigerants; R600a; R290; Energy and exergy analysis; Solar refrigeration system; INTERNAL HEAT-EXCHANGER; PHOTOVOLTAIC DC REFRIGERATOR; SYSTEM; ALTERNATIVES; SIMULATION; R1234ZE(E); R1234YF; OPTIONS; DESIGN; R290;
D O I
10.13044/j.sdewes.d11.0446
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The development of sustainable energy technologies must be a priority given the rising global energy demand and global warming gases emission. In this work, the energy evaluation of a small-capacity direct-current refrigerator with internal heat exchange using R600a, R290, R717, and R134a as a base case, for autonomous solar refrigeration, is discussed. A thermodynamic model was developed to assess a 200 W refrigerator performance at evaporation temperatures of-32/-10 degrees C, condensation temperatures of 35/46 degrees C, and different internal heat exchanger effectiveness values while considering the environmental conditions in the city of Barranquilla whose metropolitan and urban area presents a great potential for solar refrigeration. Results showed that the R290 system coefficient of performance was up to 2.6% higher than that of the R134a. The R600a system coefficient of performance was up to 2.7% higher than that of the R134a, but only under the most favourable conditions. The R717 system surpassed the compressor discharge temperature limits so it was found unsuitable for the present application. Moreover, the internal heat exchanger was found beneficial to reduce the exergy destruction in the compressor and expansion valve but increased that in the condenser for R134a, R600a, and R290. The internal heat exchanger recommended effectiveness should be around 0.4 for R600a or 0.3 for R290 at an evaporation temperature of-32 degrees C. For an evaporation temperature of-10 degrees C, the IHX effectiveness can be up to 0.5 for both R600a and R290. Finally, the maximum power consumption of the solar R290 refrigeration system was estimated around 4.08 kWh and 2.28 kWh at evaporation temperatures of-32 degrees C and-10 degrees C, respectively, which could be covered by a solar panel area of 3.76 m2 y 2.10 m2, respectively, while similar values were obtained for the solar R600a refrigeration system.
引用
收藏
页数:25
相关论文
共 46 条
  • [1] Amaris C., 2023, RECENT ADV ENERGY TE, P311, DOI [10.1007/978-981-19-3467-4_19, DOI 10.1007/978-981-19-3467-4_19]
  • [2] ASHRAE, 2019, SAF STAND REFR SYST
  • [3] Optimization of a multistage vapor-compression refrigeration system for various refrigerants
    Baakeem, Saleh S.
    Orfi, Jamel
    Alabdulkarem, Abdullah
    [J]. APPLIED THERMAL ENGINEERING, 2018, 136 : 84 - 96
  • [4] Energy and exergy analysis of vapor compression refrigeration system using pure hydrocarbon refrigerants
    Bayrakci, Hilmi Cenk
    Ozgur, Arif Emre
    [J]. INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2009, 33 (12) : 1070 - 1075
  • [5] Hourly simulation and performance of solar electric-vapor compression refrigeration system
    Bilgili, Mehmet
    [J]. SOLAR ENERGY, 2011, 85 (11) : 2720 - 2731
  • [6] Cabello R., 2022, INT J REFRIG, DOI [10.1016/J.IJREFRIG.2022, DOI 10.1016/J.IJREFRIG.2022]
  • [7] Screening of working fluids for the ejector refrigeration system
    Chen, Jianyong
    Hautun, Hans
    Palm, Bjorn
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2014, 47 : 1 - 14
  • [8] Theoretical investigation on the performance of an ejector enhanced refrigeration cycle using hydrocarbon mixture R290/R600a
    Chen, Qi
    Hwang, Yunho
    Yan, Gang
    Yu, Jianlin
    [J]. APPLIED THERMAL ENGINEERING, 2020, 164
  • [9] Experimental study of 12V and 24V photovoltaic DC refrigerator at different operating conditions
    Daffallah, K. O.
    [J]. PHYSICA B-CONDENSED MATTER, 2018, 545 : 237 - 244
  • [10] Experimental evaluation of photovoltaic DC refrigerator under different thermostat settings
    Daffallah, K. O.
    Benghanem, M.
    Alamri, S. N.
    Joraid, A. A.
    Al-Mashraqi, A. A.
    [J]. RENEWABLE ENERGY, 2017, 113 : 1150 - 1159