Dosimetric quality of HyperArc in boost radiotherapy for single glioblastoma: comparison with CyberKnife and manual VMAT

被引:3
|
作者
Pan, Mingyuan [1 ,2 ,3 ]
Xu, Wenqian [1 ,2 ,3 ]
Sun, Lei [1 ,2 ,3 ]
Wang, Chaozhuang [1 ,2 ,3 ]
Dong, Shengnan [1 ,2 ,3 ]
Guan, Yun [1 ,2 ,3 ]
Yang, Jun [4 ]
Wang, Enmin [1 ,2 ,3 ]
机构
[1] Fudan Univ, Huashan Hosp, CyberKnife Ctr, Dept Neurosurg, Shanghai, Peoples R China
[2] Fudan Univ, Neurosurg Inst, Shanghai, Peoples R China
[3] Shanghai Clin Med Ctr Neurosurg, Shanghai Key Lab Brain Funct & Restorat & Neural R, 12 Wulumuqi Rd M, Shanghai 200040, Peoples R China
[4] Foshan Chancheng Hosp, Radonc Dept, 3 Sanyou Rd, Foshan 528000, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
Stereotactic radiotherapy; Dosimetry; CyberKnife; HyperArc; Glioblastoma; RADIATION-THERAPY; STEREOTACTIC RADIOSURGERY;
D O I
10.1186/s13014-022-02150-y
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background Stereotactic radiotherapy (SRT) and hypo-fractionated radiotherapy are feasible treatment options for single glioblastoma multiforme when combined with conventional radiotherapy or delivered alone. HyperArc (HA), a novel linac-based method with 4 noncoplanar arcs, has been introduced into stereotactic radiosurgery (SRS) for single and multiple metastases. In this study, we compared the dosimetric quality of HyperArc with the well-established CyberKnife (CK) and conventional VMAT methods of SRT for a single, large target.Methods Sixteen patients treated in our center with their clinical CK plans were enrolled, and the linac-based plans were designed in silico. From the aspect of normal tissue protection and treatment efficacy, we compared the conformity index (CI), gradient index (GI), homogeneity index (HI), dose distribution in planning target volume, dose in the normal brain tissue, and mean dose of several organs at risk (OARs). All of the data were evaluated with nonparametric Kruskal?Wallis tests. We further investigated the relationship of the dose distribution with the tumor volume and its location.Results The results showed that with a higher CI (0.94 +/- 0.03) and lower GI (2.57 +/- 0.53), the HA plans generated a lower dose to the OARs and the normal tissue. Meanwhile, the CK plans achieved a higher HI (0.35 +/- 0.10) and generated a higher dose inside the tumor. Although manual VMAT showed slight improvement in dose quality and less monitoring units (2083 +/- 225), HA can save half of the delivery time of CK (37 minutes) on average.Conclusion HA plans have higher conformity and spare OARs with lower normal tissue irradiation, while CK plans achieve a higher mean dose in tumors. HA with 4 arcs is sufficient in dosimetric quality for a single tumor with great convenience in planning and treatment processes compared with conventional VMAT. The tumor size and location are factors to be considered when selecting treatment equipment.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Stereotactic Body Radiotherapy Boost with the CyberKnife for Locally Advanced Cervical Cancer: Dosimetric Analysis and Potential Clinical Benefits
    Gao, Jiaxiang
    Xu, Benhua
    Lin, Yibin
    Xu, Zhenhang
    Huang, Miaoyun
    Li, Xiaobo
    Wu, Xiaodong
    Chen, Yuangui
    CANCERS, 2022, 14 (20)
  • [22] A dosimetric comparison between CyberKnife and tomotherapy treatment plans for single brain metastasis
    Daniela Greto
    Stefania Pallotta
    Laura Masi
    Cinzia Talamonti
    Livia Marrazzo
    Raffaella Doro
    Calogero Saieva
    Silvia Scoccianti
    Isacco Desideri
    Lorenzo Livi
    La radiologia medica, 2017, 122 : 392 - 397
  • [23] Whole brain radiotherapy with adjuvant or concomitant boost in brain metastasis: dosimetric comparison between helical and volumetric IMRT technique
    Borghetti, Paolo
    Pedretti, Sara
    Spiazzi, Luigi
    Avitabile, Rossella
    Urpis, Mauro
    Foscarini, Federica
    Tesini, Giulia
    Trevisan, Francesca
    Ghirardelli, Paolo
    Pandini, Sara Angela
    Triggiani, Luca
    Magrini, Stefano Maria
    Buglione, Michela
    RADIATION ONCOLOGY, 2016, 11
  • [24] A comparison of several modulated radiotherapy techniques for head and neck cancer and dosimetric validation of VMAT
    Stieler, Florian
    Wolff, Dirk
    Schmid, Heike
    Welzel, Grit
    Wenz, Frederik
    Lohr, Frank
    RADIOTHERAPY AND ONCOLOGY, 2011, 101 (03) : 388 - 393
  • [25] Comparison of IMRT and VMAT radiotherapy planning for Graves' ophthalmopathy based on dosimetric parameters analysis
    Wang, S-C
    Wu, J.
    Xie, X-Q
    Liu, X-L
    Luo, Y.
    Wang, F.
    Li, Z-P
    Qu, B-L
    Kang, J-B
    Wu, D-B
    Li, W-M
    Wang, R-Y
    EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2020, 24 (07) : 3898 - 3906
  • [26] Dosimetric comparison of ZAP-X, Gamma Knife, and CyberKnife stereotactic radiosurgery for single brain metastasis
    Wang, Jinyuan
    Zheng, Qingzeng
    Wang, Yanping
    Wang, Chengcheng
    Xu, Shouping
    Ju, Zhongjian
    Pan, Longsheng
    Bai, Jingmin
    Liu, Yunmo
    Qu, Baolin
    Dai, Xiangkun
    BMC CANCER, 2024, 24 (01)
  • [27] Dosimetric comparison between cone/Iris-based and InCise MLC-based CyberKnife plans for single and multiple brain metastases
    Jang, Si Young
    Lalonde, Ron
    Ozhasoglu, Cihat
    Burton, Steven
    Heron, Dwight
    Huq, M. Saiful
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (05): : 184 - 199
  • [28] Dosimetric Comparison of Upfront Boosting With Stereotactic Radiosurgery Versus Intraoperative Radiotherapy for Glioblastoma
    Sarria, Gustavo R.
    Smalec, Zuzanna
    Muedder, Thomas
    Holz, Jasmin A.
    Scafa, Davide
    Koch, David
    Garbe, Stephan
    Schneider, Matthias
    Hamed, Motaz
    Vatter, Hartmut
    Herrlinger, Ulrich
    Giordano, Frank A.
    Schmeel, Leonard Christopher
    FRONTIERS IN ONCOLOGY, 2021, 11
  • [29] Dosimetric and radiobiological comparison of IMRT, VMAT, and helical tomotherapy planning techniques in hippocampal sparing whole brain radiotherapy with simultaneous integrated boost for multiple brain metastases
    Balasubramanian, S.
    Shobana, M. K.
    Anabalagan, D.
    Thanasekar, P.
    Joel, S.
    Chaudhary, Prekshi
    RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2024, 63 (01) : 47 - 57
  • [30] Stereotactic body radiotherapy using a hydrogel spacer for localized prostate cancer: A dosimetric comparison between tomotherapy with the newly-developed tumor-tracking system and cyberknife
    Manabe, Yoshihiko
    Hashimoto, Seiji
    Mukouyama, Hideki
    Shibamoto, Yuta
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (10): : 66 - 72