From 2D projections to the 3D rotation matrix: an attempt for finding a machine learning approach for the efficient evaluation of mechanical joining elements in X-ray computed tomography volume data

被引:1
|
作者
Schromm, T. M. [1 ]
Grosse, C. U. [1 ]
机构
[1] Tech Univ Munich, Chair Nondestruct Testing, Franz Langinger Str 10, D-81245 Munich, Germany
来源
SN APPLIED SCIENCES | 2023年 / 5卷 / 01期
关键词
Non-destructive testing; X-ray; Computed tomography; Mechanical joining; Rivets; Machine learning; Rotation; SELECTION;
D O I
10.1007/s42452-022-05220-8
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Destructive and predominantly manual procedures are commonly used in the automotive industry for the testing of mechanical joints, such as rivets or screws. Combining X-ray computed tomography (CT) and machine learning (ML) bears the potential of a non-destructive and largely automated methodology. Assuming the desired result is a comprehensible and documentable evaluation, three basic steps need to be automatized: First, a joint must be detected and identified as such in a CT scan of the joined parts. Second, the detected region containing the joint is rotated to a predefined orientation. Third, key measures in cross-sections from the newly oriented joint are dimensioned and documented. This work deals only with the second step, the rotation. On the one hand, we present a methodology for creating a well-curated data set for the contextual machine learning application. On the other, we evaluate its performance on the well-known ResNet50. More concretely, we investigate if it is possible for a deep convolutional neural network (CNN) to learn the respective rotation matrix from three volume projections that are perpendicular to each other. Two scenarios are investigated: In one scenario we assume that future data that is presented to the network has similar rivet demographics to historic data. We therefore do not employ hold-out sets for the network evaluation. In the other scenario we assume the opposite and therefore evaluating the networks performance with hold-out sets. We show that from a machine learning point of view, a CNN like ResNet50 is well able to learn this relationship with acceptable accuracy. In most cases the validation loss dropped below 0.1 after only a couple of epochs. In one particular case, we even reached both mean and median errors lower than 0.2 for approximately 80% of the entire test set of 1600 examples using our methodology. From an application point of view, however, these low test set errors should be treated with caution since small deviations from the intended rotation matrix can cause volume warping and translation. In another case, in which we used a hold-out set, only a fraction of the median errors were below 0.2.
引用
收藏
页数:16
相关论文
共 32 条
  • [21] Individual fibre segmentation from 3D X-ray computed tomography for characterising the fibre orientation in unidirectional composite materials
    Emerson, Monica J.
    Jespersen, Kristine M.
    Dahl, Anders B.
    Conradsen, Knut
    Mikkelsen, Lars P.
    COMPOSITES PART A-APPLIED SCIENCE AND MANUFACTURING, 2017, 97 : 83 - 92
  • [22] 3D VOLUMETRIC INTENSITY RECONSTURCTION FROM 2D X-RAY IMAGES USING PARTIAL LEAST SQUARES REGRESSION
    Zheng, Guoyan
    2013 IEEE 10TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2013, : 1268 - 1271
  • [23] 3D microstructure characterization of Cu-25Cr solid state sintered alloy using X-ray computed tomography and machine learning assisted segmentation
    Varoto, Lucas
    Blandin, Jean-Jacques
    Lhuissier, Pierre
    Roure, Sophie
    Papillon, Anthony
    Chosson, Melissa
    Martin, Guilhem
    MATERIALS CHARACTERIZATION, 2023, 203
  • [24] 3D computed tomography using a microfocus X-ray source: Analysis of artifact formation in the reconstructed images using simulated as well as experimental projection data
    Krimmel, S
    Stephan, J
    Baumann, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 542 (1-3) : 399 - 407
  • [25] Automatic 3D analysis of the ex-vivo porcine lumbar interbody fusion based on X-ray micro computed tomography data
    Laznovsky, Jakub
    Brinek, Adam
    Zikmund, Tomas
    Boudova, Marketa
    Vojtova, Lucy
    Dorazilova, Jana
    Trunec, Martin
    Stastny, Premysl
    Krticka, Milan
    Planka, Ladislav
    Ira, Daniel
    Faldyna, Martin
    Kaiser, Jozef
    COMPUTERS IN BIOLOGY AND MEDICINE, 2022, 145
  • [26] EVALUATION OF THE POSSIBILITY OF APPLYING SPATIAL 3D IMAGING USING X-RAY COMPUTED TOMOGRAPHY RECONSTRUCTION METHODS FOR QUANTITATIVE ANALYSIS OF MULTIPHASE MATERIALS
    Matysik, P.
    Chojnacki, M.
    Jozwiak, S.
    Czujko, T.
    Lipinski, S.
    ARCHIVES OF METALLURGY AND MATERIALS, 2015, 60 (04) : 2663 - 2669
  • [27] A proof of concept demonstration of the automated laser removal of rock from a fossil using 3D X-ray tomography data
    du Plessis, A.
    Steyn, J.
    Roberts, D. E.
    Botha, L. R.
    Berger, L. R.
    JOURNAL OF ARCHAEOLOGICAL SCIENCE, 2013, 40 (12) : 4607 - 4611
  • [28] Damage investigation and modeling of 3D woven ceramic matrix composites from X-ray tomography in-situ tensile tests
    Mazars, Vincent
    Caty, Olivier
    Couegnat, Guillaume
    Bouterf, Amine
    Roux, Stephane
    Denneulin, Sebastien
    Pailhes, Jerome
    Vignoles, Gerard L.
    ACTA MATERIALIA, 2017, 140 : 130 - 139
  • [29] X2V: 3D Organ Volume Reconstruction From a Planar X-Ray Image With Neural Implicit Methods
    Guven, Gokce
    Ates, Hasan F.
    Ugurdag, H. Fatih
    IEEE ACCESS, 2024, 12 : 50898 - 50910
  • [30] 3D microstructure characterization of 2D Cf-ZrB2-SiC ultra-high temperature ceramic matrix composites using X-ray microscopy
    Mishra, Adarsha Ranjan
    Singh, Vajinder
    Patel, Manish
    Mitra, Rahul