摘要
Destructive and predominantly manual procedures are commonly used in the automotive industry for the testing of mechanical joints, such as rivets or screws. Combining X-ray computed tomography (CT) and machine learning (ML) bears the potential of a non-destructive and largely automated methodology. Assuming the desired result is a comprehensible and documentable evaluation, three basic steps need to be automatized: First, a joint must be detected and identified as such in a CT scan of the joined parts. Second, the detected region containing the joint is rotated to a predefined orientation. Third, key measures in cross-sections from the newly oriented joint are dimensioned and documented. This work deals only with the second step, the rotation. On the one hand, we present a methodology for creating a well-curated data set for the contextual machine learning application. On the other, we evaluate its performance on the well-known ResNet50. More concretely, we investigate if it is possible for a deep convolutional neural network (CNN) to learn the respective rotation matrix from three volume projections that are perpendicular to each other. Two scenarios are investigated: In one scenario we assume that future data that is presented to the network has similar rivet demographics to historic data. We therefore do not employ hold-out sets for the network evaluation. In the other scenario we assume the opposite and therefore evaluating the networks performance with hold-out sets. We show that from a machine learning point of view, a CNN like ResNet50 is well able to learn this relationship with acceptable accuracy. In most cases the validation loss dropped below 0.1 after only a couple of epochs. In one particular case, we even reached both mean and median errors lower than 0.2 for approximately 80% of the entire test set of 1600 examples using our methodology. From an application point of view, however, these low test set errors should be treated with caution since small deviations from the intended rotation matrix can cause volume warping and translation. In another case, in which we used a hold-out set, only a fraction of the median errors were below 0.2.
引用
收藏
页数:16
相关论文
共 32 条
  • [1] From 2D projections to the 3D rotation matrix: an attempt for finding a machine learning approach for the efficient evaluation of mechanical joining elements in X-ray computed tomography volume data
    T. M. Schromm
    C. U. Grosse
    SN Applied Sciences, 2023, 5
  • [2] 2D/3D Microanalysis by Energy Dispersive X-ray Absorption Spectroscopy Tomography
    Sanchez, Dario Ferreira
    Simionovici, Alexandre S.
    Lemelle, Laurence
    Cuartero, Vera
    Mathon, Olivier
    Pascarelli, Sakura
    Bonnin, Anne
    Shapiro, Russell
    Konhauser, Kurt
    Grolimund, Daniel
    Bleuet, Pierre
    SCIENTIFIC REPORTS, 2017, 7
  • [3] EOS 2D/3D X-ray imaging system: a systematic review and economic evaluation
    McKenna, C.
    Wade, R.
    Faria, R.
    Yang, H.
    Stirk, L.
    Gummerson, N.
    Sculpher, M.
    Woolacott, N.
    HEALTH TECHNOLOGY ASSESSMENT, 2012, 16 (14) : 1 - +
  • [4] Synthesising 2D Video from 3D Motion Data for Machine Learning Applications
    Mundt, Marion
    Oberlack, Henrike
    Goldacre, Molly
    Powles, Julia
    Funken, Johannes
    Morris, Corey
    Potthast, Wolfgang
    Alderson, Jacqueline
    SENSORS, 2022, 22 (17)
  • [5] Evaluation of a breast software model for 2D and 3D X-ray imaging studies of the breast
    Baneva, Yanka
    Bliznakova, Kristina
    Cockmartin, Lesley
    Marinov, Stoyko
    Buliev, Ivan
    Mettivier, Giovanni
    Bosmans, Hilde
    Russo, Paolo
    Marshall, Nicholas
    Bliznakov, Zhivko
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 41 : 78 - 86
  • [6] A novel technology for 3D knee prosthesis planning and treatment evaluation using 2D X-ray radiographs: a clinical evaluation
    Zheng, Guoyan
    Hommel, Hagen
    Akcoltekin, Alper
    Thelen, Benedikt
    Stifter, Jan
    Peersman, Geert
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2018, 13 (08) : 1151 - 1158
  • [7] Machine learning for predicting properties of porous media from 2d X-ray images
    Alqahtani, Naif
    Alzubaidi, Fatimah
    Armstrong, Ryan T.
    Swietojanski, Pawel
    Mostaghimi, Peyman
    JOURNAL OF PETROLEUM SCIENCE AND ENGINEERING, 2020, 184
  • [8] From 2D STXM to 3D Imaging: Soft X-ray Laminography of Thin Specimens
    Witte, Katharina
    Spaeth, Andreas
    Finizio, Simone
    Donnelly, Claire
    Watts, Benjamin
    Sarafimov, Blagoj
    Odstrcil, Michal
    Guizar-Sicairos, Manuel
    Holler, Mirko
    Fink, Rainer H.
    Raabe, Jorg
    NANO LETTERS, 2020, 20 (02) : 1305 - 1314
  • [9] Transgraph: interactive intensity-based 2D/3D registration of X-ray and CT data
    LaRose, D
    Bayouth, J
    Kanade, T
    MEDICAL IMAGING 2000: IMAGE PROCESSING, PTS 1 AND 2, 2000, 3979 : 385 - 396
  • [10] Novel 2D and 3D imaging of internal aerated structure of ultrasonically treated foams and cakes using X-ray tomography and X-ray microtomography
    Tan, M. C.
    Chin, N. L.
    Yusof, Y. A.
    Abdullah, J.
    JOURNAL OF FOOD ENGINEERING, 2016, 183 : 9 - 15