The Effect of Conducted Emissions of Grid-Tied Three-Phase Adjustable Drives

被引:0
|
作者
Genc, Secil [1 ]
Muneeswaran, Venkatkumar [2 ]
Thomas, David [2 ]
Greedy, Steve [2 ]
Gundogdu, Burcu [3 ]
Sarma, Nur [4 ,5 ]
Ozgonenel, Okan [1 ]
机构
[1] Ondokuz Mayis Univ, Elect Elect Engn Dept, Samsun, Turkiye
[2] Univ Nottingham, Elect Elect Engn Dept, Nottingham, England
[3] Hakkari Univ Colemerik, VHS, Comp Technol, Hakkari, Turkiye
[4] Duzce Univ, Elect Elect Engn Dept, Duzce, Turkiye
[5] Univ Durham, Dept Engn, Durham, England
关键词
Conducted emission (CE); Electromagnetic compatibility (EMC); Electromagnetic interference (EMI); Adjustable motor drive inverters; EMI FILTER;
D O I
10.1016/j.jestch.2023.101505
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Electromagnetic Interference (EMI) is generated and mitigated in power converters. EMI problems are related to high-speed power converters. This article focuses on conducted electromagnetic interference in adjustable-speed drive (ASD) systems. The electromagnetic compatibility of three-phase/level grid-connected drive inverters is investigated. The test setup is built per the CISPR16-1-2 standard, and the interferences produced from the inverter to the grid are measured. The main dependencies of conducted emissions of a power inverter, changes in the length/shape of main cables, and motor speed have been investigated under load and no load conditions. Factors affecting EMI performance and filter design issues will be addressed. A statistical approach to quantifying the frequency domain impact of conducted emission noise created on the three-phase system by operating various emission sources. Fast Fourier Transform (FFT) was applied for time-frequency domain conversion, and to evaluate with a statistical approach Minitab software was used. Then, a filter design is created to prevent these interferences from being conducted to the grid. Also, the noise attenuation of the EMI filter has been validated in the simulation. Briefly, this study fills in the blanks of uncertainties involved in measuring three-phase emissions, which helps the engineers at the design stage of three-phase converters.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Dynamic Aggregation of Grid-Tied Three-Phase Inverters
    Purba, Victor
    Johnson, Brian B.
    Jafarpour, Saber
    Bullo, Francesco
    Dhople, Sairaj V.
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2020, 35 (02) : 1520 - 1530
  • [2] Classification of Three-Phase Grid-Tied Microinverters in Photovoltaic Applications
    Shawky, Ahmed
    Ahmed, Mahrous
    Orabi, Mohamed
    El Aroudi, Abdelali
    ENERGIES, 2020, 13 (11)
  • [3] Modelling and analysis of three-phase grid-tied photovoltaic systems
    Abraham Dandoussou
    Pierre Kenfack
    Journal of Electrical Systems and Information Technology, 10 (1)
  • [4] Robust Design of Control Structure for Three-Phase Grid-Tied Inverters
    Kraemer, Rodrigo A. S.
    Carati, Emerson G.
    da Costa, Jean P.
    Cardoso, Rafael
    Stein, Carlos M. O.
    2018 13TH IEEE INTERNATIONAL CONFERENCE ON INDUSTRY APPLICATIONS (INDUSCON), 2018, : 636 - 643
  • [5] FRT Capability of Three-phase Grid-tied Converter with Minimized Inductor
    Nagai, Satoshi
    Itoh, Jun-ichi
    THIRTY-FOURTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC 2019), 2019, : 1070 - 1077
  • [6] Network-cognizant Model Reduction of Grid-tied Three-phase Inverters
    Purba, Victor
    Dhople, Sairaj V.
    Jafarpour, Saber
    Bullo, Francesco
    Johnson, Brian B.
    2017 55TH ANNUAL ALLERTON CONFERENCE ON COMMUNICATION, CONTROL, AND COMPUTING (ALLERTON), 2017, : 157 - 164
  • [7] Three-Phase Grid-Tied Photovoltaic Inverter With Reactive Power Compensation Capability
    Arellanes, A.
    Rodriguez, E.
    Orosco, R.
    Perez, J.
    Beristain, J.
    2017 IEEE INTERNATIONAL AUTUMN MEETING ON POWER, ELECTRONICS AND COMPUTING (ROPEC), 2017,
  • [8] Conducted Emission Suppression Using an EMI Filter for Grid-Tied Three-Phase/Level T-Type Solar Inverter
    Hizarci, Halime
    Pekperlak, Umit
    Arifoglu, Ugur
    IEEE ACCESS, 2021, 9 : 67417 - 67431
  • [9] Impact of the Phase-Angle Detection Inaccuracies on the Performance of a Three-Phase Grid-Tied System
    Bacon, Vinicius D.
    da Silva, Sergio A. O.
    de Souza, Vinicius
    Campanhol, Leonardo B. G.
    2019 21ST EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE '19 ECCE EUROPE), 2019,
  • [10] Conducted EMI in Grid-tied PV System
    Hamza, Djilali
    Jain, Praveen
    32ND INTERNATIONAL TELECOMMUNICATIONS ENERGY CONFERENCE (INTELEC), 2010,