A flexible optimization study on air-cooled battery thermal management system by considering of system volume and cooling performance

被引:6
|
作者
Lu, Hao [1 ,2 ]
Tang, Xiaole [1 ]
机构
[1] Xinjiang Univ, Sch Elect Engn, Lab Clean Energy, Urumqi 830047, Peoples R China
[2] Xinjiang Univ, Sch Future Technol, Urumqi 830047, Peoples R China
基金
中国国家自然科学基金;
关键词
Battery thermal management; Air cooling; Multi-objective optimization; Shortcut computation model; LITHIUM-ION BATTERY; DESIGN OPTIMIZATION; FLOW CONFIGURATION; GENETIC ALGORITHM; PACK;
D O I
10.1016/j.est.2023.108527
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
When the battery temperature exceeds the normal range, the battery efficiency performance, and life will be significantly reduced, and the battery may even explode. Therefore, an optimal battery thermal management system is required to dissipate heat efficiently. The existing research focuses on the structural design to reduce the maximum temperature of the system. However, the volume of the cooling system is also important for electric vehicle design, which has received little attention. In this study, a new flexible optimization strategy for a battery thermal management system is proposed, which is a hybrid of system volume and cooling performance and can determine the appropriate optimized structure according to the engineering applications. The proposed method belongs to four steps: optimization system design, establishment of shortcut computation codes, multiobjective optimization and comprehensive fuzzy decision making. The numerical simulation based on computational fluid dynamics (CFD) is used to verify the cooling performance of the optimized system. Compared with the three existing designs of battery thermal management system from previous literatures, the volume is reduced by a maximum of 13.01 %. In the process of stable heat generation, the maximum temperature difference decreased by 65.79 %, 40.65 %, and 63.69 %, and the temperature uniformity increased by 65.87 %, 34.93 %, and 60.80 %, respectively. In the unsteady heat generation of the battery pack, at the discharge rate of 5C, the maximum temperature difference decreases by 2.28 K, and the maximum temperature difference and temperature uniformity decrease by 57.11 % and 49.15 %, respectively.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Cooling performance optimization of air-cooled battery thermal management system
    Wang, Meiwei
    Teng, Shiyang
    Xi, Huan
    Li, Yuquan
    APPLIED THERMAL ENGINEERING, 2021, 195
  • [2] Cooling Performance Optimization of Air-Cooled Battery Thermal Management System with L-Type Flow
    Zhang, Xinyue
    Fan, Xueliang
    Deng, Yelin
    ENERGY TECHNOLOGY, 2023, 11 (09)
  • [3] Structure optimization of parallel air-cooled battery thermal management system
    Chen, Kai
    Wang, Shuangfeng
    Song, Mengxuan
    Chen, Lin
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2017, 111 : 943 - 952
  • [4] Structure optimization of air-cooled battery thermal management system based on neural network
    Chen, Jiahui
    Xuan, Dongji
    Chen, Cong
    Chen, Jianlong
    Shen, Yunde
    IONICS, 2023, 29 (07) : 2773 - 2782
  • [5] Design of Parallel Air-Cooled Battery Thermal Management System through Numerical Study
    Chen, Kai
    Li, Zeyu
    Chen, Yiming
    Long, Shuming
    Hou, Junsheng
    Song, Mengxuan
    Wang, Shuangfeng
    ENERGIES, 2017, 10 (10):
  • [6] Numerical study on air-cooled battery thermal management system considering the sheer altitude effect
    Li, Yonghao
    Kong, Benben
    Qiu, Chenghui
    Li, Yu
    Jiang, Yanlong
    APPLIED THERMAL ENGINEERING, 2025, 258
  • [7] Structure optimization of air-cooled battery thermal management system based on neural network
    Chen Jiahui
    Xuan Dongji
    Chen Cong
    Chen Jianlong
    Shen Yunde
    Ionics, 2023, 29 : 2773 - 2782
  • [8] Configuration optimization of battery pack in parallel air-cooled battery thermal management system using an optimization strategy
    Chen, Kai
    Wang, Shuangfeng
    Song, Mengxuan
    Chen, Lin
    APPLIED THERMAL ENGINEERING, 2017, 123 : 177 - 186
  • [9] Numerical Study on Performance Enhancement of the Air-Cooled Battery Thermal Management System by Adding Parallel Plates
    Wang, Meiwei
    Hung, Tzu-Chen
    Xi, Huan
    ENERGIES, 2021, 14 (11)
  • [10] Construction of effective symmetrical air-cooled system for battery thermal management
    Chen, Kai
    Chen, Yiming
    She, Yiqi
    Song, Mengxuan
    Wang, Shuangfeng
    Chen, Lin
    APPLIED THERMAL ENGINEERING, 2020, 166