Life cycle costing of AnMBR technology for urban wastewater treatment: A case study based on a demo-scale AnMBR system

被引:8
作者
Jimenez-Benitez, A. [1 ]
Ruiz-Martinez, A. [1 ]
Ferrer, J. [2 ]
Ribes, J. [1 ]
Rogalla, F. [3 ]
Robles, A. [1 ]
机构
[1] Univ Valencia, Dept Engn Quim, Unidad Mixta UV UPV, CALAGUA, Ave Univ S-N, Valencia 46100, Spain
[2] Univ Politecn Valencia, Inst Univ Invest Engn Aigua & Med Ambient, Unidad Mixta UV UPV, CALAGUA,IIAMA, Cami Vera S-N, Valencia 46022, Spain
[3] FCC Aqualia SA, Ave Camino Santiago 40, Madrid 28050, Spain
来源
JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING | 2023年 / 11卷 / 03期
关键词
Municipal wastewater treatment; Semi-industrial scale system; Prototype AnMBR; Economic assessment; Life cycle assessment; Sewage; ANAEROBIC MEMBRANE BIOREACTOR; TREATMENT PLANTS; SUSTAINABILITY ASSESSMENT; ENERGY-CONSUMPTION; FOOD WASTE; EFFICIENCY; RECOVERY; STRATEGIES; WWTP; MBR;
D O I
10.1016/j.jece.2023.110267
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study aims at assessing the economic performance of a projected full-scale anaerobic membrane bioreactor (AnMBR) for urban wastewater (UWW) treatment at ambient temperature. To this aim, data from an AnMBR demonstration plant (industrial prototype, TRL 6) was used, which was operated for 3 years treating real UWW, allowing gathering a robust set of information for scaling-up to full scale. The obtained results revealed that reactor mixing (0.056-0.124 kWh center dot kgCOD(rem)(-1); 34-57%), and membrane scouring (0.048-0.120 kWh center dot kgCOD(rem)(-1); 22-48%) were the main contributors to the total energy demand; while net energy productions between 0.210 and 0.645 kWh center dot kgCOD(rem)(-1) were achieved. Capital expenditure was highly influenced by UF membranes ((sic)0.029-0.073 kgCOD(rem)(-1); 31-49%), combined heat and power technology for energy recovery ((sic)0.012-0.023 kgCOD(rem)(-1); 8-24%), and reactor construction ((sic)0.07-0.014 kgCOD(rem)(-1); 8-13%); while the main contributors to operating expenditure were energy requirements ((sic)0.042-0.069 kgCOD(rem)(-1); 41-46%), membrane replacement ((sic)0.011-0.028 kgCOD(rem)(-1); 9-17%), and discharge fee ((sic)0.010-0.020 kgCOD(rem)(-1); 9-12%). Total annualized costs showed high variability, between (sic) -0.003 and 0.188 kgCOD(rem)(-1). Results presents AnMBR as a competitive technology for UWW treatment compared to conventional aerobic technologies (e.g., CAS). Membrane fouling control; hydraulic retention time; biogas requirements for reactor mixing and membrane stirring; and energy recovery efficiency were identified as key parameters for improving economic sustainability of AnMBR technology.
引用
收藏
页数:13
相关论文
共 48 条
[21]  
Judd S., 2006, The MBR Book, DOI [10.1016/B978-1-85617-481-7.X5000-4, DOI 10.1016/B978-1-85617-481-7.X5000-4]
[22]   Membrane technology costs and me [J].
Judd, S. J. .
WATER RESEARCH, 2017, 122 :1-9
[23]  
Kloepffer W, 2008, INT J LIFE CYCLE ASS, V13, P89, DOI 10.1065/lca2008.02.376
[24]   Monitoring and diagnosis of energy consumption in wastewater treatment plants. A state of the art and proposals for improvement [J].
Longo, Stefano ;
d'Antoni, Benedetto Mirko ;
Bongards, Michael ;
Chaparro, Antonio ;
Cronrath, Andreas ;
Fatone, Francesco ;
Lema, Juan M. ;
Mauricio-Iglesias, Miguel ;
Soares, Ana ;
Hospido, Almudena .
APPLIED ENERGY, 2016, 179 :1251-1268
[25]   A new strategy to maximize organic matter valorization in municipalities: Combination of urban wastewater with kitchen food waste and its treatment with AnMBR technology [J].
Monino, P. ;
Aguado, D. ;
Barat, R. ;
Jimenez, E. ;
Gimenez, J. B. ;
Seco, A. ;
Ferrer, J. .
WASTE MANAGEMENT, 2017, 62 :274-289
[26]   Evolution of the activated sludge process: the first 50 years [J].
Orhon, Derin .
JOURNAL OF CHEMICAL TECHNOLOGY AND BIOTECHNOLOGY, 2015, 90 (04) :608-640
[27]   A review of anaerobic membrane bioreactors for municipal wastewater treatment: Integration options, limitations and expectations [J].
Ozgun, Hale ;
Dereli, Recep Kaan ;
Ersahin, Mustafa Evren ;
Kinaci, Cumali ;
Spanjers, Henri ;
van Lier, Jules B. .
SEPARATION AND PURIFICATION TECHNOLOGY, 2013, 118 :89-104
[28]   A plant-wide energy model for wastewater treatment plants: application to anaerobic membrane bioreactor technology [J].
Pretel, R. ;
Robles, A. ;
Ruano, M. V. ;
Seco, A. ;
Ferrer, J. .
ENVIRONMENTAL TECHNOLOGY, 2016, 37 (18) :2298-2315
[29]   Economic and environmental sustainability of submerged anaerobic MBR-based (AnMBR-based) technology as compared to aerobic-based technologies for moderate-/high-loaded urban wastewater treatment [J].
Pretel, R. ;
Robles, A. ;
Ruano, M. V. ;
Seco, A. ;
Ferrer, J. .
JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2016, 166 :45-54
[30]   Designing an AnMBR-based WWTP for energy recovery from urban wastewater: The role of primary settling and anaerobic digestion [J].
Pretel, R. ;
Duran, F. ;
Robles, A. ;
Ruano, M. V. ;
Ribes, J. ;
Serralta, J. ;
Ferrer, J. .
SEPARATION AND PURIFICATION TECHNOLOGY, 2015, 156 :132-139