G4XRTube: A Geant4-based Monte Carlo application for X-ray tube simulation

被引:3
作者
Idrissi, Abdelghani [1 ]
Dourki, Ibrahym [1 ,2 ]
El Bardouni, T. [1 ]
El Hajjaji, O. [1 ]
El-Bouzaidi, Mohamed Drissi [1 ]
Mira, Mohamed [1 ]
机构
[1] Abdelmalek Essaadi Univ, Radiat & Nucl Syst Grp, Tetouan, Morocco
[2] European XFEL GmbH, Holzkoppel 4, D-22869 Schenefeld, Germany
关键词
G4XRTube; X-ray tube simulation; X-ray spectrum; Geant4; Heel effect; SPECTRA; VALIDATION; ELECTRONS; TOOLKIT; ENERGY;
D O I
10.1016/j.radphyschem.2023.110864
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
This paper focuses mainly on the generation of X-rays in the X-ray tubes and their utilization in imaging applications. In this work, the Geant4 Monte Carlo simulation toolkit was used to develop an application for simulating the production of X-rays in X-ray tubes. This Geant4-based Monte Carlo application generates X-ray spectra depending on anode angle, tube voltage, filter and anode material. In addition to X-ray spectra, G4XRTube can be used, for instance, for the prediction of half-value layer (HVL) and investigation of anode heel effect. The utilization of G4XRTube can also be extended to include other fields such as radiation protection, shielding, dosimetry and investigation of the performance of X-ray tubes and detectors. The results obtained in this work with G4XRTube were validated against existing data in the literature. Specifically, we compared our results with experimental literature data and TASMICS, SpekCalc, and SpekPy codes. The comparison shows a good agreement between G4XRTube results and other data.
引用
收藏
页数:6
相关论文
共 25 条
  • [11] Fewell T., 1981, HDB COMPUTED TOMOGRA
  • [12] Fewell T., 1978, HDB MAMMOGRAPHIC XRA
  • [13] INITIAL MCNP6 RELEASE OVERVIEW
    Goorley, T.
    James, M.
    Booth, T.
    Brown, F.
    Bull, J.
    Cox, L. J.
    Durkee, J.
    Elson, J.
    Fensin, M.
    Forster, R. A.
    Hendricks, J.
    Hughes, H. G.
    Johns, R.
    Kiedrowski, B.
    Martz, R.
    Mashnik, S.
    McKinney, G.
    Pelowitz, D.
    Prael, R.
    Sweezy, J.
    Waters, L.
    Wilcox, T.
    Zukaitis, T.
    [J]. NUCLEAR TECHNOLOGY, 2012, 180 (03) : 298 - 315
  • [14] Tungsten anode spectral model using interpolating cubic splines: Unfiltered x-ray spectra from 20 kV to 640 kV
    Hernandez, Andrew M.
    Boone, John M.
    [J]. MEDICAL PHYSICS, 2014, 41 (04)
  • [15] Using Geant4 Monte Carlo toolkit to evaluate a low power X-ray tube generator configuration
    Hoff, G.
    Streck, E. E.
    Lai, A.
    Fanti, V
    Golosio, B.
    Nascimento, C. D.
    Souza, E. G.
    [J]. APPLIED RADIATION AND ISOTOPES, 2021, 168
  • [16] Accurate condensed history Monte Carlo simulation of electron transport. I. EGSnrc, the new EGS4 version
    Kawrakow, I
    [J]. MEDICAL PHYSICS, 2000, 27 (03) : 485 - 498
  • [17] On the theory of X-ray absorption and of the continuous X- ray spectrum
    Kramers, HA
    [J]. PHILOSOPHICAL MAGAZINE, 1923, 46 (275): : 836 - 871
  • [18] Performance of different theories for the angular distribution of bremsstrahlung produced by keV electrons incident upon a target
    Omar, Artur
    Andreo, Pedro
    Poludniowski, Gavin
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2018, 148 : 73 - 85
  • [19] Mathematical estimation of half-value layer thicknesses
    Omoumi, Farid H.
    Wu, Xizeng
    Ghani, Muhammad U.
    Wong, Molly D.
    Li, Yuhua
    Liu, Hong
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (10): : 320 - 328
  • [20] SpekCalc: a program to calculate photon spectra from tungsten anode x-ray tubes
    Poludniowski, G.
    Landry, G.
    DeBlois, F.
    Evans, P. M.
    Verhaegen, F.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (19) : N433 - N438