Impedimetric Biosensor Coated with Zinc Oxide Nanorods Synthesized by a Modification of the Hydrothermal Method for Antibody Detection

被引:2
作者
Sitkov, Nikita [1 ,2 ]
Ryabko, Andrey [3 ]
Kolobov, Alexey [2 ,4 ]
Maximov, Alexsandr [1 ]
Moshnikov, Vyacheslav [1 ]
Pshenichnyuk, Stanislav [5 ]
Komolov, Alexei [6 ]
Aleshin, Andrey [3 ]
Zimina, Tatiana [1 ,2 ]
机构
[1] St Petersburg Electrotech Univ LETI, Dept Micro & Nanoelect, St Petersburg 197022, Russia
[2] St Petersburg Electrotech Univ LETI, Ctr Digital Telecommun Technol, St Petersburg 197022, Russia
[3] Ioffe Inst, Lab Nonequilibrium Proc Semicond, 26 Politekhn Skaya, St Petersburg 194021, Russia
[4] Inst Human Hyg Occupat Pathol & Ecol, Lab Peptide Chem, St Petersburg 188663, Russia
[5] Russian Acad Sci, Inst Mol & Crystal Phys, Ufa Fed Res Ctr, Lab Phys Atom Collis, Prospe?t Oktyabrya 151, Ufa 450075, Russia
[6] St Petersburg State Univ, Solid State Elect Dept, St Petersburg 199034, Russia
基金
俄罗斯科学基金会;
关键词
impedimetric biosensor; zinc oxide; express detection; nanorods; antibodies; label-free detection; hydrothermal synthesis; ZNO NANORODS; ULTRASENSITIVE DETECTION; BIOMARKERS;
D O I
10.3390/chemosensors11010066
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Impedimetric biosensors are used for detecting a wide range of analytes. The detection principle is a perspective for the development of new types of analytical devices for biomolecular diagnosis of diseases. Of particular interest are biosensors with very high sensitivities, capable of detecting trace amounts of biomarkers or drugs in biological fluids. Impedimetric biosensors possess a potential for increased sensitivity, since their electrodes can be modified with nanostructured materials, in particular zinc oxide. In this work, a miniature biosensor with an array of zinc oxide nanorods synthesized by the hydrothermal method has been created. Protein A was immobilized on the resulting structure, which was previously tested for binding to omalizumab by capillary electrophoresis. Using impedance spectroscopy, it was possible to detect the binding of omalizumab at concentrations down to 5 pg/mL. The resulting structures are suitable for creating reusable biosensor systems, since ZnO-coated electrodes are easily cleaned by photocatalytic decomposition of the bound molecules. The biosensor is promising for use in Point-of-Care systems designed for fast, multimodal detection of molecular markers of a wide range of diseases.
引用
收藏
页数:17
相关论文
共 70 条
[31]   ZnO nanowires with high aspect ratios grown by metalorganic chemical vapor deposition using gold nanoparticles [J].
Kim, SW ;
Fujita, S ;
Fujita, S .
APPLIED PHYSICS LETTERS, 2005, 86 (15) :1-3
[32]   Strategies to simplify operation procedures for applying labeled antibody-based immunosensors to point-of-care testing [J].
Kimura, Hayato ;
Asano, Ryutaro .
ANALYTICAL BIOCHEMISTRY, 2022, 654
[33]   Silicon Nanowire-Based Room-Temperature Multi-environment Ammonia Detection [J].
Kondratev, Valeriy M. ;
Morozov, Ivan A. ;
Vyacheslavova, Ekaterina A. ;
Kirilenko, Demid A. ;
Kuznetsov, Alexey ;
Kadinskaya, Svetlana A. ;
Nalimova, Svetlana S. ;
Moshnikov, Vyacheslav A. ;
Gudovskikh, Alexander S. ;
Bolshakov, Alexey D. .
ACS APPLIED NANO MATERIALS, 2022, :9940-9949
[34]   Novel insight on the local surface properties of ZnO nanowires [J].
Kwoka, Monika ;
Kulis-Kapuscinska, Anna ;
Zappa, Dario ;
Comini, Elisabetta ;
Szuber, Jacek .
NANOTECHNOLOGY, 2020, 31 (46)
[35]   Electrochemical synthesis of orientation-ordered ZnO nanorod bundles [J].
Li, Gao-Ren ;
Dawa, Ci-Ren ;
Bu, Qiong ;
Zhen, Fu-lin ;
Lu, Xi-Hong ;
Ke, Zhi-Hai ;
Hong, Hai-En ;
Yao, Chen-Zhong ;
Liu, Peng ;
Tong, Ye-Xiang .
ELECTROCHEMISTRY COMMUNICATIONS, 2007, 9 (05) :863-868
[36]   Electrochemical Impedance Spectroscopy (EIS): Principles, Construction, and Biosensing Applications [J].
Magar, Hend S. ;
Hassan, Rabeay Y. A. ;
Mulchandani, Ashok .
SENSORS, 2021, 21 (19)
[37]   Diagnosis, classification, and therapeutic interventions for sinopulmonary Aspergillosis [J].
McCarthy, Matthew William ;
Aguilar-Zapata, Daniel ;
Petraitis, Vidmantas ;
Walsh, Thomas J. .
EXPERT REVIEW OF RESPIRATORY MEDICINE, 2017, 11 (03) :229-238
[38]   Physical Interpretations of Nyquist Plots for EDLC Electrodes and Devices [J].
Mei, Bing-Ang ;
Munteshari, Obaidallah ;
Lau, Jonathan ;
Dunn, Bruce ;
Pilon, Laurent .
JOURNAL OF PHYSICAL CHEMISTRY C, 2018, 122 (01) :194-206
[39]   Recent advances and challenges in electrochemical biosensors for emerging and re-emerging infectious diseases [J].
Menon, Shalini ;
Mathew, Manna Rachel ;
Sam, Sonia ;
Keerthi, K. ;
Kumar, K. Girish .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2020, 878
[40]   A wearable microfluidics-integrated impedimetric immunosensor based on Ti3C2Tx MXene incorporated laser-burned graphene for noninvasive sweat cortisol detection [J].
Nah, Joong San ;
Barman, Sharat Chandra ;
Abu Zahed, Md ;
Sharifuzzaman, Md. ;
Yoon, Hyosang ;
Park, Chani ;
Yoon, Sanghyuk ;
Zhang, Shipeng ;
Park, Jae Yeong .
SENSORS AND ACTUATORS B-CHEMICAL, 2021, 329