Impact of implantation technique on conduction disturbances for TAVR with the self-expanding portico/navitor valve

被引:10
作者
Wang, Xi [1 ,2 ]
Wong, Ivan [2 ]
Bajoras, Vilhelmas [2 ]
Vanhaverbeke, Maarten [2 ]
Nuyens, Philippe [2 ]
Bieliauskas, Gintautas [2 ]
Jorgensen, Troels Hojsgaard [2 ]
Chen, Mao [1 ]
De Backer, Ole [2 ]
Sondergaard, Lars [2 ,3 ]
机构
[1] Sichuan Univ, West China Hosp, Dept Cardiol, Chengdu, Peoples R China
[2] Copenhagen Univ Hosp, Heart Ctr, Rigshosp, Copenhagen, Denmark
[3] Univ Copenhagen, Heart Ctr, Rigshosp, Blegdamsvej 9, DK-2100 Copenhagen, Denmark
关键词
conduction disturbance; fluoroscopic view; implantation technique; pacemaker implantation; transcatheter aortic valve replacement; TRANSCATHETER AORTIC-VALVE; EVOLUT-PRO; REPLACEMENT; MANAGEMENT; PROJECTION;
D O I
10.1002/ccd.30517
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Use of a right-left (R-L) cusp overlap view for transcatheter aortic valve replacement (TAVR) with self-expanding valves has recently been proposed aiming to reduce permanent pacemaker implantation (PPMI). An objective, data-driven explanation for this observation is missing. Aims: To assess the impact of different implantation techniques on the risk of PPMI following TAVR with the Portico/Navitor (TM) transcatheter heart valve (THV; Abbott). Methods: A TAVR-population treated with Portico/Navitor (TM) had the THV implanted in a right versus left anterior oblique (RAO/LAO) fluoroscopic view with no parallax in the delivery system. The impact of these different implantation views on the spatial relationship between THV and native aortic annulus and the risk of conduction disturbances and PPMI after TAVR was studied. Results: A total of 366 matched TAVR patients were studied: 183 in the RAO group and 183 in the LAO group. The degree of aortic annulus plane tilt was significantly smaller in the RAO versus LAO group (median: 0 degrees vs. 23 degrees, p < 0.001), with no plane tilt in 105 out of 183 cases (57.3%) in the RAO group. At 30 days after TAVR, the overall PPMI and guideline-directed PPMI rates were 12.6% versus 18.0% (p = 0.15) and 8.2% versus 15.3% (p = 0.04) in the RAO versus LAO group, respectively. Conclusions: Use of a R-L cusp overlap (RAO-caudal) view for implantation of the Portico/Navitor (TM) valve results in less tilt of the native aortic annulus plane and a clear trend toward a lower 30-day PPMI rate as compared to TAVR using the conventional LAO implantation view.
引用
收藏
页码:431 / 441
页数:11
相关论文
共 28 条
[1]   Transcatheter Aortic-Valve Replacement with a Self-Expanding Prosthesis [J].
Adams, David H. ;
Popma, Jeffrey J. ;
Reardon, Michael J. ;
Yakubov, Steven J. ;
Coselli, Joseph S. ;
Deeb, G. Michael ;
Gleason, Thomas G. ;
Buchbinder, Maurice ;
Hermiller, James, Jr. ;
Kleiman, Neal S. ;
Chetcuti, Stan ;
Heiser, John ;
Merhi, William ;
Zorn, George ;
Tadros, Peter ;
Robinson, Newell ;
Petrossian, George ;
Hughes, G. Chad ;
Harrison, J. Kevin ;
Conte, John ;
Maini, Brijeshwar ;
Mumtaz, Mubashir ;
Chenoweth, Sharla ;
Oh, Jae K. .
NEW ENGLAND JOURNAL OF MEDICINE, 2014, 370 (19) :1790-1798
[2]   Double S-Curve Versus Cusp-Overlap Technique Defining the Optimal Fluoroscopic Projection for TAVR With a Self-Expanding Device [J].
Ben-Shoshan, Jeremy ;
Alosaimi, Hind ;
Lauzier, Pascal Theriault ;
Pighi, Michele ;
Talmor-Barkan, Yeela ;
Overtchouk, Pavel ;
Martucci, Giuseppe ;
Spaziano, Marco ;
Finkelstein, Ariel ;
Gada, Hemal ;
Piazza, Nicolo .
JACC-CARDIOVASCULAR INTERVENTIONS, 2021, 14 (02) :185-194
[3]   Patient-Specific Implantation Technique to Obtain Neo-Commissural Alignment With Self-Expanding Transcatheter Aortic Valves [J].
Bieliauskas, Gintautas ;
Wong, Ivan ;
Bajoras, Vilhelmas ;
Wang, Xi ;
Kofoed, Klaus Fuglsang ;
De Backer, Ole ;
Sondergaard, Lars .
JACC-CARDIOVASCULAR INTERVENTIONS, 2021, 14 (19) :2097-2108
[4]   Transcatheter aortic valve replacement (TAVR): expanding indications to low-risk patients [J].
Cubero-Gallego, Hector ;
Dam, Christian ;
Meca, Juan ;
Avanzas, Pablo .
ANNALS OF TRANSLATIONAL MEDICINE, 2020, 8 (15)
[5]   The Latest Evolution of the Medtronic CoreValve System in the Era of Transcatheter Aortic Valve Replacement Matched Comparison of the Evolut PRO and Evolut R [J].
Hellhammer, Katharina ;
Piayda, Kerstin ;
Afzal, Shazia ;
Kleinebrecht, Laura ;
Makosch, Matthias ;
Hennig, Inga ;
Quast, Christine ;
Jung, Christian ;
Polzin, Amin ;
Westenfeld, Ralf ;
Kelm, Malte ;
Zeus, Tobias ;
Veulemans, Verena .
JACC-CARDIOVASCULAR INTERVENTIONS, 2018, 11 (22) :2314-2322
[6]   Minimizing Permanent Pacemaker Following Repositionable Self-Expanding Transcatheter Aortic Valve Replacement [J].
Jilaihawi, Hasan ;
Zhao, Zhengang ;
Du, Run ;
Staniloae, Cezar ;
Saric, Muhamed ;
Neuburger, Peter J. ;
Querijero, Michael ;
Vainrib, Alan ;
Hisamoto, Kazuhiro ;
Ibrahim, Homam ;
Collins, Tara ;
Clark, Emily ;
Pushkar, Illya ;
Bamira, Daniel ;
Benenstein, Ricardo ;
Tariq, Afnan ;
Williams, Mathew .
JACC-CARDIOVASCULAR INTERVENTIONS, 2019, 12 (18) :1796-1807
[7]   Comparison of the self-expanding Evolut-PRO transcatheter aortic valve to its predecessor Evolut-R in the real world multicenter ATLAS registry [J].
Kalogeras, Konstantinos ;
Ruparelia, Neil ;
Kabir, Tito ;
Jabbour, Richard ;
Naganuma, Toru ;
Vavuranakis, Manolis ;
Nakamura, Sunao ;
Wang, Brian ;
Sen, Sayan ;
Hadjiloizou, Nearchos ;
Malik, Iqbal S. ;
Mikhail, Ghada ;
Dalby, Miles ;
Panoulas, Vasileios .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2020, 310 :120-125
[8]   Impact of implantation depth on outcomes of new-generation balloon-expandable transcatheter heart valves [J].
Kim, Won-Keun ;
Renker, Matthias ;
Doerr, Oliver ;
Hofmann, Simon ;
Nef, Holger ;
Choi, Yeong-Hoon ;
Hamm, Christian W. .
CLINICAL RESEARCH IN CARDIOLOGY, 2021, 110 (12) :1983-1992
[9]   Transcatheter or Surgical Aortic-Valve Replacement in Intermediate-Risk Patients [J].
Leon, Martin B. ;
Smith, Craig R. ;
Mack, Michael J. ;
Makkar, Raj R. ;
Svensson, Lars G. ;
Kodali, Susheel K. ;
Thourani, Vinod H. ;
Tuzcu, E. Murat ;
Miller, D. Craig ;
Herrmann, Howard C. ;
Doshi, Darshan ;
Cohen, David J. ;
Pichard, Augusto D. ;
Kapadia, Samir ;
Dewey, Todd ;
Babaliaros, Vasilis ;
Szeto, Wilson Y. ;
Williams, Mathew R. ;
Kereiakes, Dean ;
Zajarias, Alan ;
Greason, Kevin L. ;
Whisenant, Brian K. ;
Hodson, Robert W. ;
Moses, Jeffrey W. ;
Trento, Alfredo ;
Brown, David L. ;
Fearon, William F. ;
Pibarot, Philippe ;
Hahn, Rebecca T. ;
Jaber, Wael A. ;
Anderson, William N. ;
Alu, Maria C. ;
Webb, John G. .
NEW ENGLAND JOURNAL OF MEDICINE, 2016, 374 (17) :1609-1620
[10]   Prevalence of and Risk Factors for Permanent Pacemaker Implantation After Aortic Valve Replacement [J].
Levack, Melissa M. ;
Kapadia, Samir R. ;
Soltesz, Edward G. ;
Gillinov, A. Marc ;
Houghtaling, Penny L. ;
Navia, Jose L. ;
Krishnaswamy, Amar ;
Blackstone, Eugene H. ;
Svensson, Lars G. ;
Mick, Stephanie L. .
ANNALS OF THORACIC SURGERY, 2019, 108 (03) :700-707