Seasonal field study on thermal comfort in university classrooms in Mediterranean climate

被引:1
作者
de la Hoz-torres, Maria L. [1 ]
Aguilar, Antonio J. [1 ,3 ]
Martinez-Aires, Maria Dolores [1 ]
Ruiz, Diego P. [2 ]
机构
[1] Univ Granada, Adv Tech Sch Bldg Engn, Dept Bldg Construct, Granada, Spain
[2] Univ Granada, Fac Sci, Dept Appl Phys, Granada, Spain
[3] Univ Granada, Dept Bldg Construct, Ave Severo Ochoa S N, Granada 18071, Spain
关键词
Thermal comfort; Indoor environmental conditions; Adaptive thermal comfort; University building; Natural ventilation; Neutral temperature; NATURALLY VENTILATED CLASSROOMS; EDUCATIONAL BUILDINGS; ENVIRONMENT; ADAPTATION; PERCEPTION; AIR; PREFERENCE; OCCUPANTS; OFFICES; QUALITY;
D O I
10.1177/1420326X241241530
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The assessment of indoor environmental conditions of educational buildings is not only essential to ensure the correct performance of heating, cooling and ventilation systems but it is also fundamental to guarantee a suitable environment. This study aims to analyse the thermal comfort of students in teaching-learning spaces in university buildings with natural ventilation. A field measurement campaign and a questionnaire survey were carried out from September 2021 to June 2022 in educational buildings in southern Spain. The collected data were analysed and the neutral temperature in each season was obtained, based on the thermal sensation votes of 1966. The neutral temperatures found in this study were 23.5 degrees C, 23.1 degrees C, 23.3 degrees C and 23.9 degrees C, for autumn, winter, spring and summer, respectively. The ranges obtained for 90% acceptability in the winter season (21.1 degrees C-25.1 degrees C) provided lower temperature limits than the ranges obtained in the summer months (22.6 degrees C-25.3 degrees C). The highest values for clothing insulation were found in the autumn (0.90 clo) and winter (0.75 clo) seasons, compared to the spring (0.5 clo) and summer (0.4 clo) seasons. An adaptive thermal comfort model was applied. These findings could be used to improve thermal comfort and to optimise energy consumption according to the students' actual thermal perception.
引用
收藏
页码:1380 / 1396
页数:17
相关论文
共 51 条
  • [1] Thermal Perception in Naturally Ventilated University Buildings in Spain during the Cold Season
    Aguilar, Antonio J.
    de la Hoz-Torres, Maria L.
    Dolores Martinez-Aires, Maria
    Ruiz, Diego P.
    [J]. BUILDINGS, 2022, 12 (07)
  • [2] Impact of COVID-19 protocols on IEQ and students' perception within educational buildings in Southern Spain
    Aguilar, Antonio J.
    de la Hoz-Torres, Maria L.
    Oltra-Nieto, Lamberto
    Ruiz, Diego P.
    Martinez-Aires, M. Dolores
    [J]. BUILDING RESEARCH AND INFORMATION, 2022, 50 (07) : 755 - 770
  • [3] [Anonymous], 2007, Indoor environmental input parameters for design and assessment of energy performance of buildings-addressing indoor air quality, thermal environment, lighting and acoustics
  • [4] [Anonymous], 1998, ISO 7726
  • [5] [Anonymous], 2023, ANSIASHRAE 55 2023 T
  • [6] [Anonymous], 2007, ROYAL DECREE 1027200
  • [7] A field study on adaptive thermal comfort in Spanish primary classrooms during summer season
    Aparicio-Ruiz, Pablo
    Barbadilla-Martin, Elena
    Guadix, Jose
    Munuzuri, Jesus
    [J]. BUILDING AND ENVIRONMENT, 2021, 203
  • [8] Influence of non-uniform distribution of fan-induced air on thermal comfort conditions in university classrooms in warm and humid climate, India
    Bhandari, Nikhil
    Tadepalli, Srinivas
    Gopalakrishnan, Padmanaban
    [J]. BUILDING AND ENVIRONMENT, 2023, 238
  • [9] Holistic overview of natural ventilation and mixed mode in built environment of warm climate zones and hot seasons
    Bienvenido-Huertas, David
    de la Hoz-Torres, Maria Luisa
    Aguilar, Antonio J.
    Tejedor, Blanca
    Sanchez-Garcia, Daniel
    [J]. BUILDING AND ENVIRONMENT, 2023, 245
  • [10] Chazarra A., 2022, EVOLUCION CLIMAS KOP, DOI [10.31978/666-22-011-4, DOI 10.31978/666-22-011-4]