Transvenous lead extraction at the University of Szeged: 10-year experience

被引:0
作者
Saghy Laszlo [1 ,2 ]
Zsigmond Elod Janos [1 ]
Benak Attila [1 ]
Makai Attila [1 ]
Miklos Marton [1 ]
Klausz Gergely [1 ]
Vamos Mate [1 ]
机构
[1] Szeged Tud Egyet, Szent Gyorgy Albert Orvostud Kar, Belgyogyaszat Klin, Elektrofiziol Reszleg, Szeged, Hungary
[2] Semmelweis U 8, H-6725 Szeged, Hungary
关键词
extraction; lead; transvenous; pacemaker; ICD; CRT; cardiac implantable electronic device; CIED; EXPERT CONSENSUS STATEMENT; DEFIBRILLATOR; PREDICTORS; PACEMAKER; EFFICACY; OUTCOMES; SAFETY;
D O I
10.1556/650.2023.32893
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Cardiac implantable electronic device-related complications may require transvenous lead extraction. Data on procedure complexity and outcomes are derived from international registries. However, patient characteristics vary considerably between countries.Objective: To summarize the results of the 10-year systematic institutional extraction program and compare it with international data.Methods: We retrospectively analyzed consecutive patients undergoing extraction between 2012 and 2020. Data regarding patient characteristics, indications, techniques and outcomes of the procedures were collected and compared with the results of the largest comprehensive European registry (ELECTRa). We also examined success rates at different levels of the "stepwise approach".Results: 200 patients (65 +/- 14.3 years, 74.5% male) were included. The indication of extraction was predominantly infectious, exceeding the rate reported in ELECTRa (87.5% vs. 52.8%, p<0.001). Lead dwelling time was also longer in our study (7.8 +/- 6.2 vs. 6.4 +/- 5.4 years). The number of passive fixation leads was found to be also significantly higher (62.2% vs. 46.6%, p<0.001). One fifth of our patients had previously undergone a failed extraction attempt. A higher proportion of patients required the use of locking stylets (81.9% vs. 71.1%, p<0.001) and active extraction sheaths (71.8% vs. 27.1%, p<0.001). Major complications occurred in 4.5% and procedural death in 4 cases (2%). Procedural success was 88.2%, which is lower than the 95.7% reported in ELECTRa. In the stepwise approach analysis, cumulative clinical success rate was 24.8% with locking stylets, 74.2% with the primary active sheaths, 91.3% with advanced extraction techniques (crossover, femoral snare) and 96.6% with non-emergency cardiac surgery.Discussion and conclusion: In the last 10 years, a successful lead extraction program has been developed in our institution. Patient risk and procedure complexity far exceed those reported by international registries. To achieve optimal outcomes, the availability of diverse extraction techniques, experience as well as close educational and referral cooperation with implanting centers are essential.
引用
收藏
页码:1954 / 1964
页数:11
相关论文
共 24 条
  • [1] Benak A, 2017, CARDIOL HUNG, V47, P214
  • [2] Management of cardiac implantable electronic device infection using a complete interdisciplinary approachTherapie einer mit einem kardialen implantierbaren elektronischen Gerät assoziierten Infektion nach einem kompletten interdisziplinären Ansatz
    Attila Benak
    Maria Kohari
    Zsuzsanna Besenyi
    Attila Makai
    Laszlo Saghy
    Mate Vamos
    [J]. Herzschrittmachertherapie + Elektrophysiologie, 2021, 32 (1) : 124 - 127
  • [3] 2018 EHRA expert consensus statement on lead extraction: recommendations on definitions, endpoints, research trial design, and data collection requirements for clinical scientific studies and registries: endorsed by APHRS/HRS/LAHRS
    Bongiorni, Maria G.
    Burri, Haran
    Deharo, Jean C.
    Starck, Christoph
    Kennergren, Charles
    Saghy, Laszlo
    Rao, Archana
    Tascini, Carlo
    Lever, Nigel
    Kutarski, Andrzej
    Lozano, Ignacio Fernandez
    Strathmore, Neil
    Costa, Roberto
    Epstein, Laurence
    Love, Charles
    Blomstrom-Lundqvist, Carina
    Fauchier, Laurent
    Defaye, Pascal
    Arnar, David O.
    Klug, Didier
    Boveda, Serge
    Nielsen, Jens Cosedis
    Boriani, Giuseppe
    Zhang, Shu
    Martin, Andrew Paul
    Prutkin, Jordan M.
    de Zuloaga, Claudio
    [J]. EUROPACE, 2018, 20 (07): : 1217 - +
  • [4] The European Lead Extraction ConTRolled (ELECTRa) study: a European Heart Rhythm Association (EHRA) Registry of Transvenous Lead Extraction Outcomes
    Bongiorni, Maria Grazia
    Kennergren, Charles
    Butter, Christian
    Deharo, Jean Claude
    Kutarski, Andrzej
    Rinaldi, Christopher A.
    Romano, Simone L.
    Maggioni, Aldo P.
    Andarala, Maryna
    Auricchio, Angelo
    Kuck, Karl-Heinz
    Blomstrom-Lundqvist, Carina
    [J]. EUROPEAN HEART JOURNAL, 2017, 38 (40) : 2995 - 3005
  • [5] Pacemaker and Defibrillator Lead Extraction
    Buch, Eric
    Boyle, Noel G.
    Belott, Peter H.
    [J]. CIRCULATION, 2011, 123 (11) : E378 - E380
  • [6] Predictors of long-termsurvival free from relapses after extraction of infected CIED
    Diemberger, Igor
    Biffi, Mauro
    Lorenzetti, Stefano
    Martignani, Cristian
    Raffaelli, Elena
    Ziacchi, Matteo
    Rapezzi, Claudio
    Pacini, Davide
    Boriani, Giuseppe
    [J]. EUROPACE, 2018, 20 (06): : 1018 - 1027
  • [7] Outcomes and complications of lead removal: Can we establish a risk stratification schema for a collaborative and effective approach? (vol 38, pg 1439, 2015)
    Fu, H. X.
    Huang, X. M.
    Zhong, L.
    Osborn, M. J.
    Asirvatham, S. J.
    Espinosa, R. E.
    Brady, P. A.
    Lee, H. C.
    Greason, K. L.
    Baddour, L. M.
    Sohail, M. R.
    Acker, N. G.
    Hodge, D. O.
    Friedman, P. A.
    Cha, Y. M.
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2016, 39 (02): : 205 - 205
  • [8] Outcomes and Complications of Lead Removal: Can We Establish a Risk Stratification Schema for a Collaborative and Effective Approach?
    Fu, Hai-Xia
    Huang, Xin-Miao
    Zhong, Li
    Osborn, Michael J.
    Asirvatham, Samuel J.
    Espinosa, Raul E.
    Brady, Peter A.
    Lee, Hon-Chi
    Greason, Kevin L.
    Baddour, Larry M.
    Sohail, Rizwan M.
    Acker, Nancy G.
    Hodge, David O.
    Friedman, Paul A.
    Cha, Yong-Mei
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2015, 38 (12): : 1439 - 1447
  • [9] Deaths and cardiovascular injuries due to device-assisted implantable cardioverter-defibrillator and pacemaker lead extraction
    Hauser, Robert G.
    Katsiyiannis, William T.
    Gornick, Charles C.
    Almquist, Adrian K.
    Kallinen, Linda M.
    [J]. EUROPACE, 2010, 12 (03): : 395 - 401
  • [10] Transvenous Lead Extraction SAFeTY Score for Risk Stratification and Proper Patient Selection for Removal Procedures Using Mechanical Tools
    Jachec, Wojciech
    Polewczyk, Anna
    Polewczyk, Maciej
    Tomasik, Andrzej
    Kutarski, Andrzej
    [J]. JOURNAL OF CLINICAL MEDICINE, 2020, 9 (02)