Automatic irrigation system with a fiber-optic pressure sensor regulating intrapelvic pressure for flexible ureteroscopy

被引:1
|
作者
Yoshida, Takashi [1 ,2 ]
Tsuruoka, Noriko [3 ]
Haga, Yoichi [3 ,4 ]
Kinoshita, Hidefumi [2 ]
Lee, Sang-Seok [1 ,5 ]
Matsunaga, Tadao [1 ,5 ]
机构
[1] Tottori Univ, Grad Sch Engn, Tottori, Japan
[2] Kansai Med Univ, Dept Urol & Androl, Osaka, Japan
[3] Tohoku Univ, Grad Sch Engn, Sendai, Japan
[4] Tohoku Univ, Grad Sch Biomed Engn, Sendai, Japan
[5] Tottori Univ, Fac Engn, Adv Mech & Elect Syst Res Ctr, 4-101 Koyama Minami, Tottori 6808552, Japan
关键词
D O I
10.1038/s41598-023-47373-5
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Increased intrapelvic pressure (IPP) due to irrigation during flexible ureteroscopy (f-URS) can pose a risk of postoperative severe urinary tract infection associated with pyelovenous backflow. An automatic regulation system for maintaining safe IPP levels could enable surgeons to perform f-URS safely without postoperative complications. This study aimed to assess the measurement accuracy of an ultra-miniature fiber-optic pressure sensor incorporated into a small-caliper ureteroscope for assessing IPP and to develop an automatic irrigation system linked to this sensor. A porcine kidney was used for the ex vivo experiment. The nephrostomy catheter, connected to the conventional pressure transducer, was placed on the renal pelvis to evaluate the actual IPP (a-IPP). For measuring IPP using the fiber-optic pressure sensor (fo-IPP) built into the f-URS, a diaphragm pressure sensor of phi 250 mu m was used. To establish an irrigation system, the optimal proportional-integral-derivative (PID) controller was explored to accurately adjust the irrigation pump flow rate. A high correlation between a-IPP and fo-IPP was confirmed across irrigation pressure values of 60-180 mbar (all, r >= 0.7, p < 0.001). When performing bolus irrigation, although fo-IPP showed relatively a higher peak value than a-IPP, the response time of fo-IPP was equivalent to that of a-IPP. After PID parameter optimization, our automatic irrigation system based on fo-IPP smoothly and accurately regulated the intended IPP set in the 5-20 mmHg range without overshooting. We successfully developed and demonstrated an automatic irrigation system regulating IPP based on the PID controller for f-URS, utilizing a fiber-optic pressure sensor. Further research, including in vivo studies, will be needed to assess clinical feasibility.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Temperature desensitization of a fiber-optic pressure sensor by simultaneous measurement of pressure and temperature
    Bock, WJ
    Urbanczyk, W
    APPLIED OPTICS, 1998, 37 (18): : 3897 - 3901
  • [22] An irrigation system for noninvasively estimating intrarenal pressure during flexible ureteroscopy
    Shu, Xiongpeng
    Hua, Peng
    Xie, Le
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2021, 17 (05):
  • [23] Highly sensitive fiber-optic sensor for dynamic pressure measurements
    Bock, WJ
    Nawrocka, MS
    Urbanczyk, W
    Rostkowski, J
    IMTC/2000: PROCEEDINGS OF THE 17TH IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE: SMART CONNECTIVITY: INTEGRATING MEASUREMENT AND CONTROL, 2000, : 591 - 594
  • [24] Intrinsic single-mode fiber-optic pressure sensor
    Zhao, Y
    Ansari, F
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2001, 13 (11) : 1212 - 1214
  • [25] Highly sensitive fiber-optic sensor for dynamic pressure measurements
    Nawrocka, MS
    Bock, WJ
    Urbanczyk, W
    Wójcik, J
    INTERFEROMETRY '99: APPLICATIONS, 1999, 3745 : 293 - 297
  • [26] Temperature and Pressure Sensor Based on Polished Fiber-Optic Microcavity
    Yang, Musen
    Zhu, Yunlong
    An, Ran
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2022, 34 (11) : 607 - 610
  • [27] Fiber-optic combustion pressure sensor for automotive engine controls
    Wlodarczyk, MT
    LASER DIODE AND LED APPLICATIONS III, 1997, 3000 : 51 - 59
  • [28] Development of ultra-miniature fiber-optic pressure sensor
    Totsu, Kentaro
    Haga, Yoichi
    Matsunaga, Tadao
    Esashi, Masayoshi
    FUTURE MEDICAL ENGINEERING BASED ON BIONANOTECHNOLOGY, PROCEEDINGS, 2006, : 529 - +
  • [29] Highly sensitive fiber-optic sensor for dynamic pressure measurements
    Bock, WJ
    Nawrocka, MS
    Urbanczyk, W
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2001, 50 (05) : 1085 - 1088
  • [30] Fiber-optic sensor for simultaneous measurements of pressure and temperature changes
    Nawrocka, MS
    Urbanczyk, W
    Bock, WJ
    12TH CZECH-SLOVAK-POLISH OPTICAL CONFERENCE ON WAVE AND QUANTUM ASPECTS OF CONTEMPORARY OPTICS, 2001, 4356 : 248 - 253