Best Practices for Body Temperature Measurement with Infrared Thermography: External Factors Affecting Accuracy

被引:12
作者
Mazdeyasna, Siavash [1 ]
Ghassemi, Pejman [1 ]
Wang, Quanzeng [1 ]
机构
[1] US FDA, Ctr Devices & Radiol Hlth, Silver Spring, MD 20993 USA
关键词
elevated body temperature; infrared thermograph; thermography; ISO/TR; 13154; viewing angle; external temperature reference source; ambient temperature; relative humidity; atmosphere transmittance; environmental effects; accuracy; OUTDOOR THERMAL COMFORT; SURFACE-TEMPERATURE; SPECTRAL EMISSIVITY; SKIN TEMPERATURE; FEVER; ACCLIMATIZATION; ADAPTATION; ANGLE;
D O I
10.3390/s23188011
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Infrared thermographs (IRTs) are commonly used during disease pandemics to screen individuals with elevated body temperature (EBT). To address the limited research on external factors affecting IRT accuracy, we conducted benchtop measurements and computer simulations with two IRTs, with or without an external temperature reference source (ETRS) for temperature compensation. The combination of an IRT and an ETRS forms a screening thermograph (ST). We investigated the effects of viewing angle (theta, 0-75 degrees), ETRS set temperature (TETRS, 30-40 degrees C), ambient temperature (Tatm, 18-32 degrees C), relative humidity (RH, 15-80%), and working distance (d, 0.4-2.8 m). We discovered that STs exhibited higher accuracy compared to IRTs alone. Across the tested ranges of Tatm and RH, both IRTs exhibited absolute measurement errors of less than 0.97 degrees C, while both STs maintained absolute measurement errors of less than 0.12 degrees C. The optimal TETRS for EBT detection was 36-37 degrees C. When theta was below 30 degrees, the two STs underestimated calibration source (CS) temperature (TCS) of less than 0.05 degrees C. The computer simulations showed absolute temperature differences of up to 0.28 degrees C and 0.04 degrees C between estimated and theoretical temperatures for IRTs and STs, respectively, considering d of 0.2-3.0 m, Tatm of 15-35 degrees C, and RH of 5-95%. The results highlight the importance of precise calibration and environmental control for reliable temperature readings and suggest proper ranges for these factors, aiming to enhance current standard documents and best practice guidelines. These insights enhance our understanding of IRT performance and their sensitivity to various factors, thereby facilitating the development of best practices for accurate EBT measurement.
引用
收藏
页数:24
相关论文
共 47 条
[21]   The influencing factors and an error correction method of the use of infrared thermography in human facial skin temperature [J].
Tian, Xiaoyu ;
Fang, Lei ;
Liu, Weiwei .
BUILDING AND ENVIRONMENT, 2023, 244
[22]   External Field Measurement Method of Target Infrared Radiance with Environmental Temperature Correction [J].
Gan, Shiqi ;
Wang, Weichao ;
Yuan, Guangfu ;
Zhang, Xiao ;
Ma, Xin ;
Qin, Hetao .
ACTA OPTICA SINICA, 2025, 45 (03)
[23]   Influences of Target Distance and Angle on Temperature Measurement Accuracy of Infrared Thermal Imager [J].
Zhang Z. ;
Wang P. ;
Zhao S. ;
Yu X. ;
Zhou Y. .
Tianjin Daxue Xuebao (Ziran Kexue yu Gongcheng Jishu Ban)/Journal of Tianjin University Science and Technology, 2021, 54 (07) :763-770
[24]   MODIS land surface temperature in East Antarctica: accuracy and its main affecting factors [J].
Zhai, Zhaosheng ;
Wang, Yetang ;
Reijmer, Carleen H. ;
Smeets, Paul C. J. P. ;
Zhang, Xueying ;
Zhang, Wuying .
JOURNAL OF GLACIOLOGY, 2024, 70
[25]   A sampling strategy for the determination of infrared temperature of relevant external body surfaces of dairy cows [J].
Uddin, Jashim ;
McNeill, David M. ;
Lisle, Allan T. ;
Phillips, Clive J. C. .
INTERNATIONAL JOURNAL OF BIOMETEOROLOGY, 2020, 64 (09) :1583-1592
[26]   Touch-free measurement of body temperature using close-up thermography of the ocular surface [J].
Vogel, Benjamin ;
Wagner, Heike ;
Gmoser, Johanna ;
Woernerc, Anja ;
Loeshberger, Anna ;
Peters, Laura ;
Frey, Anna ;
Hofmann, Ulrich ;
Frantz, Stefan .
METHODSX, 2016, 3 :407-416
[27]   Infrared thermography measured body surface temperature and its relationship with rectal temperature in dairy cows under different temperature-humidity indexes [J].
Peng, D. ;
Chen, S. ;
Li, G. ;
Chen, J. ;
Wang, J. ;
Gu, X. .
INTERNATIONAL JOURNAL OF BIOMETEOROLOGY, 2019, 63 (03) :327-336
[28]   Body temperature measurement in pigs: Are infrared thermometers a non-invasive alternative? [J].
Koch, Felicitas ;
Pieper, Robert ;
Fischer-Tenhagen, Carola .
TIERAERZTLICHE PRAXIS AUSGABE GROSSTIERE NUTZTIERE, 2023, 51 (02) :84-92
[29]   A nanocomposite coating improving the accuracy in infrared temperature measurement for thermal micro-devices [J].
Wang, Yipin ;
Cheng, Ping ;
Liu, Qi ;
Sun, Yunna ;
Zhang, Xiaojing ;
Chen, Jiaming ;
Ding, Guifu .
SENSORS AND ACTUATORS A-PHYSICAL, 2019, 293 :29-36
[30]   Factors affecting the daily rhythm of body temperature of captive mouse lemurs (Microcebus murinus) [J].
M. Séguy ;
M. Perret .
Journal of Comparative Physiology B, 2005, 175 :107-115