Tissue characterization of renal masses using Nakagami-modeling of ultrasound-based texture

被引:0
|
作者
Varghese, Bino A. [1 ]
Rivas, Marielena [2 ]
Cen, Steven [1 ]
Lei, Xiaomeng [1 ]
Chang, Michael [3 ]
Lee, KwangJu [4 ]
Jamie, Janet [1 ]
Amoedo, Renata L. [5 ]
Franco, Mario [1 ]
Hwang, Darryl H. [1 ]
Desai, Bhushan [1 ]
King, Kevin G. [6 ]
Cheng, Phillip M. [1 ]
Duddalwar, Vinay [1 ]
机构
[1] Univ Southern Calif, Keck Sch Med, Los Angeles, CA 90007 USA
[2] Richmond Univ, Med Ctr, Staten Isl, NY USA
[3] Icahn Sch Med Mt Sinai, New York, NY USA
[4] Samsung Medison Co Ltd, Seoul, South Korea
[5] Hosp Sao Rafael Rede Or, Salvador, BA, Brazil
[6] Univ Calif Los Angeles, David Geffen Sch Med, Los Angeles, CA USA
来源
18TH INTERNATIONAL SYMPOSIUM ON MEDICAL INFORMATION PROCESSING AND ANALYSIS | 2023年 / 12567卷
关键词
Renal mass; Radiofrequency data; tissue characterization; B-mode; CEUS; Nakagami parameter; BACKSCATTERING; CLASSIFICATION;
D O I
10.1117/12.2670273
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
In this Institutional Review Board (IRB) approved, Health Insurance Portability and Accountability Act (HIPAA) compliant, prospective study, uncompressed envelope data (RF data) were collected from 100 patients with focal renal masses using an RS80A ultrasound scanner with B-mode and CEUS. By summing and averaging the Nakagami images formed using sliding windows, we use the average `m' to stratify manually segmented masses, using data from both the B-mode and CEUS scans. Wilcoxon rank sum test using an alpha value of 0.05 was used detect differences between the groups. Logistic regression was used for classification and the area under the receiver operator curve (AUC) was used to assess performance. Among the 100 masses, 40 were benign, 37 were malignant based on histopathology, and 23 were radiologically and clinically presumed malignant but with no pathological proof at the time of data analysis. Univariate analyses showed significant (p<0.01) differences between the benign and non- benign masses on both B- mode and CEUS, with non-benign masses having smaller `m'. Predictive models constructed using Nakagami parameters extracted from B-mode and CEUS-based RF scans showed an AUC of 0.67 95% CI: (0.56, 0.78) and 0.61 95% CI: (0.5, 0.73), respectively for discriminating benign from non-benign renal masses. The concordance between the two assessments was 95%. We present a framework for characterizing images using speckle textural properties, for example Nakagami analysis, to aid in objective tissue characterization using ultrasound.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Modeling of needle-tissue interaction using ultrasound-based motion estimation
    Dehghan, Ehsan
    Wen, Xu
    Zahiri-Azar, Reza
    Marchal, Maud
    Salcudean, Septimiu E.
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2007, PT 1, PROCEEDINGS, 2007, 4791 : 709 - +
  • [2] Tissue Characterization on Ultrasound Harmonic Signals using Nakagami Statistics
    Lin, Fanglue
    Cristea, Anca
    Cachard, Christian
    Basset, Olivier
    Proceedings of the 2015 ICU International Congress on Ultrasonics, 2015, 70 : 1165 - 1168
  • [3] Introduction to the Special Issue on Quantitative Ultrasound-Based Tissue Characterization
    Lavarello, Roberto J.
    Urban, Matthew W.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2016, 63 (09) : 1231 - 1233
  • [4] An expectation maximization framework for an improved ultrasound-based tissue characterization
    Alessandrini, Martino
    Maggio, Simona
    Poree, Jonathan
    De Marchi, Luca
    Speciale, Nicolo
    Franceschini, Emilie
    Bernard, Olivier
    Basset, Olivier
    MEDICAL IMAGING 2011: ULTRASONIC IMAGING, TOMOGRAPHY, AND THERAPY, 2011, 7968
  • [5] Characterization of Renal Masses by Ultrasound
    Fulgham, Pat F.
    JOURNAL OF UROLOGY, 2017, 197 (02): : S121 - S121
  • [6] Cystic renal masses as an incidental finding — ultrasound-based diagnostic algorithm and therapeutic consequences
    Stock K.F.
    Kübler H.
    Holzapfel K.
    MMW - Fortschritte der Medizin, 2017, 159 (6) : 60 - 65
  • [7] Needle-tissue interaction modeling using ultrasound-based motion estimation: Phantom study
    Dehghan, Ehsan
    Wen, Xu
    Zahiri-Azar, Reza
    Marchal, Maud
    Salcudean, Septimiu E.
    COMPUTER AIDED SURGERY, 2008, 13 (05) : 265 - 280
  • [8] A Review on Ultrasound-based Thyroid Cancer Tissue Characterization and Automated Classification
    Acharya, U. Rajendra
    Swapna, G.
    Sree, S. Vinitha
    Molinari, Filippo
    Gupta, Savita
    Bardales, Ricardo H.
    Witkowska, Agnieszka
    Suri, Jasjit S.
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2014, 13 (04) : 289 - 301
  • [9] Intravascular ultrasound-based tissue characterization using modular network self-organizing map
    Tokunaga, Kazuhiro
    Uchino, Eiji
    Tanaka, Hiroki
    Suetake, Noriaki
    APPLIED SOFT COMPUTING, 2016, 44 : 89 - 100
  • [10] Potential of Ultrasound Nakagami Imaging in Clinical Tissue Characterization
    Tsui, Po-Hsiang
    JOURNAL OF MEDICAL ULTRASOUND, 2013, 21 (02) : 51 - 53