Significant Lightning Stroke Count in Negative Ground Flashes Featuring the Relationship of Preliminary Breakdown and The First Return Stroke

被引:0
|
作者
Isa, Nur Asyiqin Binti Mohd [1 ]
Baharudin, Zikri Abadi [2 ]
Zainuddin, Hidayat [1 ]
机构
[1] Univ Teknikal Malaysia Melaka, Fak Kejuruteraan Elekt, Hang Tuah Jaya 76100, Durian Tunggal, Malaysia
[2] Univ Tekn Malaysia Melaka, Fak Teknol Kejuruteraan Elekt & Elekt, Melaka 76100, Hang Tuah Jaya, Malaysia
来源
INTERNATIONAL JOURNAL OF INTEGRATED ENGINEERING | 2023年 / 15卷 / 01期
关键词
Stroke count; PB; RS ratio; PB-RS duration; return stroke; tropical monsoon; ELECTRIC-FIELD; LEADERS;
D O I
10.30880/ijie.2023.15.01.022
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The separation duration of Preliminary Breakdown (PB) to the First Return Stroke (PB-RS duration) and the ratio between the highest amplitude pulse of negative CG flashes and the first Return Stroke pulse (PB/RS ratio) were successfully used as a tool by many researchers to determine the relationship between lightning ground flashes and physical changes (latitude, regional and thunderstorm). Malaysia is one of the countries with the highest lightning flash density globally, and the occurrences of ground flashes are mainly due to monsoon seasons. Monsoons in Malaysia are Northeast, Southwest, and two transition periods. However, there is no available information to relate the lightning activities in Malaysia under the influence of all monsoon seasons. The above statements motivated our team to present a new statistical analysis of lightning flashes under two seasons' effects (Northeast and Southwest). 83 out of 332 electric radiation field data (fast fields) from six thunderstorms were selected and analyzed. The data recorded were using a 12-bit high-speed transient recorder (HDO 4024) with a resolution of tens of nanoseconds and sampling of 12.5 MS/s. PB/RS ratio between the monsoons is similar to each other. The PB-RS separation has two factors longer during the Southwest monsoon than during the Northeast monsoon. We classified the PB/RS ratio into four categories (>100%, 50-100%, 20-50%, and < 20%) as an indication of the preliminary breakdown strength. It found that the weakest pulse train (PB/RS ratio less than 20%) has shown a longer duration of PB-RS and produces higher lightning return strokes in a negative ground flash than the strong one. The results of this study could be evident that the lower strength of preliminary breakdown correlates to a lower Low Positive Charge Region (LPCR), which means the initial breakdown process only requires low energy to break the LPCR. Hence, these features have shown the highest number of stroke counts compared to pronounced ones. However, it would be more remarkable if one could provide bulky data for this specific study.
引用
收藏
页码:248 / 258
页数:11
相关论文
共 18 条
  • [1] Some Return Stroke Characteristics of Negative Lightning Flashes Recorded at the Peissenberg Tower
    Heidler, Fridolin H.
    Paul, Christian
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2017, 59 (05) : 1490 - 1497
  • [2] ` A Study of Preliminary Breakdown and Return Stroke Processes in High-Intensity Negative Lightning Discharges
    Zhu, Yanan
    Rakov, Vladimir A.
    Tran, Manh D.
    ATMOSPHERE, 2016, 7 (10):
  • [3] Correlation Between Speed of the Leader and Peak Current of the Return Stroke in Negative Lightning Flashes
    Cruz, Ivan T.
    Saba, Marcelo M. F.
    Silva, Jose Claudio O.
    Abbasi, Rasha U.
    Hunt, Hugh G. P.
    Schumann, Carina
    da Silva, Diego R. R.
    da Silva, Tagianne P.
    Lauria, Paola B.
    Kieu, Ny T.
    GEOPHYSICAL RESEARCH LETTERS, 2025, 52 (02)
  • [4] Latitude and Topographical Dependence of Lightning Return Stroke Peak Current in Natural and Tower-Initiated Negative Ground Flashes
    Cooray, Vernon
    Rubinstein, Marcos
    Rachidi, Farhad
    ATMOSPHERE, 2020, 11 (06)
  • [5] Frequency distributions of some parameters of negative downward lightning flashes based on accurate-stroke-count studies
    Ballarotti, Mauricio G.
    Medeiros, Claudia
    Saba, Marcelo M. F.
    Schulz, Wolfgang
    Pinto, Osmar, Jr.
    JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 2012, 117
  • [6] A unified engineering model of the first stroke in downward negative lightning
    Nag, Amitabh
    Rakov, Vladimir A.
    JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 2016, 121 (05) : 2188 - 2204
  • [7] Some features of negative cloud-to-ground flashes from a local thunderstorm based on accurate-stroke-count study
    Zhu Baoyou
    Ma Ming
    Xu Weiwei
    Ma Dong
    2014 INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP), 2014, : 1657 - 1660
  • [8] Some properties of negative cloud-to-ground flashes from observations of a local thunderstorm based on accurate-stroke-count studies
    Zhu, Baoyou
    Ma, Ming
    Xu, Weiwei
    Ma, Dong
    JOURNAL OF ATMOSPHERIC AND SOLAR-TERRESTRIAL PHYSICS, 2015, 136 : 16 - 22
  • [9] Model of the First Lightning Return Stroke Using Bidirectional Leader Concept
    Kaspar, Petr
    Kolmasova, Ivana
    Santolik, Ondrej
    JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 2022, 127 (24)
  • [10] Characteristics of the initial stage and return stroke currents of rocket-triggered lightning flashes in southern China
    Zheng, Dong
    Zhang, Yijun
    Zhang, Yang
    Lu, Weitao
    Yan, Xu
    Chen, Shaodong
    Xu, Liangtao
    Huang, Zhigang
    You, Jin
    Zhang, Rong
    Su, Zhiguo
    JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 2017, 122 (12) : 6431 - 6452