Effect of key parameters on the transient thermal performance of a building envelope with Trombe wall containing phase change material

被引:32
作者
Zhou, Shiqiang [1 ]
Bai, Fan [1 ]
Razaqpur, Ghani [1 ,2 ]
Wang, Bing [1 ]
机构
[1] Nankai Univ, Coll Environm Sci & Engn, Sino Canada Joint R&D Ctr Water & Environm Safety, Tianjin, Peoples R China
[2] McMaster Univ, Dept Civil Engn, Hamilton, ON, Canada
关键词
Building envelope; CFD; Phase change material; Transient analysis; Trombe wall; HEAT-TRANSFER; STORAGE WALL; ENERGY PERFORMANCE; NATURAL-CONVECTION; SYSTEM; OPTIMIZATION; SIMULATION; DESIGN; FLOW;
D O I
10.1016/j.enbuild.2023.112879
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The thermal behavior of a building envelope having a Trombe wall incorporating phase change material (PCM) is investigated during heating season, using experimentally validated 3D computational fluid dynamics (CFD) simulations. The effects of transient versus steady-state ambient irradiation and temper-ature, presence of PCM and different solar irradiation intensities on the spatial and temporal variation of temperature and airflow rate in the conditioned room are investigated. The results show that the flow transition and temperature rise mainly happen in the near-wall regions close to the room ceiling and in the air channel. They also indicate that the Trombe wall with PCM tends to prevent large fluctuations in room temperature and airflow rate. More importantly, it is determined that under constant radiation flux and ambient temperature, the PCM significantly improves the thermal performance of the envelope and effectively shifts the heating load, but under diurnally transient solar radiation flux and ambient tem-perature, these benefits seem less evident. Accordingly, caution must be exercised in extrapolating results obtained under constant ambient conditions to situations involving transient ambient conditions. (c) 2023 Elsevier B.V. All rights reserved.
引用
收藏
页数:16
相关论文
共 50 条
[1]   Effect of reflective coating on thermal and electrical performances of solar roof tiles [J].
Alim, Mohammad A. ;
Tao, Zhong ;
Saeed, Nariman ;
Hao, Xiaojing ;
Abden, Md Jaynul ;
Rahman, Ataur .
ENERGY CONVERSION AND MANAGEMENT, 2022, 270
[2]   Enhancement of natural convection for improvement of Trombe wall performance. An experimental study [J].
Bairi, A. ;
Martin-Garin, A. ;
Adeyeye, K. ;
She, K. ;
Millan-Garcia, J. A. .
ENERGY AND BUILDINGS, 2020, 211
[3]   CFD analyses for passive house with Trombe wall and impact to energy demand [J].
Bajc, Tamara ;
Todorovic, Maja N. ;
Svorcan, Jelena .
ENERGY AND BUILDINGS, 2015, 98 :39-44
[4]   An innovative Trombe wall as a passive heating system for a building in Athens-A comparison with the conventional Trombe wall and the insulated wall [J].
Bellos, Evangelos ;
Tzivanidis, Christos ;
Zisopoulou, Eleni ;
Mitsopoulos, Georgios ;
Antonopoulos, Kimon A. .
ENERGY AND BUILDINGS, 2016, 133 :754-769
[5]   EXPERIMENTAL COMPARISON OF LATENT AND SENSIBLE HEAT THERMAL WALLS [J].
BENARD, C ;
BODY, Y ;
ZANOLI, A .
SOLAR ENERGY, 1985, 34 (06) :475-487
[6]   A study on the effects of double skin facades on the energy management in buildings [J].
Chou, S. K. ;
Chua, K. J. ;
Ho, J. C. .
ENERGY CONVERSION AND MANAGEMENT, 2009, 50 (09) :2275-2281
[7]   Performance and influence of numerical sub-models on the CFD simulation of free and forced convection in double-glazed ventilated facades [J].
Coussirat, M. ;
Guardo, A. ;
Jou, E. ;
Egusquiza, E. ;
Cuerva, E. ;
Alavedra, P. .
ENERGY AND BUILDINGS, 2008, 40 (10) :1781-1789
[8]   Numerical optimization for the design of living walls in the Mediterranean climate [J].
De Masi, Rosa Francesca ;
de Ross, Filippo ;
Ruggiero, Silvia ;
Vanoli, Giuseppe Peter .
ENERGY CONVERSION AND MANAGEMENT, 2019, 195 :573-586
[9]   A comparative study of the CFD modeling of a ventilated active fa ade including phase change materials [J].
Diarce, G. ;
Campos-Celador, A. ;
Martin, K. ;
Urresti, A. ;
Garcia-Romero, A. ;
Sala, J. M. .
APPLIED ENERGY, 2014, 126 :307-317
[10]   Experimental study on thermal performance of an integrated PCM Trombe wall [J].
Duan, Shuangping ;
Wang, Lin ;
Zhao, Zhiqiang ;
Zhang, Chengwang .
RENEWABLE ENERGY, 2021, 163 :1932-1941