Assessment of microcirculatory alteration by a vascular occlusion test using near-infrared spectroscopy in pediatric cardiac surgery: effect of cardiopulmonary bypass

被引:0
|
作者
Savluk, Omer Faruk [1 ,3 ]
Yilmaz, Abdullah Arif [2 ]
Yavuz, Yasemin [1 ]
Arisut, Seda [1 ]
Isildak, Fatma Ukil [1 ]
Karaagac, Aysu Turkmen [1 ]
Ozbek, Baburhan [2 ]
Cine, Nihat [2 ]
Tuncer, Eylem [2 ]
Ceyran, Hakan [2 ]
机构
[1] Kartal Kosuyolu High Educ & Training Hosp, Anesthesiol & Reanimat Clin, Istanbul, Turkiye
[2] Kartal Kosuyolu High Educ & Training Hosp, Pediat Cardiac Surg Clin, Istanbul, Turkiye
[3] Kartal Kosuyolu High Educ & Training Hosp, Anesthesiol & Reanimat Clin, Denizer Str Cevizli Kartal, TR-34865 Istanbul, Turkiye
关键词
Microcirculation; vascular occlusion test; near-infrared spectroscopy; pediatric cardiopulmonary bypass; congenital cardiac surgery; MICROVASCULAR REACTIVITY; OXYGEN-SATURATION; TISSUE; PERFUSION; DYSFUNCTION; PATIENT;
D O I
10.1080/17434440.2024.2306155
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objectives: Cardiopulmonary bypass cause microcirculatory alterations. Near infrared spectroscopic measurement of tissue oxygen saturation and vascular occlusion test are novel technologies for assessing the microcirculatory function of peripheral tissue specifically in patients undergoing cardiac surgery with cardiopulmonary bypass.Our study aimed to evaluate dynamic microcirculatory function using the vascular occlusion testing during cardiac surgery in pediatric patients.Methods: 120 pediatric patients were scheduled. Children had continuous regional oxygen saturation monitoring using near infrared spectroscopy and vascular occlusion test. Vascular occlusion test was performed five times; before induction (T1), after induction (T2), then during cardiopulmonary bypass with full flow (T3), after the termination of CPB (T4) and after sternum closure (T5).Results: Basal value was the lowest at T3 and this value was significantly different among measurements (p < 0,01).Values for maximum and minimum tissue oxygen saturation were the lowest at T3 (83,4 and 52,9%).The occlusion slope varied significantly among measurements (p < 0,01).Reperfusion slopes were significantly different among measurements (p < 0,01) with a further progressive decrease in reperfusion slope with duration of cardiopulmonary bypass.Conclusion: Microcirculatory function can assessed using VOT with forearm Near-infrared spectroscopy derived variables during cardiopulmonary bypass in pediatric cardiac surgery. Noninvasive assessment of microcirculatory perfusion during cardiopulmonary bypass can further help evaluate and improve circulatory support techniques.
引用
收藏
页码:249 / 255
页数:7
相关论文
共 50 条
  • [1] Near-Infrared Spectroscopy and Vascular Occlusion Test for Predicting Clinical Outcome in Pediatric Cardiac Patients: A Prospective Observational Study
    Lee, Ji-Hyun
    Jang, Young-Eun
    Song, In-Kyung
    Kim, Eun-Hee
    Kim, Hee-Soo
    Kim, Jin-Tae
    PEDIATRIC CRITICAL CARE MEDICINE, 2018, 19 (01) : 32 - 39
  • [2] The use of a vascular occlusion test combined with near-infrared spectroscopy in perioperative care: a systematic review
    Niezen, C. K.
    Massari, D.
    Vos, J. J.
    Scheeren, T. W. L.
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2022, 36 (04) : 933 - 946
  • [3] Effect of near-infrared spectroscopy on postoperative delirium in cardiac surgery with cardiopulmonary bypass: a systematic review and meta-analysis
    Sun, Qian
    Wu, Weiguo
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2024, 11
  • [4] Near-infrared spectroscopy combined with vascular occlusion test to predict acute kidney injury in patients undergoing cardiac surgery: a prospective observational study
    Peng, Ling
    Zheng, Yeying
    Guo, Fei
    Su, Mengdan
    Wei, Wei
    JOURNAL OF CARDIOTHORACIC SURGERY, 2025, 20 (01)
  • [5] Use of near-infrared spectroscopy during a vascular occlusion test to assess the microcirculatory response during fluid challenge
    Futier, Emmanuel
    Christophe, Sebastien
    Robin, Emmanuel
    Petit, Antoine
    Pereira, Bruno
    Desbordes, Jacques
    Bazin, Jean-Etienne
    Vallet, Benoit
    CRITICAL CARE, 2011, 15 (05): : R214
  • [6] A Novel Assessment of Peripheral Tissue Microcirculatory Vasoreactivity Using Vascular Occlusion Testing During Cardiopulmonary Bypass
    Smith, Ryan S.
    Murkin, John M.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2014, 28 (05) : 1217 - 1220
  • [7] Near-infrared spectroscopy-based microcirculatory assessment in acute atrial fibrillation
    Barrett, O. S. H.
    Macdonald, S. P. J.
    Playford, D. A.
    ANAESTHESIA AND INTENSIVE CARE, 2015, 43 (01) : 105 - 110
  • [8] Evaluation of different near-infrared spectroscopy technologies for assessment of tissue oxygen saturation during a vascular occlusion test
    Steenhaut, Kevin
    Lapage, Koen
    Bove, Thierry
    De Hert, Stefan
    Moerman, Annelies
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2017, 31 (06) : 1151 - 1158
  • [9] Evaluation of different near-infrared spectroscopy technologies for assessment of tissue oxygen saturation during a vascular occlusion test
    Kevin Steenhaut
    Koen Lapage
    Thierry Bové
    Stefan De Hert
    Annelies Moerman
    Journal of Clinical Monitoring and Computing, 2017, 31 : 1151 - 1158
  • [10] The use of a vascular occlusion test combined with near-infrared spectroscopy in perioperative care: a systematic review
    C. K. Niezen
    D. Massari
    J. J. Vos
    T. W. L. Scheeren
    Journal of Clinical Monitoring and Computing, 2022, 36 : 933 - 946