TraHGR: Transformer for Hand Gesture Recognition via Electromyography

被引:20
作者
Zabihi, Soheil [1 ]
Rahimian, Elahe [2 ]
Asif, Amir [3 ]
Mohammadi, Arash [2 ]
机构
[1] Concordia Univ, Dept Elect & Comp Engn, Montreal, PQ H3G 2W1, Canada
[2] Concordia Univ, Concordia Inst Informat Syst Engn CIISE, Montreal, PQ H3G 2W1, Canada
[3] York Univ, Dept Elect Engn & Comp Sci, Toronto, ON M3J 1P3, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Feature extraction; Transformers; Gesture recognition; Task analysis; Convolutional neural networks; Computer architecture; Electrodes; Electromyogram (EMG); deep neural networks (DNNs); machine learning (ML); transformers; prosthetic; classification; hand gesture; SURFACE EMG; PATTERN-RECOGNITION; SEMG; ROBUST; EXTRACTION; CHANNEL; NUMBER;
D O I
10.1109/TNSRE.2023.3324252
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Deep learning-based Hand Gesture Recognition (HGR) via surface Electromyogram (sEMG) signals have recently shown considerable potential for development of advanced myoelectric-controlled prosthesis. Although deep learning techniques can improve HGR accuracy compared to their classical counterparts, classifying hand movements based on sparse multichannel sEMG signals is still a challenging task. Furthermore, existing deep learning approaches, typically, include only one model as such can hardly extract representative features. In this paper, we aim to address this challenge by capitalizing on the recent advances in hybrid models and transformers. In other words, we propose a hybrid framework based on the transformer architecture, which is a relatively new and revolutionizing deep learning model. The proposed hybrid architecture, referred to as the Transformer for Hand Gesture Recognition (TraHGR), consists of two parallel paths followed by a linear layer that acts as a fusion center to integrate the advantage of each module. We evaluated the proposed architecture TraHGR based on the commonly used second Ninapro dataset, referred to as the DB2. The sEMG signals in the DB2 dataset are measured in real-life conditions from 40 healthy users, each performing 49 gestures. We have conducted an extensive set of experiments to test and validate the proposed TraHGR architecture, and compare its achievable accuracy with several recently proposed HGR classification algorithms over the same dataset. We have also compared the results of the proposed TraHGR architecture with each individual path and demonstrated the distinguishing power of the proposed hybrid architecture. The recognition accuracies of the proposed TraHGR architecture for the window of size 200ms and step size of 100ms are 86.00%, 88.72%, 81.27%, and 93.74%, which are 2.30%, 4.93%, 8.65%, and 4.20% higher than the state-of-the-art performance for DB2 (49 gestures), DB2-B (17 gestures), DB2-C (23 gestures), and DB2-D (9 gestures), respectively.
引用
收藏
页码:4211 / 4224
页数:14
相关论文
共 60 条
[31]   Myoelectric Control of Artificial Limbs-Is There a Need to Change Focus? [J].
Jiang, Ning ;
Dosen, Strahinja ;
Mueller, Klaus-Robert ;
Farina, Dario .
IEEE SIGNAL PROCESSING MAGAZINE, 2012, 29 (05) :147-150
[32]   The effect of arm position on classification of hand gestures with intramuscular EMG [J].
Jochumsen, Mads ;
Waris, Asim ;
Kamavuako, Ernest Nlandu .
BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2018, 43 :1-8
[33]  
Khushaba RN, 2012, I C CONT AUTOMAT ROB, P1534, DOI 10.1109/ICARCV.2012.6485374
[34]   A Subject-Transfer Framework Based on Single-Trial EMG Analysis Using Convolutional Neural Networks [J].
Kim, Keun-Tae ;
Guan, Cuntai ;
Lee, Seong-Whan .
IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2020, 28 (01) :94-103
[35]   Subject-Independent sEMG Pattern Recognition by Using a Muscle Source Activation Model [J].
Kim, Minjae ;
Chung, Wan Kyun ;
Kim, Keehoon .
IEEE ROBOTICS AND AUTOMATION LETTERS, 2020, 5 (04) :5175-5180
[36]  
Kingma DP, 2014, ADV NEUR IN, V27
[37]  
Krishna G, 2020, Arxiv, DOI [arXiv:2001.00501, 10.48550/arXiv.2001.00501]
[38]   PCA and deep learning based myoelectric grasping control of a prosthetic hand [J].
Li, Chuanjiang ;
Ren, Jian ;
Huang, Huaiqi ;
Wang, Bin ;
Zhu, Yanfei ;
Hu, Huosheng .
BIOMEDICAL ENGINEERING ONLINE, 2018, 17
[39]   Transradial Amputee Gesture Classification Using an Optimal Number of sEMG Sensors: An Approach Using ICA Clustering [J].
Naik, Ganesh R. ;
Al-Timemy, Ali H. ;
Nguyen, Hung T. .
IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2016, 24 (08) :837-846
[40]   Improving robustness against electrode shift of high density EMG for myoelectric control through common spatial patterns [J].
Pan, Lizhi ;
Zhang, Dingguo ;
Jiang, Ning ;
Sheng, Xinjun ;
Zhu, Xiangyang .
JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2015, 12