Benefit-to-radiation-risk of low-dose computed tomography lung cancer screening

被引:3
|
作者
Hendrick, R. Edward [1 ,3 ]
Smith, Robert A. [2 ]
机构
[1] Univ Colorado, Sch Med, Dept Radiol, Anschutz Med Campus, Aurora, CO USA
[2] Amer Canc Soc, Early Canc Detect Sci, Kennesaw, GA USA
[3] 3920 Bidens Gate Dr, Timnath, CO 80547 USA
关键词
benefit-to-risk; computed tomography; deaths averted; lung cancer; lung cancer screening; radiation risks; IONIZING-RADIATION; CHEST CT; EXPOSURE; MORTALITY;
D O I
10.1002/cncr.34855
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
BackgroundThe US National Lung Screening Trial (NLST) and Dutch-Belgian NELSON randomized controlled trials have shown significant mortality reductions from low-dose computed tomography (CT) lung cancer screening (LCS). NLST, ITALUNG, and COSMOS trials have provided detailed dosimetry data for LCS.MethodsLCS trial mortality benefit results, organ dose and effective dose data, and Biological Effects of Ionizing Radiation, Report VII (BEIR VII) organ dose-to-cancer-mortality risk data are used to estimate benefit-to-radiation-risk ratios of the NLST, ITALUNG, and COSMOS trials. Data from those trials also are used to estimate benefit-to-radiation-risk ratios for longer-term LCS corresponding to scenarios recommended by United States Preventive Services Task Force and the American Cancer Society.ResultsIncluding only screening doses, NLST benefit-to-radiation-risk ratios are 12:1 for males, 19:1 for females, and 16:1 overall. Including both screening and estimated follow-up doses, benefit-to-radiation-risk ratios for NLST are 9:1 for males, 13:1 for females, and 12:1 overall. For the ITALUNG trial, the benefit-to-radiation-risk ratio is 58-63:1. For the COSMOS trial, assuming sex-specific mortality benefits like those of the NELSON trial, the benefit-to-radiation-risk ratio is 23:1. Assuming a conservative 20% mortality benefit, annual screening in people 50-79 years old with a 20+ pack-year history of smoking has benefit-to-radiation-risk ratios of 23:1 (with follow-up doses adding 40% to screening doses) to 29:1 (with follow-up adding 10%) based on COSMOS dose data.ConclusionsBased on linear, no threshold BEIR VII dose-risk estimates, benefit-to-radiation-risk ratios for LCS are highly favorable. Results emphasize the importance of using modern CT technologies, maintaining low diagnostic follow-up rates, and minimizing both screening and diagnostic follow-up doses.Plain Language SummaryThe benefits of lung cancer screening significantly outweigh estimates of future harms associated with exposure to radiation during screening and diagnostic follow-up examinations.Our findings emphasize the importance of lung cancer screening practices using state-of-the-art computed tomography scanners and specialized low-dose lung screening and diagnostic follow-up techniques. Based on linear, no threshold estimates of cancer risks due to ionizing radiation, benefit-to-radiation-risk ratios are highly favorable for recent lung cancer screening trials and current low-dose computed tomography lung cancer screening. Results emphasize the importance of using modern computed tomography technologies, maintaining low diagnostic follow-up rates, and minimizing both screening and diagnostic follow-up radiation doses.
引用
收藏
页码:216 / 223
页数:8
相关论文
共 50 条
  • [1] Lung Cancer Screening with Low-Dose Computed Tomography
    Chiles, Caroline
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2014, 52 (01) : 27 - +
  • [2] Lung Cancer Screening: Use of Low-Dose Computed Tomography
    Martinez Perez, Encarnacion
    de Aguiar Quevedo, Karol
    Arraras Martinez, Miguel
    Cruz Mojarrieta, Julia
    Fernandez de Moya, Estanislao Arana
    Barrios Benito, Maria
    Hinarejos Parga, Susana
    Cervera Deval, Jose
    Penalver Cuesta, Juan Carlos
    ARCHIVOS DE BRONCONEUMOLOGIA, 2019, 55 (10): : 526 - 531
  • [3] Screening for lung cancer with low-dose computed tomography
    Diederich, S
    Wormanns, D
    Heindel, W
    RADIOLOGE, 2001, 41 (03): : 256 - 260
  • [4] Lung cancer screening with low-dose computed tomography
    Seijo Maceiras, Luis M.
    MEMO-MAGAZINE OF EUROPEAN MEDICAL ONCOLOGY, 2014, 7 (01) : 6 - 9
  • [5] Lung cancer screening with low-dose computed tomography
    Luis M. Seijo Maceiras
    memo - Magazine of European Medical Oncology, 2014, 7 (1) : 6 - 9
  • [6] Lung Cancer Screening with Low-Dose CT: Radiation Risk and Benefit-Risk Assessment for Different Screening Scenarios
    Nekolla, Elke A.
    Brix, Gunnar
    Griebel, Juergen
    DIAGNOSTICS, 2022, 12 (02)
  • [7] Radiation Exposure to Low-Dose Computed Tomography for Lung Cancer Screening: Should We Be Concerned?
    Pozzessere, Chiara
    von Garnier, Christophe
    Beigelman-Aubry, Catherine
    TOMOGRAPHY, 2023, 9 (01) : 166 - 177
  • [8] Low-Dose Computed Tomography for Lung Cancer Screening: The Protocol and The Dose
    McDermott, Shaunagh
    Kaira, Mannudeep K.
    SEMINARS IN ROENTGENOLOGY, 2017, 52 (03) : 132 - 136
  • [9] Barriers to Lung Cancer Screening With Low-Dose Computed Tomography
    Lei, Fang
    Lee, Eunice
    ONCOLOGY NURSING FORUM, 2019, 46 (02) : E60 - E71
  • [10] The role of low-dose computed tomography in lung cancer screening
    Agh Tamas
    Szilberhorn Laszlo
    Csanadi Marcell
    Szeles Gyorgy
    Voko Zoltan
    Adam Gabor
    Kallai Arpad
    ORVOSI HETILAP, 2022, 163 (37) : 1464 - 1471