Coupling PCM wallboard utilization with night Ventilation: Energy efficiency and overheating risk in office buildings under climate change impact

被引:9
|
作者
Tamer, Tolga [1 ]
Dino, Ipek Gursel [2 ]
Baker, Derek K. [3 ,4 ]
Akgul, Cagla Meral [5 ]
机构
[1] Middle East Tech Univ, Dept Micro & Nano Technol, TR-06800 Ankara, Turkiye
[2] Middle East Tech Univ, Dept Architecture, TR-06800 Ankara, Turkiye
[3] Middle East Tech Univ, Dept Mech Engn, TR-06800 Ankara, Turkiye
[4] ODTU Ctr Solar Energy Res & Applicat ODTU GUNAM, TR-06800 Ankara, Turkiye
[5] Middle East Tech Univ, Dept Civil Engn, TR-06800 Ankara, Turkiye
关键词
Climate change; Phase change materials; Office buildings; Night ventilation; Occupant thermal comfort; Building energy consumption; PHASE-CHANGE MATERIALS; THERMAL COMFORT; STORAGE; PERFORMANCE; SIMULATION; MODELS; SYSTEM; OPTIMIZATION; REDUCTION; ENVELOPE;
D O I
10.1016/j.enbuild.2023.113482
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The rising population and increasing thermal comfort expectations are expected to exacerbate the already high HVAC use in offices, which unavoidably places a strain on energy supply systems. Storing thermal energy by incorporating phase change materials (PCMs) is an effective method for improving the buildings' energy efficiency. Understanding how a PCM wallboard responds to climate change (CC) is crucial to maintaining its viability and effectiveness in achieving energy efficiency and sustainability goals during a building's lifetime. This study presents a methodological framework to assess the performance of a building utilizing PCM wallboards in terms of cooling/heating energy demand (and corresponding GWP and operation cost) and occupant thermal comfort considering the changing climate. As a case study, a hypothetical office building located in a cold semi-arid climate with high diurnal fluctuations was selected, and the performance of offices orienting in different directions was evaluated when PCM wallboards with different melting ranges were utilized. PCM19 with a melting range close to heating set point reduced the heating demand by 5.0-7.4% for 2020 and 7.8-9.2% for 2050; while PCM25 with a melting range close to cooling set point yielded cooling reductions of 1.9-4.3% for 2020 and 0.7-2.4% 2050. However, PCM19 and PCM25 were ineffective in cooling and heating, respectively, as they were not compatible with the chosen set points. Coupling PCM25 with night-ventilation (NV) significantly enhanced the cooling savings (NV: 23.2-25.7% for 2020; 13.9-15.7% for 2050; NV + PCM25: 29.4-30.6% for 2020; 16.6-17.5% for 2050); though, the effectiveness of NV was impaired with rising night temperatures due to CC. Hourly energy analysis demonstrated varying performance of wallboards based on the time of day, suggesting potential benefits in supply-demand dynamics and time-of-use energy pricing. In naturally-ventilated scenarios, PCM utilization was ineffective in reducing indoor overheating risk, even when night-ventilation was introduced. Results highlight that to effectively mitigate indoor overheating risk in office buildings, PCM wallboards should be coupled with air-conditioning and night-ventilation. Furthermore, for a comprehensive evaluation of the energy/GWP/cost saving potential of a PCM wallboard during a building's lifetime, not only the current but also the projected local climate should be considered given the shifting energy demand towards cooling due to climate change. Overall, this study provides valuable insights into effective PCM wallboard utilization and lays the groundwork for enhancing the resilience of built environments in the face of climate change challenges.
引用
收藏
页数:19
相关论文
共 28 条
  • [21] Overheating Risk and Energy Demand of Nordic Old and New Apartment Buildings during Average and Extreme Weather Conditions under a Changing Climate
    Velashjerdi Farahani, Azin
    Jokisalo, Juha
    Korhonen, Natalia
    Jylha, Kirsti
    Ruosteenoja, Kimmo
    Kosonen, Risto
    APPLIED SCIENCES-BASEL, 2021, 11 (09):
  • [22] Energy savings and overheating risk of deep energy renovation of a multi-storey residential building in a cold climate under climate change
    Tettey, Uniben Yao Ayikoe
    Gustavsson, Leif
    ENERGY, 2020, 202 (202)
  • [23] Impact of climate change on energy uses and CO2 emissions from office buildings in Australia
    Guan, Lisa
    Proceedings of CRIOCM 2006 International Research Symposium on Advancement of Construction Management and Real Estate, Vols 1 and 2, 2006, : 83 - 90
  • [24] Thermal comfort enhancement of office buildings located under warm and humid climate through phase change material and insulation coupled with natural ventilation
    Arumugam, Pappu
    Ramalingam, Velraj
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2024, 63
  • [25] Impact of climate change on energy saving potentials of natural ventilation and ceiling fans in mixed-mode buildings
    Bamdad, Keivan
    Matour, Soha
    Izadyar, Nima
    Omrani, Sara
    Building and Environment, 2022, 209
  • [26] Potential retrofits in office buildings located in harsh Northern climate for better energy efficiency, cost effectiveness, and environmental impact
    Teamah, Hebatallah Mohamed
    Kabeel, A. E.
    Teamah, Mohamed
    PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2022, 162 : 124 - 133
  • [27] A preliminary impact assessment of typhoon wind risk of residential buildings in Japan under future climate change
    Nishijima, Kazuyoshi
    Maruyama, Takashi
    Graf, Mathias
    HYDROLOGICAL RESEARCH LETTERS, 2012, 6 : 23 - 28
  • [28] Analyzing the Spatial Patterns and Impact Factors of Vegetation Net Primary Productivity and Precipitation Utilization Efficiency in Heilongjiang Province Under Climate Change
    Dong, Fangli
    Mu, Xinglong
    Meng, Fanxiang
    Zheng, Ennan
    Li, Tianxiao
    Zhang, Hengfei
    Jiang, Shihao
    WATER, 2024, 16 (24)