Energy and exergy analysis of a novel multi-pressure levels ejector absorption-recompression refrigeration system: Parametric study and optimization

被引:7
作者
Zarei, Ahmad [1 ]
Zamani, Javid [1 ]
Hooshyari, Liya [1 ]
Zaboli, Sohrab [1 ]
机构
[1] KN Toosi Univ Technol, Dept Mech Engn, Tehran, Iran
关键词
Absorption; recompression; Thermodynamics; COP; Optimization; Ejector; ORGANIC RANKINE-CYCLE; WORKING FLUIDS; PERFORMANCE EVALUATION; COOLING CYCLE; FLASH TANK; NH3-H2O; DESIGN; INTEGRATION; ENHANCEMENT; TEMPERATURE;
D O I
10.1016/j.tsep.2023.101904
中图分类号
O414.1 [热力学];
学科分类号
摘要
The world is facing a cooling crunch, and investing in the efficiency enhancement of cooling systems is the most straightforward strategy to mitigate greenhouse gas (GHG) emissions and reduce costs. To this end, this study primarily sought to enhance the efficiency of an absorption refrigeration cycle (ARC) and diminish energy consumption. For this, a vapor compression refrigeration cycle and an ejector-ARC were combined, using a turbo-expander to improve system efficiency. The ejector would be exploited to raise the absorber pressure and reduce pump power, the turbo-expander was employed in place of the expansion valve, and the compressor was partially used to supply generator heat. The proposed system has four pressure levels. The condenser and generator were assumed to be an integrated unit whose heat loss would be used to heat the generator. The effects of several parameters, e.g., generator temperature and pressure, compressor pressure ratio, and ejector parameters, on the coefficient of performance (COP) and exergetic efficiency (ECOP), were explored. The multiobjective optimization showed that the proposed system had much higher performance than the ARC, with up to 191.2% and 54.7% higher COP and ECOP, respectively. Furthermore, the maximum COP occurred at a generator pressure and temperature lower than the ARC. Thus, the proposed design could handle the high activation temperature and pressure challenges of ARCs with an NH3-H2O working fluid. It was also observed that COP was a function of the ejector mixing tube diameter and had a maximum level. The ejector reduced the circulation ratio and increased the absorber pressure above the evaporator pressure, reducing pump power.
引用
收藏
页数:15
相关论文
共 80 条
[1]   Techno-Economic Analysis of dual ejectors solar assisted combined absorption cooling cycle [J].
Abed, Azher M. ;
Majdi, Hasan Sh. ;
Sopian, K. ;
Ali, Farooq H. ;
Al-Bahrani, Mohammed ;
Al-Amir, Qusay Rasheed ;
Yakoob, Asmaa K. .
CASE STUDIES IN THERMAL ENGINEERING, 2022, 39
[2]   Experimental evaluation of single stage ejector-absorption cooling cycle under different design configurations [J].
Abed, Azher M. ;
Sopian, K. ;
Alghoul, M. A. ;
Majadi, Hasan Sh. ;
Al-Shamani, Ali Najah .
SOLAR ENERGY, 2017, 155 :130-141
[3]   Performance evaluation of flash tank-absorption cooling cycle using two ejectors [J].
Abed, Azher M. ;
Alghoul, M. A. ;
Sopian, K. .
APPLIED THERMAL ENGINEERING, 2016, 101 :47-60
[4]   Performance enhancement of ejector-absorption cooling cycle by re-arrangement of solution streamlines and adding RHE [J].
Abed, Azher M. ;
Alghoul, M. A. ;
Sirawn, R. ;
Al-Shamani, Ali Najah ;
Sopian, K. .
APPLIED THERMAL ENGINEERING, 2015, 77 :65-75
[5]   Review of small-capacity single-stage continuous absorption systems operating on binary working fluids for cooling: Theoretical, experimental and commercial cycles [J].
Altamirano, Amin ;
Le Pierres, Nolwenn ;
Stutz, Benoit .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 106 :350-373
[6]   Experimental and numerical analysis of an air-cooled double-lift NH3-H2O absorption refrigeration system [J].
Aprile, Marcello ;
Toppi, Tommaso ;
Guerra, Marco ;
Motta, Mario .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2015, 50 :57-68
[7]   Quantifying the effect of nanoparticles addition to a hybrid absorption/recompression refrigeration cycle [J].
Babaei, S. Mostafa ;
Razmi, Amir Reza ;
Soltani, M. ;
Nathwani, Jatin .
JOURNAL OF CLEANER PRODUCTION, 2020, 260
[8]   Exergoeconomic analysis and optimization of an Integrated Solar Combined Cycle System (ISCCS) using genetic algorithm [J].
Baghernejad, A. ;
Yaghoubi, M. .
ENERGY CONVERSION AND MANAGEMENT, 2011, 52 (05) :2193-2203
[9]  
Bejan A., 2016, Advanced engineering thermodynamics, DOI [DOI 10.1002/9781119245964, 10.1002/9781119245964]
[10]   Yearly investigation of a solar-driven absorption refrigeration system with ammonia-water absorption pair [J].
Bellos, Evangelos ;
Chatzovoulos, Ion ;
Tzivanidis, Christos .
THERMAL SCIENCE AND ENGINEERING PROGRESS, 2021, 23