Common-path optical coherence tomography guided vertical pneumodissection for DALK

被引:0
|
作者
Wang, Yaning [1 ]
Guo, Shoujing [1 ]
Opfermann, Justin D. [2 ]
Kaluna, James [2 ]
Gensheimer, Bill G. [3 ]
Krieger, Axel [2 ]
Kang, Jin U. [1 ]
机构
[1] Johns Hopkins Univ, Elect & Comp Engn, 3400 North Charles St, Baltimore, MD 21218 USA
[2] Johns Hopkins Univ, Mech Engn, 3400 North Charles St, Baltimore, MD 21218 USA
[3] Dartmouth Hitchcock Med Ctr, 1 Med Ctr Dr, Lebanon, NH 03756 USA
关键词
Optical coherence tomography; optical distal sensor; DALK; DEEP ANTERIOR LAMELLAR; KERATOPLASTY;
D O I
10.1117/12.2650533
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We reported a design and evaluation of an optical coherence tomography (OCT) sensor-integrated 27 gauge vertically inserted razor edge cannula (VIREC) for pneumatic dissection of Descemet's membrane (DM) from the stromal layer. The VIREC was inserted vertically at the apex of the cornea to the desired depth near DM. The study was performed using ex vivo bovine corneas (N = 5) and rabbit corneas (N = 5). A clean penumodissection of a stromal layer was successfully performed using VIREC without any stomal blanching on bovine eyes. The "big bubble" was generated in all five tests without perforation. Only micro bubbles were observed on rabbit eyes. The results proved that VIREC can be an effective surgical option for "big bubble" DALK.
引用
收藏
页数:5
相关论文
共 50 条
  • [41] Motion-Compensated hand-held common-path Fourier-domain optical coherence tomography probe for image-guided intervention
    Huang, Yong
    Song, Cheol
    Liu, Xuan
    Kang, Jin U.
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XVII, 2013, 8571
  • [42] Common-path multimodal optical microscopy
    Yelleswarapu, Chandra S.
    Tipping, Marla
    Kothapalli, Sri-Rajasekhar
    Veraksa, Alexey
    Rao, D. V. G. L. N.
    OPTICS LETTERS, 2009, 34 (08) : 1243 - 1245
  • [43] Motion compensated fiber-optic confocal microscope based on a common-path optical coherence tomography distance sensor
    Huang, Yong
    Zhang, Kang
    Lin, Ching
    Kang, Jin U.
    OPTICAL ENGINEERING, 2011, 50 (08)
  • [44] Comparison of different focusing systems for common-path optical coherence tomography with fiber-optic bundle as endoscopic probe
    Wang, Weichao
    Zhang, Kang
    Ren, Qiushi
    Kang, Jin U.
    OPTICAL ENGINEERING, 2009, 48 (10)
  • [45] Real-Time Surface Tracking Algorithm Used in Common-Path Fourier-Domain Optical Coherence Tomography
    Oh, Yong-Kyun
    Kim, Min-Ho
    Kim, Bang-Young
    Song, Chul Gyu
    Seo, Jeong Hwan
    Kim, Kwan Min
    Kang, Jin
    4TH INTERNATIONAL CONFERENCE ON AWARENESS SCIENCE AND TECHNOLOGY (ICAST 2012), 2012, : 180 - 184
  • [46] Optical coherence tomography distal-sensor guided manual trephine/dissection system for DALK
    Guo, Shoujing
    Wei, Shuwen
    Sarfaraz, Nicolas
    Lee, Soohyun
    Gensheimer, William G.
    Krieger, Axel
    Kang, Jin
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [47] A Fiber-Optic Nerve Stimulation Probe Integrated with a Precise Common-Path Optical Coherence Tomography Distance Sensor
    Zhang, Kang
    Katz, Elizabeth
    Kim, Do-Hyun
    Kang, Jin U.
    Ilev, Ilko K.
    2010 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO) AND QUANTUM ELECTRONICS AND LASER SCIENCE CONFERENCE (QELS), 2010,
  • [48] Development of the Dual Smart Micro-surgical System using Common-path Swept Source Optical Coherence Tomography
    Park, H. C.
    Yeo, C. B.
    Gehlbach, P. L.
    Song, C.
    2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 5 - 8
  • [49] Common-path low-coherence interferometry fiber-optic sensor guided microincision
    Zhang, Kang
    Kang, Jin U.
    JOURNAL OF BIOMEDICAL OPTICS, 2011, 16 (09)
  • [50] Astigmatism Corrected Common Path Probe for Optical Coherence Tomography
    Singh, Kanwarpal
    Yamada, Daisuke
    Tearney, Guillermo
    LASERS IN SURGERY AND MEDICINE, 2017, 49 (03) : 312 - 318