Common-path optical coherence tomography guided vertical pneumodissection for DALK

被引:0
|
作者
Wang, Yaning [1 ]
Guo, Shoujing [1 ]
Opfermann, Justin D. [2 ]
Kaluna, James [2 ]
Gensheimer, Bill G. [3 ]
Krieger, Axel [2 ]
Kang, Jin U. [1 ]
机构
[1] Johns Hopkins Univ, Elect & Comp Engn, 3400 North Charles St, Baltimore, MD 21218 USA
[2] Johns Hopkins Univ, Mech Engn, 3400 North Charles St, Baltimore, MD 21218 USA
[3] Dartmouth Hitchcock Med Ctr, 1 Med Ctr Dr, Lebanon, NH 03756 USA
关键词
Optical coherence tomography; optical distal sensor; DALK; DEEP ANTERIOR LAMELLAR; KERATOPLASTY;
D O I
10.1117/12.2650533
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We reported a design and evaluation of an optical coherence tomography (OCT) sensor-integrated 27 gauge vertically inserted razor edge cannula (VIREC) for pneumatic dissection of Descemet's membrane (DM) from the stromal layer. The VIREC was inserted vertically at the apex of the cornea to the desired depth near DM. The study was performed using ex vivo bovine corneas (N = 5) and rabbit corneas (N = 5). A clean penumodissection of a stromal layer was successfully performed using VIREC without any stomal blanching on bovine eyes. The "big bubble" was generated in all five tests without perforation. Only micro bubbles were observed on rabbit eyes. The results proved that VIREC can be an effective surgical option for "big bubble" DALK.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Quantitative measurements of strain and birefringence with common-path polarization-sensitive optical coherence tomography
    Marvdashti, Tahereh
    Duan, Lian
    Lurie, Kristen L.
    Smith, Gennifer T.
    Ellerbee, Audrey K.
    OPTICS LETTERS, 2014, 39 (19) : 5507 - 5510
  • [22] Common-path optical coherence tomography using a microelectromechanical-system-based endoscopic probe
    Wang, Donglin
    Duan, Can
    Zhang, Xiaoyang
    Yun, Zhao
    Pozzi, Antonio
    Xie, Huikai
    APPLIED OPTICS, 2016, 55 (25) : 6930 - 6935
  • [23] Tissue characterization using axicon probe-assisted common-path optical coherence tomography
    Gupta, Pooja
    Vairagi, Kaushal
    Sharma, Vishal
    Prasad, Kaushal Kishore
    Mondal, Samirk
    OPTICS EXPRESS, 2024, 32 (11): : 20194 - 20206
  • [24] In-fiber common-path optical coherence tomography using a conical-tip fiber
    Tan, K. M.
    Mazilu, M.
    Chow, T. H.
    Lee, W. M.
    Taguchi, K.
    Ng, B. K.
    Sibbett, W.
    Herrington, C. S.
    Brown, C. T. A.
    Dholakia, K.
    OPTICS EXPRESS, 2009, 17 (04): : 2375 - 2384
  • [25] Swept-source common-path optical coherence tomography with a MEMS endoscopic imaging probe
    Duan, Can
    Wang, Donglin
    Zhou, Zhengwei
    Liang, Peng
    Samuelson, Sean R.
    Pozzi, Antonio
    Xie, Huikai
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XVIII, 2014, 8934
  • [26] Common-Path Optical Coherence Tomography Using the Bessel Beam From Negative Axicon Optical Fiber Tip
    Vairagi, Kaushal
    Pandey, Amit
    Gupta, Pooja
    Minz, Rashmi A.
    Tiwari, Umesh K.
    Fick, Jochen
    Mondal, Samir K.
    IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 2019, 25 (01)
  • [27] Truncated Conical-Tip Fiber Probe for Common-Path Optical Coherence Tomography With Optimal Sensitivity
    Wang, Wei
    Ma, Jun
    Guan, Bai-Ou
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2022, 40 (12) : 3974 - 3979
  • [28] Handheld optical coherence tomography scanner using a common-path probing arm with long working distance
    Zhou, Song
    Yang, Wen
    Wang, Yimin
    Chen, Zhong
    Yuan, Tianran
    OPTICS COMMUNICATIONS, 2021, 499
  • [29] Post-tuning of Sample Position in Common-path Swept-source Optical Coherence Tomography
    Park, Jae Seok
    Jeong, Myung Yung
    Kim, Chang-Seok
    JOURNAL OF THE OPTICAL SOCIETY OF KOREA, 2011, 15 (04) : 380 - 385
  • [30] Signal-to-noise ratio analysis of all-fiber common-path optical coherence tomography
    Li, Xiaolu
    Han, Jae-Ho
    Liu, Xuan
    Kang, Jin U.
    APPLIED OPTICS, 2008, 47 (27) : 4833 - 4840