Common-path optical coherence tomography guided vertical pneumodissection for DALK

被引:0
|
作者
Wang, Yaning [1 ]
Guo, Shoujing [1 ]
Opfermann, Justin D. [2 ]
Kaluna, James [2 ]
Gensheimer, Bill G. [3 ]
Krieger, Axel [2 ]
Kang, Jin U. [1 ]
机构
[1] Johns Hopkins Univ, Elect & Comp Engn, 3400 North Charles St, Baltimore, MD 21218 USA
[2] Johns Hopkins Univ, Mech Engn, 3400 North Charles St, Baltimore, MD 21218 USA
[3] Dartmouth Hitchcock Med Ctr, 1 Med Ctr Dr, Lebanon, NH 03756 USA
关键词
Optical coherence tomography; optical distal sensor; DALK; DEEP ANTERIOR LAMELLAR; KERATOPLASTY;
D O I
10.1117/12.2650533
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We reported a design and evaluation of an optical coherence tomography (OCT) sensor-integrated 27 gauge vertically inserted razor edge cannula (VIREC) for pneumatic dissection of Descemet's membrane (DM) from the stromal layer. The VIREC was inserted vertically at the apex of the cornea to the desired depth near DM. The study was performed using ex vivo bovine corneas (N = 5) and rabbit corneas (N = 5). A clean penumodissection of a stromal layer was successfully performed using VIREC without any stomal blanching on bovine eyes. The "big bubble" was generated in all five tests without perforation. Only micro bubbles were observed on rabbit eyes. The results proved that VIREC can be an effective surgical option for "big bubble" DALK.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Downward viewing common-path optical coherence tomography guided hydro-dissection needle for DALK
    Guo, Shoujing
    Opfermann, Justin
    Gensheimer, William G.
    Krieger, Axel
    Kang, Jin U.
    OPTICAL FIBERS AND SENSORS FOR MEDICAL DIAGNOSTICS, TREATMENT AND ENVIRONMENTAL APPLICATIONS XXII, 2022, 11953
  • [2] Common-path Optical Coherence Tomography for Biomedical Imaging and Sensing
    Kang, Jin U.
    Han, Jae-Ho
    Liu, Xuan
    Zhang, Kang
    JOURNAL OF THE OPTICAL SOCIETY OF KOREA, 2010, 14 (01) : 1 - 13
  • [3] Common-path optical coherence tomography guided fibre probe for spatially precise optical nerve stimulation
    Zhang, K.
    Katz, E.
    Kim, D. H.
    Kang, J. U.
    Ilev, I. K.
    ELECTRONICS LETTERS, 2010, 46 (02) : 118 - 119
  • [4] Double common-path interferometer for flexible optical probe of optical coherence tomography
    Park, Jae Seok
    Chen, Zhongping
    Jeong, Myung Yung
    Kim, Chang-Seok
    OPTICS EXPRESS, 2012, 20 (02): : 1102 - 1112
  • [5] Optimization of an angled fiber probe for common-path optical coherence tomography
    Liu, Xuan
    Kang, Jin U.
    OPTICS LETTERS, 2013, 38 (15) : 2660 - 2662
  • [6] Common-path interferometer for frequency-domain optical coherence tomography
    Vakhtin, AB
    Kane, DJ
    Wood, WR
    Peterson, KA
    APPLIED OPTICS, 2003, 42 (34) : 6953 - 6958
  • [7] Long-range common-path spectral domain optical coherence tomography
    Wang, Chen
    Zhang, Qiankun
    Wang, Yimin
    Zhang, Xiangyang
    Zhang, Linna
    OPTICS EXPRESS, 2019, 27 (09): : 12483 - 12490
  • [8] Common-path optical coherence tomography with side-viewing bare fiber probe for endoscopic optical coherence tomography
    Sharma, Utkarsh
    Kang, Jin U.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2007, 78 (11):
  • [9] Common-Path Fourier-Domain Optical Coherence Tomography in Ophthalmology Applications
    Han, Jae-Ho
    Liu, Xuan
    Zhang, Kang
    Kang, Jin U.
    2009 IEEE/NIH LIFE SCIENCE SYSTEMS AND APPLICATIONS WORKSHOP, 2009, : 163 - 166
  • [10] Endoscopic Functional Fourier Domain Common-Path Optical Coherence Tomography for Microsurgery
    Kang, Jin U.
    Han, Jae-Ho
    Liu, Xuan
    Zhang, Kang
    Song, Chul Gyu
    Gehlbach, Peter
    IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 2010, 16 (04) : 781 - 792