Target and untargeted screening of perfluoroalkyl substances in biota using liquid chromatography coupled to quadrupole time of flight mass spectrometry

被引:5
|
作者
Oro-Nolla, B. [1 ]
Dulsat-Masvidal, M. [1 ]
Bertolero, A. [2 ]
Lopez-Antia, A. [1 ]
Lacorte, S. [1 ,3 ]
机构
[1] IDAEA CSIC, Dept Environm Chem, Jordi Girona 18-26, Barcelona 08034, Spain
[2] Assonano Ornitol Picampall Terres Ebre, La Galera 53, Amposta 43870, Spain
[3] IDAEA CSIC, Dept Environm Chem, Jordi Girona 18-26, Barcelona 08034, Catalonia, Spain
关键词
PFAS; Birds; Bioindicators; Time-of-flight; High-resolution mass spectrometry; HERRING GULL EGGS; GREAT-LAKES; ACID; SULFONATE; COLONIES;
D O I
10.1016/j.chroma.2023.464066
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Perfluoroalkyl substances (PFAS) are known to bioaccumulate and trigger adverse effects in marine birds. This study develops an extraction and analytical methodology for the target/untargeted analysis of PFAS in eggs of Yellow-legged gull (Larus michahellis) and Audouin's gull (Larus audouinii) and blood of Greater flamingo (Phoenicopterus roseus), which are used as bioindicators of organic chemical pollution. Samples were extracted by ultrasonication with acetonitrile and cleaned-up with activated carbon, and analysis was performed by ultra-high-performance liquid chromatography coupled to a quadrupole-time of flight mass spectrometer (UHPLC-Q-TOF) with negative electrospray ionization. Data-independent acquisition (DIA) was performed through full-scan acquisition to obtain MS1 at 6 eV and MS2 at 30 eV. In a first step, quantitative analysis of 25 PFAS was performed using 9 mass-labelled internal standard PFAS and quality parameters of the method developed are provided. Then, an untargeted screening workflow is proposed using the high-resolution PFAS library database from NORMAN to identify new chemicals through accu-rate mass measurement of MS1 and MS2 signals. The method permitted to detect several PFAS at concen-trations ranging from 0.45 to 55.2 ng/g wet weight in gull eggs and from 0.75 to 125 ng/mL wet weight in flamingos' blood, with PFOS, PFOA, PFNA , PFUdA , PFTrDA , PFDoA , PFHxS and PFHpA the main com-pounds detected. In addition, perfluoro-p-ethylcyclohexylsulfonic acid (PFECHS, CAS number 646-83-3) and 2-(perfluorohexyl)ethanol (6:2 FTOH, CAS number 647-42-7) were tentatively identified. The devel-oped UHPLC-Q-TOF target/untargeted analytical approach increases the scope of PFAS analysis, enabling a better assessment on contaminant exposure and promoting the use of bird species as bioindicators of chemical pollution.(c) 2023 Published by Elsevier B.V.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] A strategy for untargeted screening of macrolides and metabolites in bass by liquid chromatography coupled to quadrupole orbitrap mass spectrometry
    Jia, Wei
    Shi, Lin
    Chu, Xiaogang
    Chang, James
    Chen, Ying
    Zhang, Feng
    FOOD CHEMISTRY, 2018, 262 : 110 - 117
  • [2] Identification of in vitro metabolites of ethylphenidate by liquid chromatography coupled to quadrupole time-of-flight mass spectrometry
    Negreira, Noelia
    Erratico, Claudio
    van Nuijs, Alexander L. N.
    Covaci, Adrian
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2016, 117 : 474 - 484
  • [3] Mass spectrometric recommendations for Quan/Qual analysis using liquid-chromatography coupled to quadrupole time-of-flight mass spectrometry
    Dubbelman, Anne-Charlotte
    Cuyckens, Filip
    Dillen, Lieve
    Gross, Gerhard
    Vreeken, Rob J.
    Hankemeier, Thomas
    ANALYTICA CHIMICA ACTA, 2018, 1020 : 62 - 75
  • [4] Separation and identification of process-related substances and degradation products in mycophenolate mofetil by liquid chromatography coupled with quadrupole-time of flight mass spectrometry
    Lu, Yu-ting
    Qi, Wen-zhu
    Chen, Yan-fei
    Song, Min
    Hang, Tai-jun
    JOURNAL OF SEPARATION SCIENCE, 2019, 42 (16) : 2650 - 2659
  • [5] Rapid Screening of Fluoroquinolones and Sulfonamides in Dairy Products Using Ultra Performance Liquid Chromatography Coupled to High Resolution Quadrupole Time-of-Flight Mass Spectrometry
    Meng Zhe
    Shi Zhi-Hong
    Lu Yun-Kai
    Sun Han-Wen
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2014, 42 (10) : 1493 - 1500
  • [6] Qualitative analysis of dental material ingredients, composite resins and sealants using liquid chromatography coupled to quadrupole time of flight mass spectrometry
    Vervliet, Philippe
    de Nys, Siemon
    Boonen, Imke
    Duca, Radu Corneliu
    Elskens, Marc
    van Landuyt, Kirsten L.
    Covaci, Adrian
    JOURNAL OF CHROMATOGRAPHY A, 2018, 1576 : 90 - 100
  • [7] Development and validation of an open screening method for doping substances in urine by gas chromatography quadrupole time-of-flight mass spectrometry
    Polet, Michael
    Van Gansbeke, Wim
    Van Eenoo, Peter
    ANALYTICA CHIMICA ACTA, 2018, 1042 : 52 - 59
  • [8] Suspect and non-target screening of reuse water by large-volume injection liquid chromatography and quadrupole time-of-flight mass spectrometry
    Backe, Will J.
    CHEMOSPHERE, 2021, 266
  • [9] Liquid chromatography coupled to quadrupole time-of-flight mass spectrometry (QTOF/MS) assay for quantification of protodioscin in Brachiaria grasses
    Diamantino, Gabriella M. L.
    Biscoto, Gabriela L.
    Pedroza, Heloisa P.
    Amorim, Raimundo Neilson L.
    Keller, Kelly M.
    Melo, Marilia M.
    Soto-Blanco, Benito
    TOXICON, 2018, 155 : 61 - 65
  • [10] Determination of Ginsenosides in Processed Ginseng by Rapid Resolution Liquid Chromatography Coupled with Quadrupole-Time-of-Flight Tandem Mass Spectrometry
    Dai Yu-Lin
    Yue Hao
    Sun Chang-Jiang
    Guo Yun-Long
    Zheng Fei
    Li Jing
    Liu Shu-Ying
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 43 (08) : 1181 - 1186