In-Ear SpO2 for Classification of Cognitive Workload

被引:4
|
作者
Davies, Harry J. [1 ]
Williams, Ian [2 ]
Hammour, Ghena [2 ]
Yarici, Metin [2 ]
Stacey, Michael J. [3 ]
Seemungal, Barry M. [4 ]
Mandic, Danilo P. [2 ]
机构
[1] Imperial Coll London, Dept Elect Engn, London SW7 2AZ, England
[2] Imperial Coll London, Dept Elect & Elect Engn, London SW7 2AZ, England
[3] Royal Ctr Def Med, Acad Dept Mil Med, Birmingham B15 2WB, England
[4] Imperial Coll London, Dept Med, London SW7 2AZ, England
基金
英国工程与自然科学研究理事会;
关键词
Index Terms-Biomedical engineering; biomedical signal pro-cessing; brain-computer interfaces; cognitive processes; pho-toplethysmography; pulse oximeter; random forests; wearable health monitoring systems; TRANSIENT INCREASE; OXYGEN; PERFORMANCE;
D O I
10.1109/TCDS.2022.3196841
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
The brain is the most metabolically active organ in the body, which increases its metabolic activity and, thus, oxygen consumption, with increasing cognitive demand. This motivates us to question whether the increased cognitive workload may be measurable through changes in blood oxygen saturation. To this end, we explore the feasibility of cognitive workload tracking based on in-ear SpO(2) measurements, which are known to be both robust and exhibit minimal delay. We consider a cognitive workload assessment based on an N-back task with a randomized order. It is shown that the 2-back and 3-back tasks (high cognitive workload) yield either the lowest median absolute SpO(2) or largest median decrease in SpO(2) in all of the subjects, indicating a measurable and statistically significant decrease in blood oxygen in response to the increased cognitive workload. This makes it possible to classify the four N-back task categories, over 5-s epochs, with a mean accuracy of 90.6%, using features derived from in-ear pulse oximetry, including SpO(2), pulse rate, and respiration rate. These findings suggest that in-ear SpO(2) measurements provide sufficient information for the reliable classification of cognitive workload over short time windows, which promises a new avenue for real-time cognitive workload tracking.
引用
收藏
页码:950 / 958
页数:9
相关论文
共 50 条
  • [21] THE OYGEN TISSUE SATURATION (SPO2) AUDIT
    Jones, M.
    PEDIATRIC RESEARCH, 2010, 68 : 239 - 239
  • [22] In-Ear Accelerometer-Based Sensor for Gait Classification
    Burgos, Clara Piris
    Gaertner, Lea
    Ballester, Miguel A. Gonzalez
    Noailly, Jerome
    Stoecker, Fabian
    Schonfelder, Martin
    Adams, Tim
    Tassani, Simone
    IEEE SENSORS JOURNAL, 2020, 20 (21) : 12895 - 12902
  • [23] SpO2 and retinopathy of prematurity: state of the art
    Martinelli, Stefano
    Gatelli, Italo
    Proto, Alice
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2012, 25 : 108 - 110
  • [24] Smart Wearable SpO2 Monitor for Newborns
    Datcu, M.
    Luca, C.
    Corciova, C.
    6TH INTERNATIONAL CONFERENCE ON ADVANCEMENTS OF MEDICINE AND HEALTH CARE THROUGH TECHNOLOGY, MEDITECH 2018, 2019, 71 : 41 - 44
  • [25] 100% SpO2: enough is enough...
    Bensalah, M.
    Daban, J. -L.
    Dutasta, F.
    Franck, L.
    Debien, B.
    ANNALES FRANCAISES D ANESTHESIE ET DE REANIMATION, 2013, 32 : A403 - A404
  • [26] Validity of Spo2 in Measuring of Oxygenation Index
    Bilan, Nemat
    Amirikar, Farinaz
    Ghasempour, Masoumeh
    INTERNATIONAL JOURNAL OF PEDIATRICS-MASHHAD, 2016, 4 (06): : 1935 - 1941
  • [27] SPO2探头维修技巧
    汪世清
    宣跃云
    医疗装备, 1999, (01) : 12 - 12
  • [28] SpO2监测用于全麻手术
    蒋佳培,杨静华,卢杰
    临床麻醉学杂志, 1995, (03)
  • [29] SpO2 Alarm: A Tool for Health Care
    Lisset Dominguez-Hernandez, Nancy
    Maria Murrieta-Brigido, Lady
    Samuel Luna-Lozano, Pablo
    VIII LATIN AMERICAN CONFERENCE ON BIOMEDICAL ENGINEERING AND XLII NATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING, 2020, 75 : 548 - 559
  • [30] Development of the device to detect SPO2 in the Field
    Kanaeda, Yoshiaki
    Magatani, Kazushige
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 412 - 415